On Tuesday 11 August 2015 07:58:20 andy pugh wrote:
> On 11 August 2015 at 12:51, Gene Heskett wrote:
> > Thats another possibility Andy, but that one, levered out to flip
> > this bit of Mahogany, would have to be pretty stout in order to make
> > its 45 degrees move the gauge close to 120 degre
On 11 August 2015 at 12:51, Gene Heskett wrote:
> Thats another possibility Andy, but that one, levered out to flip this
> bit of Mahogany, would have to be pretty stout in order to make its 45
> degrees move the gauge close to 120 degrees. Its 3/8" thick, 1.75"
> wide, and about a foot long, swi
On Tuesday 11 August 2015 05:16:55 andy pugh wrote:
> On 11 August 2015 at 01:45, Gene Heskett wrote:
> > Thats tomorrows project, while I am mulling whether or not I make
> > the jig, either air driven to bring it in or out, or, if I can
> > figure out how to drive a cdroms tray motor to flip it
On 11 August 2015 at 01:45, Gene Heskett wrote:
> Thats tomorrows project, while I am mulling whether or not I make the
> jig, either air driven to bring it in or out, or, if I can figure out
> how to drive a cdroms tray motor to flip it down or up electrically.
How about a rotary solenoid?
http:
On Monday 10 August 2015 19:52:51 andy pugh wrote:
> On 11 August 2015 at 00:10, Gene Heskett wrote:
> >> G92.2 - reset axis offsets to zero.
> >
> > This is 'touch offs' only?
>
> No, it is _only_ the G92 offset. (Which you might well not be using)
I think I see. The previous msg was the magic
On 11 August 2015 at 00:10, Gene Heskett wrote:
>> G92.2 - reset axis offsets to zero.
>>
> This is 'touch offs' only?
No, it is _only_ the G92 offset. (Which you might well not be using)
--
atp
If you can't fix it, you don't own it.
http://www.ifixit.com/Manifesto
---
On Monday 10 August 2015 18:15:42 andy pugh wrote:
> On 10 August 2015 at 21:26, Gene Heskett wrote:
> > To be specific, G92.1 is not clearing #5061, the g54 X offset.
> > Possibly not clearing #5062 or #5063, all of which I use to
> > calibrate the machine
>
> Why do you think that it should?
>
On 10 August 2015 at 21:26, Gene Heskett wrote:
> To be specific, G92.1 is not clearing #5061, the g54 X offset. Possibly
> not clearing #5062 or #5063, all of which I use to calibrate the machine
Why do you think that it should?
The Docs say:
G92.1 - reset axis offsets to zero and set paramet
On Monday 10 August 2015 16:26:18 Gene Heskett wrote:
> To be specific, G92.1 is not clearing #5061, the g54 X offset.
> Possibly not clearing #5062 or #5063, all of which I use to calibrate
> the machine
>
> I can code around it as there's nothing to stop me from putting a line
> in the earlier
To be specific, G92.1 is not clearing #5061, the g54 X offset. Possibly
not clearing #5062 or #5063, all of which I use to calibrate the machine
I can code around it as there's nothing to stop me from putting a line in
the earlier code to clear it. It works from the MDI interface.
#5061 = 0.0
10 matches