Apologies if this has already been covered once before.
Quick question regarding setting up an AGS+ as a frame switch.
Do the cables connecting to the AGS+ have to be DCE in order to get the
frame-relay switching to work, or can it still work if the cables are DTE? I
currently have DTE
tm
-Original Message-
From: Charles Ryan [mailto:[EMAIL PROTECTED]]
Sent: Saturday, July 21, 2001 12:04 AM
To: [EMAIL PROTECTED]
Subject: AGS+ as a frame-relay switch [7:13133]
Apologies if this has already been covered once before.
Quick question regarding setting up an AGS
It doesn't matter which end of the cable is dce, as long as you are using a
dte-dce cable and the dce end is configured with a clock rate.
I have an AGS configured as a frame-relay switch with a csc/4t serial card
and HDv.35 dce to Cisco HD60 Dte cables. I also had difficulty getting
20, 2001 4:10 PM
Subject: RE: AGS+ as a frame-relay switch [7:13133]
http://www.cisco.com/univercd/cc/td/doc/product/core/cisagspl/agshim/69679.h
tm
-Original Message-
From: Charles Ryan [mailto:[EMAIL PROTECTED]]
Sent: Saturday, July 21, 2001 12:04 AM
To: [EMAIL
Did you check the jumper the applique on the AGS+ serial interface to make
it DCE? It was on the webpage that was presented in a previous email.
-e-
- Original Message -
From: Charles Ryan
To:
Sent: Friday, July 20, 2001 2:44 PM
Subject: Re: AGS+ as a frame-relay switch [7:13133
This is exactly the same problem I was seeing before I switched the jumper
on the CSC card for DTe.
-Ejay
-Original Message-
From: Charles Ryan [mailto:[EMAIL PROTECTED]]
Sent: Friday, July 20, 2001 5:28 PM
To: Hire, Ejay; [EMAIL PROTECTED]
Subject: Re: AGS+ as a frame-relay switch [7
In the context of a Frame Relay switch there are two uses of DCE. On the
physical layer DCE refers to the end that requires clocking. On the layer
two or Frame Relay area of the config the FR Switch needs to be identified
as acting as DCE equipment. So a router acting as a Frame Relay Switch can
I have an AGS+ with 8 serial ports running IOS 10.3(6). I'd like to use it
as a frame relay switch.
When I go to a serial interface and try to set the clock rate I get the
following error:
"Setting clockrate for DTE's is not allowed"
Is there a particular version of IOS that I should use?
oller mci/sci"to see what the
ports are configured to.
HTH
Nigel..
- Original Message -
From: John Michalek [EMAIL PROTECTED]
Newsgroups: groupstudy.cisco
To: [EMAIL PROTECTED]
Sent: Thursday, December 21, 2000 6:57 AM
Subject: AGS+ as a Frame Relay Switch
I have an AGS+ with 8 se
9 matches