Re: [AFMUG] Packetflux Syncinjector - safe to run without SiteMonitor

2014-11-24 Thread Josh Luthman via Af
My concern is more operational. I figured it would work, but if problems ever came up would it rally be necessary to have a base. Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337 Troy, OH 45373 On Nov 24, 2014 3:51 AM, "Forrest Christian (List Account) via Af" < af@

Re: [AFMUG] Packetflux Syncinjector - safe to run without SiteMonitor

2014-11-24 Thread Forrest Christian (List Account) via Af
They'll work just fine without a sitemonitor. Early syncinjectors ran standalone. They each had non-microcontroller based timing hardware in them, and adding sitemonitor control added a fair bit of cost. For a brief period, we actually had a version with this added on functionality, which we s

Re: [AFMUG] Packetflux Syncinjector - safe to run without SiteMonitor

2014-11-21 Thread That One Guy via Af
> To: "af@afmug.com" > Subject: [AFMUG] Packetflux Syncinjector - safe to run without SiteMonitor > Date: Fri, Nov 21, 2014 3:17 PM > > > I've never had to power cycle my radios, but if it really came down to it > I could reboot the whole site at the ground. >

Re: [AFMUG] Packetflux Syncinjector - safe to run without SiteMonitor

2014-11-21 Thread CBB - Jay Fuller via Af
Understand Sent from my Verizon Wireless 4G LTE Smartphone - Reply message - From: "Josh Luthman via Af" To: "af@afmug.com" Subject: [AFMUG] Packetflux Syncinjector - safe to run without SiteMonitor Date: Fri, Nov 21, 2014 3:17 PM I've never had to power c

Re: [AFMUG] Packetflux Syncinjector - safe to run without SiteMonitor

2014-11-21 Thread Josh Luthman via Af
You guys drive a hard bargain =/ Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337 Troy, OH 45373 On Fri, Nov 21, 2014 at 4:35 PM, Bill Prince via Af wrote: > Most of the time the just work. So, sure you could probably get by w/o a > SiteMonitor base unit. Howeve

Re: [AFMUG] Packetflux Syncinjector - safe to run without SiteMonitor

2014-11-21 Thread Bill Prince via Af
Most of the time the just work. So, sure you could probably get by w/o a SiteMonitor base unit. However, we have at least one site that loses sync occasionally (very occasionally thankfully). It will drop sync for about 2 seconds once a month or so. We're pretty sure it's just sensitive to t

Re: [AFMUG] Packetflux Syncinjector - safe to run without SiteMonitor

2014-11-21 Thread Josh Luthman via Af
e sync > input status on the aps... > > Sent from my Verizon Wireless 4G LTE Smartphone > > - Reply message - > From: "George Skorup \(Cyber Broadcasting\) via Af" > To: > Subject: [AFMUG] Packetflux Syncinjector - safe to run without SiteMonitor > Date: Fri,

Re: [AFMUG] Packetflux Syncinjector - safe to run without SiteMonitor

2014-11-21 Thread CBB - Jay Fuller via Af
We run several sites without a site monitor and just monitor the sync input status on the aps... Sent from my Verizon Wireless 4G LTE Smartphone - Reply message - From: "George Skorup \(Cyber Broadcasting\) via Af" To: Subject: [AFMUG] Packetflux Syncinjector - safe to r

Re: [AFMUG] Packetflux Syncinjector - safe to run without SiteMonitor

2014-11-21 Thread Josh Luthman via Af
I've never had to power cycle my radios, but if it really came down to it I could reboot the whole site at the ground. I see the advantages but I'm trying to avoid putting any unnecessary gear in the box that's going to be up on the tower. Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1

Re: [AFMUG] Packetflux Syncinjector - safe to run without SiteMonitor

2014-11-21 Thread Josh Baird via Af
How else will you monitor your DC voltages and be able to power cycle your radios if you don't have a Base unit? You can also monitor temperatures in your enclosure with one. > On Nov 21, 2014, at 4:00 PM, Josh Luthman via Af wrote: > > I have a site where I'm providing DC up the tower and wa

Re: [AFMUG] Packetflux Syncinjector - safe to run without SiteMonitor

2014-11-21 Thread George Skorup (Cyber Broadcasting) via Af
Um, yeah, put a base unit in. The DIN rail adapter for the SyncInjector is a separate item. On 11/21/2014 3:00 PM, Josh Luthman via Af wrote: I have a site where I'm providing DC up the tower and want to minimize products up there. Has anyone actually needed to use the SiteMonitor to...monito

[AFMUG] Packetflux Syncinjector - safe to run without SiteMonitor

2014-11-21 Thread Josh Luthman via Af
I have a site where I'm providing DC up the tower and want to minimize products up there. Has anyone actually needed to use the SiteMonitor to...monitor...the sync status and find that information useful? I'm expecting it just simply stays synced and that's the end of it. On a side note I ordere