Dear Wenhe,
we had a similar case and extraction using CHCl3 plus CH3OH (2:1
ratio, v/v) (65 °C, 30 min) before mass spectrometry worked very well:
https://www.ncbi.nlm.nih.gov/pubmed/21743455
Hope that helps,
Tomas
On Mon, Aug 21, 2017 at 4:41 AM, WENHE ZHONG
Wenhe
Potentially, mass spectrometry in combination with electron capture
dissociation and/or collision-induced dissociation might be helpful. See doi:
10.1007/s13361-013-0662-5.
Best wishes,
Klaus
===
Dr. Klaus Fütterer
Dear Wenhe,
Are there other ligands known for this protein ? Could these be
chemically modified and still interact with your protein ?
Then you could use ligand affinity chromatography to purify your protein
eluting with the same or other ligands.
For me this the only way to obtain
Dear CCP4BB members,
We would like to identify a ligand that is present in crystal structure
(according to strong positive densities at active site) but absent in
crystallization condition. We already have some candidates in mind based on our
knowledges on this protein but we need to validate