Re: [Elecraft] K2 filter bandwidth versus real bandwidth...

2007-09-20 Thread David Woolley
Steve Kallal wrote: If I want to pass a 500 Hz signal, what bandwidth should I select in the filter calibration? I guess the selected bandwidth isn't measured at 6 db down, or is it? As this is done by open loop control of a varicap control voltage, I'd expect the relationship to vary

Re: [Elecraft] K2 filter bandwidth versus real bandwidth...

2007-09-20 Thread Don Wilhelm
Steve, The numbers displayed for the filter width are not necessarily the actual width of the filter. The actual bandwidth depends on the particular combination of crystals and varactors in your K2. Use Spectrogram to measure the actual width of your filter if you wish to have a precise

[Elecraft] K2 filter bandwidth versus real bandwidth...

2007-09-19 Thread Steve Kallal
I've set up my K2 with the following bandwidths for the RTTY mode: FL1OP1 FL21000 Hz FL3500 Hz FL4250 Hz I am listening to an Olivia signal (a digital mode) with a 500 Hz bandwidth. I would expect FL3 at 500 Hz to pass the whole signal. Instead I have to select FL2 at 1000 Hz