Re: OT: Error on Cat6500..... [7:29411]

2001-12-18 Thread MADMAN
x27;s site, the Error Message Decoder didn't have anything on this message > in its database... > > -Original Message- > From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]]On Behalf Of > Michael Williams > Sent: Monday, December 17, 2001 6:00 PM > To: [EMAIL PROTECT

RE: OT: Error on Cat6500..... [7:29411]

2001-12-17 Thread Leigh Anne Chisholm
ecoder didn't have anything on this message in its database... -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]]On Behalf Of Michael Williams Sent: Monday, December 17, 2001 6:00 PM To: [EMAIL PROTECTED] Subject: Re: OT: Error on Cat6500. [7:29411] Here's w

Re: OT: Error on Cat6500..... [7:29411]

2001-12-17 Thread Michael Williams
Here's what happened. As I mentioned before, I cleared the NVRAM on both Sups separately. But, when I issued a 'reload' on Sup#1 after clearing, it failed over to Sup#2, and that's when I started getting this error. So, I powered it down, pulled and reseated both Sups, and turned it back on

Re: OT: Error on Cat6500..... [7:29411]

2001-12-17 Thread MADMAN
Funny you mention that. I'm not seeing that particular problem but I have a couple of customers who have seen some strange messages and I cannot find any useful docs on %SYS-SP- or %OIR-SP-, the key here is ANY error messages with -SP-. Hate opening cases cause I can't find simple info but...

OT: Error on Cat6500..... [7:29411]

2001-12-17 Thread Michael Williams
I had a Cat6500 setup in the basement and was using for testing on various things. We moved it up into our Data Center. I wiped NVRAM on both Sup engines (separately), and not it's booted up and running on the Sup in slot 2 (with the Sup in slot 1 (supposedly) in standby mode). >From the consol