Have tried applying priority in a policy map an attaching it to the svi?
From: Cliff McGlamry
Sent: Saturday, April 04, 2009 1:45 PM
To: ccie_voice@onlinestudylist.com
Subject: Re: [OSL | CCIE_Voice] How To Configure IP Phone QoS on NM-16ESW
Modulein a Router?
Hi Cliff and Tech,
Thanks for your reply.
I am not sure if the xcode works properly and I made some show to check it.
The xcodes have been registered to ccm and cme successfully.
On cme site:
1. "show call active voice compact"-- It shows the g729 to ccm ip phone address
and g711 to cue ip addr
Young is right
MTP is used to implement features that H.323 doesn't support like hold and
transfer, if you want a MTP to implement this supplementary services check
the box.
2009/4/4 Yung Hung
> I think you only need MTP for supplementary services on H323 version 1**
>
>
>
> *From:* ccie_vo
All paramaters are Auto work or Auto Available there, after an agent
completes a call system puts the agent in Ready mode.
There must be a file that has the parmater ready / not ready. Like the one
in Extension mobility! &doLogout-true !!!
On Sat, Apr 4, 2009 at 2:55 PM, Duy Nguyen wrote:
> I
BlankThanks Cliff,
My goal is to actually configure QoS on incoming and outgoing traffic on the FE
interfaces connected to the IP Phones just like you will do on the ports
connecting to IP Phones on the 6509 or the 3550.
>mls qos trust cos
>switch priority extend cos 0
Takes care of the incomi
I believe you can. Go into Resource group in CRS if I'm not mistaken.
On Sat, Apr 4, 2009 at 12:51 PM, Onur Tufekci wrote:
> Hi All,
>
> Is it possible to put the agents in the ready state automatically right
> after one button login?
>
> Thank you in advance,
>
> Onur.
>
It indeed is a typo. I just made further research and it should be something
like this I check the clock source options on the CVOICE book Third Edition
thanks you very much
for Internal Clock:
1. controller T1 1/0
framing crc4
linecoding hdb3
clock source internal
ds0-group t
I have a requirement to mask the Extn no of the Reception for both the
internal & external caller.
To Explain further for example when Cisco TAC calls the partner Engineer the
no is not displayed it gets displayed as +Call.
Now this was for a External caller.
the same has to be done for Internal ca
Hi gang,
I configured remote user in CUE to contact users on Unity through VPIM:
network location id 100
email domain voip.lab
name "unity"
end location
network location id 200
email domain 10.25.202.2
name "cue"
end location
remote username hqph1 location 100 create
remote username hqph
I think you only need MTP for supplementary services on H323 version 1
From: ccie_voice-boun...@onlinestudylist.com
[mailto:ccie_voice-boun...@onlinestudylist.com] On Behalf Of Jose Gregorio
Linero (jlinero)
Sent: Saturday, April 04, 2009 11:50 AM
To: ccie_voice@onlinestudylist.com
Subject: [OSL
Hello,
I have a question on the internal timing source. I am reading that when you
issue the following command under controller interface mode "clock source
internal", the clock is provided by the local PLL. however on these 2
configuration examples I didn't understand why on the First one the clo
Hi All,
Is it possible to put the agents in the ready state automatically right
after one button login?
Thank you in advance,
Onur.
Hi all,
I am wondering if MTP is a best practice to have it checked in the H323 GW
configuration, or if it is a must.
Appreciate any comments.
Regards,
Jose
BlankThink for a moment about what you are asking.
The priority queue is an outbound queue. With an ESW, it's connected directly
to the router. The priority queue gets put on the serial interface headed out.
There is zero point in putting a priority queue on the inbound side of an
interface.
BlankHi,
I am using a NM-16ESW (16 port FE module) in my branch one 3725 (IOS
12.4(15)T5) Router to connect to my branch one phones; I am finding it
difficult to do everything I have so far taken for granted in a 3550 switchport.
e.g
I want to enable MLS QoS; configure COS-DSCP mapping; reconf
>From your output below, it appears you only have 1 DSP with 16 g711 channels
>and not 16 DSPs.
Tech Guy
- Original Message -
From: Erwan Erwan
To: ccie_voice@onlinestudylist.com ; anil batra
Sent: Wednesday, April 01, 2009 2:40 PM
Subject: Re: [OSL | CCIE_Voice] dspfarm pr
How many PVDM do you have if your router and what are the type?
#sh diag
should give one this information, with that you will be able to calculate the
number of DSPs in your router.
Note:
That PVDM2-16; i.e. 16 channels PVDM version 2 contain only 1 DSP.
As a rule, you cannot configure one DS
I will check the following:
1. Make sure regions on CCM are configured correctly; calls to CME are using
g729.
2. Configure transcoder in CCM and assign it to the device pool.
3. Configure transcoder on the CME and assign it to the telephone-services.
4. Configure 'cisco voice services' to allow
Dead air on a connected call means that the media stream is not in place. This
can be for several reasons:
1. Transcoder at HQ site (if you're using the 6608 blade) is not registered,
not in the correct MRG, MRGL, or location(this is a hidden killer), or using
the WRONG DEFAULT GATEWAY.
2.
Hi all,
There is some trouble.
ccm --> gk --> cme using g729, cme --> cue using g711.
when ccm phone makes a call to cme phone or cue number:
1. call can be connected, but no sound at all.
2. if I change the code (between ccm and cme) to g711, everything is fine.
Why does this happen?
Thanks.
20 matches