Re: [drakelist] Soft start solution for 110v operation

2005-12-17 Thread Jim Shorney
Jim Shorney [EMAIL PROTECTED] made an utterance to the drakelist gang -- On Thu, 15 Dec 2005 10:03:59 -0500 (EST), [EMAIL PROTECTED] wrote: My only concern with thermisters is they increase HV transformer primary winding ESR and

Re: [drakelist] Soft start solution for 110v operation

2005-12-17 Thread R.van Trotsenburg
R.van Trotsenburg [EMAIL PROTECTED] made an utterance to the drakelist gang -- Hi, I use the trick with the relay over the termister successful in my SB1000 amplifier already for a long time. As soon as the 12V from the power

Re: [drakelist] Soft start solution for 110v operation

2005-12-15 Thread K9SQG
[EMAIL PROTECTED] made an utterance to the drakelist gang -- Various sizes of inrush limiters are available from RF Parts... -- Submissions:

Re: [drakelist] Soft start solution for 110v operation

2005-12-15 Thread jsb
[EMAIL PROTECTED] made an utterance to the drakelist gang -- On Wed, 14 Dec 2005, Jim Shorney wrote: All this is partially moot until he's accepting orders but i'd like to prepare now - i'm open to other soft start inrush

[drakelist] Soft start solution for 110v operation

2005-12-14 Thread Jason Buchanan
Jason Buchanan [EMAIL PROTECTED] made an utterance to the drakelist gang -- hi, I've looked at Harbach's SS-100 with interest but i'm wondering how I could put this to use for 110v operation? I want to put a 110v switched

Re: [drakelist] Soft start solution for 110v operation

2005-12-14 Thread Jim Shorney
Jim Shorney [EMAIL PROTECTED] made an utterance to the drakelist gang -- On Wed, 14 Dec 2005 18:07:50 -0500, Jason Buchanan wrote: All this is partially moot until he's accepting orders but i'd like to prepare now - i'm open