Re: [Elecraft] K2: Hi Cur on 30m

2006-12-27 Thread Mike Markowski
Just to close this thread in case anyone was wondering about it, I installed the KPA100UPKT today and it solved the HI CUR on 30m problem. The K2 now draws less than 1.7 A on 30m with 100 W tx into dummy load compared to 4.1 A before. What a nice change. My thanks to Don and the Elecraft Par

RE: [Elecraft] K2: Hi Cur on 30m

2006-12-13 Thread Don Wilhelm
Mike, First, count the number of turns on L4, L5 and L6 in the KPA100 - count the turns that go through the center of the core rather than the outside. An extra turn on these windings would produce the Hi-cur on 30 meters. How old is your KPA100? If the kit was ordered mid-2005, then you may ha

Re: [Elecraft] K2: Hi Cur on 30m

2006-12-13 Thread Mike Markowski
Mike Markowski wrote: ... If anyone has been through this, what do you think - have I possibly zorched my PAs?... That should have said"have I zorched my PA's power transistors?" ___ Elecraft mailing list Post to: Elecraft@mailman.qth.net You mus

[Elecraft] K2: Hi Cur on 30m

2006-12-13 Thread Mike Markowski
I just noticed I'm getting a Hi Cur message only on 30m. The set up: - K2/100 into dummy load (KAT100 disconnected) - Power set to 100 W - CAL CUR set to 3.50 A - When CAL CUR is 4.10 A, current drawn on 30m levels out at 4.02 A - When I drop to 85 to 90 W, 30m draws just under 3.50 A - All othe