Re: [Elecraft] K2 Excessive Current

2005-06-27 Thread Stuart Rohre
In today's ever more crowded circuits; I find that during installation of a component, I should either hold the end of the wire to be cut or put a finger on it, so that it will not "fly" into some part of the circuit and short something. It is safer than nipping ends of wires with the cutters with

[Elecraft] K2 Excessive Current

2005-06-27 Thread m1bnw
To Tom KM4CU Thanks also for your advice Regards Colin m1bnw Thanks for all your advice on my excessive current consumption on my K2. I did eventually find that I had a fault on the Control board in the 8 V Switching circuitry. The FET Q3 had failed and was turning on the 8 volt supply vi

[Elecraft] K2 Excessive Current

2005-06-27 Thread m1bnw
To Jim K4ZM, Don W3FPR, Rolf 0H6KXL & Martin Renardy, Thanks for all your advice on my excessive current consumption on my K2. I did eventually find that I had a fault on the Control board in the 8 V Switching circuitry. The FET Q3 had failed and was turning on the 8 volt supply via Q1 to the