Re: Maintenance light

2004-11-02 Thread Huston
2, 2004 12:55 PM Subject: [Norton AntiSpam] Re: Maintenance light On the E250, the "General Error" LED on the front status panel is plumbed to the auxio power LED bit (logical OR, if I recall correctly). If it bothers you, I'd be happy to provide a patch to you. Alternatively,

Re: Maintenance light

2004-11-02 Thread Eric Brower
...I should also mention, dropping to OBP and typing "led-off" then "go" should extinguish the light and get you back to the OS-- that's a simpler workaround ;) E On Tue, 2 Nov 2004 10:55:11 -0700, Eric Brower <[EMAIL PROTECTED]> wrote: > On the E250, the "General Error" LED on the front status

Re: Maintenance light

2004-11-02 Thread Eric Brower
On the E250, the "General Error" LED on the front status panel is plumbed to the auxio power LED bit (logical OR, if I recall correctly). If it bothers you, I'd be happy to provide a patch to you. Alternatively, I have a rough SUNW,envctrtltwo environmental monitoring driver for the E250 I'd be h