Steve Kallal wrote:
If I want to pass a 500 Hz signal, what bandwidth should I select in the
filter calibration? I guess the selected bandwidth isn't measured at 6 db
down, or is it?
As this is done by open loop control of a varicap control voltage, I'd
expect the relationship to vary
Steve,
The numbers displayed for the filter width are not necessarily the
actual width of the filter. The actual bandwidth depends on the
particular combination of crystals and varactors in your K2.
Use Spectrogram to measure the actual width of your filter if you wish
to have a precise
I've set up my K2 with the following bandwidths for the RTTY mode:
FL1OP1
FL21000 Hz
FL3500 Hz
FL4250 Hz
I am listening to an Olivia signal (a digital mode) with a 500 Hz bandwidth.
I would expect FL3 at 500 Hz to pass the whole signal. Instead I have to
select FL2 at 1000 Hz
3 matches