adapters have an 5x20 IEC fuse some have thermo fuses and many have no
fuse at all.
Do I overlook some exceptions or new requirements, that allows adaptors without
BS fuse, or are they all just "normal" Asian low quality?
Med venlig hilsen / Best regards,
Kim Boll Jensen
Bolls Aps
2
some one point me to some official web pages that makes it clear when we
need an importer/ representative company with address in the UK?
Med venlig hilsen / Best regards,
Kim Boll Jensen
Bolls Aps
22 99 69 91
-
This message
Hi all
We need to upgrade to a better system for calibration handling, but are not
interested in complex SW solutions, just like an improved Excel :-)
Can anyone recommend such a SW?
Med venlig hilsen/Kind regards
Kim Boll Jensen
Bolls Aps
Ved Gadekæret 11F
DK-3660 Stenløse
Hi
I have trouble finding requirements for a baby cradle rocker. The rocker is
at the same time the cradle fixing. The rocker have 2 hooks one for hanging
it from eg. a hook in sealing and the other hook is used to hang the cradle
on. (The cradle is made mostly of fabric and is CE marked).
Sorry for lifting EMC up to a higher level, but some times I really need to
get the devil out of the measurements :-)
Have a nice weekend
Kim Boll
-
This message is from the IEEE Product Safety Engineering Society emc-pstc
tions and for many years ago VDE did have
some rules like that.
Does anyone have some good references on this subject?
Best regards,
Mr. Kim Boll Jensen
-
This message is from the IEEE Product Safety Engineering Societ
fter each
other such as ringing wave form?
Best regards,
Kim Boll Jensen
-
This message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. To post a message to the list, send your e-mail to
Hi all
Regarding especially Li-ion batteries and rechargeable batteries in general.
Battery equipment is not directly under LVD, but under 2001/95/EC General
Product Safety directive we have EN 60950 and EN 60065, which includes
safety of batteries, for some products but also excludes among
Hi all
Does anyone have a good link to some English version of the QCVN 4 list of
mandatory regulation for EEE or just some guide lines for type approval
regulation on EE in Vietnam?
Best regards,
Kim Boll
-
This message
outlets each
with a mains power cord or can a 24 outlet be used.
I think that the following standard could give me the answer but I can only
find the standard NF C 61-314 and NF C 15 100 in French.
Can someone help me closer to an answer?
Best regards,
Mr. Kim Boll Jensen
...@jmwa.demon.co.uk]
Sendt: 9. januar 2015 10:49
Til: EMC-PSTC@LISTSERV.IEEE.ORG
Emne: Re: [PSES] New EU marine directive
In message <005001d02bef$3f10fb40$bd32f1c0$@dk>, dated Fri, 9 Jan 2015, Kim
Boll Jensen writes:
>The old directive 96/98/EU with amendments will be changed into
>2
;-)
Best regards,
Mr. Kim Boll jensen
-
This message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. To post a message to the list, send your e-mail to
All emc-pstc postings are
that den design is not restricted.
But how do I understand the R15 min. The manufacturer does not have R15 at
all, but comply with the R9.5 around mains pins. Is there any good guide for
the layout or are you free to reduce the housing around the ISOD pin?
Beat regards,
Mr. Kim Boll Jensen
le of years that did not comply with the BS
1363.
So my concern is to find the right parts of BS 1363 or a separate standard
that addresses the plug of a wall-plug type equipment.
Best regards,
Mr. Kim Boll Jensen
-Oprindelig meddelelse-
Fra: Boštjan Glavič [mailto:bostjan.gla...@siq.si]
. Kim Boll Jensen
Bolls Aps
Ved Gadekæret 11F
DK-3660 Stenløse
Phone: +45 48 18 35 66
k...@bolls.dk
www.bolls.dk
-
This message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. To post a
standard product and a local transformer manufacturer could not make one for
me. (the primary impedance shall be higher than normal)
Where can I get a tester or a transformer?
Best regards
Mr. Kim Boll Jensen
Bolls Aps
Ved Gadekæret 11F
DK-3660 Stenløse
Phone: +45 48 18 35 66
k
,
Mr. Kim Boll Jensen
Bolls Aps
Ved Gadekæret 11F
DK-3660 Stenløse
Phone: +45 48 18 35 66
k...@bolls.dk
www.bolls.dk
-
This message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. To
. Kim Boll Jensen
Bolls Aps
Ved Gadekæret 11F
DK-3660 Stenløse
Phone: +45 48 18 35 66
k...@bolls.dk
www.bolls.dk
-
This message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. To post a
.
I have put a big effort into finding a good way around EN 60204 but I get
caught by EU guidelines and annexes in the standards.
There must be other companies with the same problem. What do they do?
Best regards,
Mr. Kim Boll Jensen
Bolls Aps
Ved Gadekæret 11F
DK-3660 Stenløse
o all products require the use of a NB?
Is there issued a guide on this regulations
Best regards,
Mr. Kim Boll Jensen
Bolls Aps
Ved Gadekæret 11F
DK-3660 Stenløse
Phone: +45 48 18 35 66
k...@bolls.dk
www.bol
measuring instrument, but how
would US and Canada look at the transportation system?
Best regards,
Mr. Kim Boll Jensen
Bolls Aps
Ved Gadekæret 11F
DK-3660 Stenløse
Phone: +45 48 18 35 66
k...@bolls.dk
www.bolls.dk
connected medical devices shall be designed. It is
absolutly best to make it float, when looking at medical electrical safety.
Best regards,
Mr. Kim Boll Jensen
Bolls Aps
Denmark
Fra: emc-p...@ieee.org [emc-p...@ieee.org] På vegne af Rick Linford
[rlinf
HELP
Im trying to find a good and solid EN 60601-1 3 ed seminar here in EU, but
all seminars I can find is held in the US. Can anyone help me?
Dont misunderstand me, I like the US, but it more convenient for a Dane to
go around in EU ;-)
Best regards,
Mr. Kim Boll Jensen
Bolls
Hi
I think Patty is very correct here. The requirements in 61000-4-2 can be
whatever they want, it is a how to test standard. The product standard
(here 60601-1-2 and -2-xx) is the standard that sets the actual
requirements.
Best regards,
Mr. Kim Boll Jensen
Bolls Aps
Ved
green and yellow colour. Colours of
neutral and POWER SUPPLY CORD conductors shall be in accordance with the
Canadian Electrical Code (CEC), Part I, CSA C22.2 No. 21, and CSA C22.2 No.
49.
Can we use green on a mulit-wire cable?
Best regards,
Mr. Kim Boll Jensen
Bolls Aps
Ved Gadekæret
Hi
Does anyone know where I can find standards/requirements for vibration test
of equipment for mounting in autos especially in EU.
Best regards,
Mr. Kim Boll Jensen
Bolls Rådgivning
Ved Gadekæret 11F
DK-3660 Stenløse
Denmark
T: +45 48 18 35 66
F: +45 48 18 35 30
k...@bolls.dk
www.bolls.dk
Hi all
I have been told that the UL marking on PCB (UR 94V-0 etc.) can also be
something like E4. Does anyone know if the marking requirements have been
changed and if so where I can get more information.
Best regards,
Mr. Kim Boll Jensen
Bolls Rådgivning
Ved Gadekæret 11F
DK-3660 Stenløse
Hi all
Can someone tell me what the test requirements are for Rostest for lab
equipment.
We have the electrical safety part OK, but what about clima and vibration
and EMC.
Where can I find specific data on standards and if accredited test are
required.
Best regards,
Mr. Kim Boll Jensen
Bolls
re)
Best regards,
Mr. Kim Boll Jensen
Bolls Rådgivning
Ved Gadekæret 11F
DK-3660 Stenløse
Denmark
T: +45 48 18 35 66
F: +45 48 18 35 30
k...@bolls.dk
www.bolls.dk
-
This message is from the IEEE Product Safety Engineering Society
emc-pstc discussion list.Website: http://www.ieee-pses.org/
t-current protected such that if a
Shuko
> plug is used and there is a mains to chassis fault, persons will be
> protected?
>
> Richard Woods
> Sensormatic Electronics
> Tyco International
>
>
>
> -Original Message-
> From: Kim Boll Jensen [mailto:k...@bolls.dk
plugs.
4. Some product standards have national deviations which requires a warning
on Schuko connector that the installation shall have a fault current circuit
or a correct grounding plug shall be fitted.
Best regards,
Kim Boll Jensen
Bolls Raadgivning
Denmark
Fra: owner-emc-p
h are restricted. This concerns the following stages:
selling/exporting the sticks
using the sticks in the equipment
waste
The product will be sold in EU and US/Canada.
A good web page with information would be great, but also a good consultant
could be used or any other help.
Best regards,
Kim Boll J
is an Unintentional radiator, the product is
thereby under Verification ( see 15.101 other devices).
Best regards,
Kim Boll Jensen
Bolls Rådgivning
Denmark
Fra: owner-emc-p...@majordomo.ieee.org
[mailto:owner-emc-p...@majordomo.ieee.org]På vegne af Colgan Christopher
[Soundcraft UK]
Sendt: 2
Hi all
Can some one send me a copy of CCA 227-7 Rotine tests for medical equipment,
or point me to a downloadeable fil.
Best regards,
Kim Boll Jensen
Bolls Rådgivning
Hyacintvej 6
DK-3660 Stenløse
Tlf.: 48 18 35 66
Fax: 48 18 35 30
Mobil: 22 99 69 91
E-mail: k...@bolls.dk
web
when not to
register.
(The drives are Class I but includes a higher laser internally as fare
as I know)
Best regards,
Kim Boll Jensen
Bolls Raadgivning
Denmark
Title: FDA registration of laser
Hi all good people
Just a simple question.
When using a CD or DVD driver in a product (PC or
This is a multi-part message in MIME format.
Hi all
Does any one know of other EMC requirements or other coming requirements
for agricultural machines than EN ISO 14982.
Best regards,
Kim Boll Jensen
Bolls Raadgivning
Denmark
Title: Argicultural machines
Hi all
Does any one know of
2 which
are EMC requirements BUT, BUT, BUT the document OJ C 319 does NOT
include 98/79 in its heading, and this list of standards is not included
on the list on the above web page.
What is the right approach ?
Best regards,
Kim Boll Jensen
Bolls Raadgivning
Title: In-vitro
Hi all
I
only under Machinery and EMC directive, but the
customer wants also Low voltage directive to be fulfilled.
Can someone please help me to find the right standards. I have some idea
but I'm not sure.
Best regards,
Kim Boll Jensen
Bolls, Denmark
Title: Cutter
Hi all
I have a product w
o the R&TTE directive 99/5/EC.
Best regards,
Kim Boll Jensen
Bolls Raadgivning
Denmark
k...@bolls.dk
www.bolls.dk
Cheng-Wee Lai skriver:
> Dear All,
>
> Automotive safety is not my field but I have come across this device that
> are maybe some of you can give me some input.
&
Dear Brian
Please indicate where in the standard these references are made, because
it could be that they should have referred to another clause which
exist.
Best regards,
Kim Boll Jensen
Bolls Raadgivning
Denmark
www.bolls.dk
boconn...@t-yuden.com skriver:
>
>
> The index of my c
k you very much.
Best regards,
Kim Boll Jensen
Bolls Raadgivning
Denmark
<>
t any national web.
Best regards,
Kim Boll Jensen
Bolls Raadgivning
Denmark
<>
Hi all
Does anyone have a world wide list over Bluetooth approval requirements
or can point me to a web page with good information. It is not the BT
approval itself but the short range devices approval/requirements I
seek.
Best regards,
Kim Boll Jensen
Bolls Raadgivning
Denmark
<>
mally requires E marking according to directive 95/54/EEC.
Best regards,
Kim Boll Jensen
Bolls Raadgivning
Denmark
<>
eal life communication to seen if you have a problem at all.
>
> Best regards,
>
> Kim Boll Jensen
> Bolls Raadgivning
> Denmark
>
> j...@aol.com skriver:
>
> > In a message dated 10/8/2002, Alex McNeil writes:
> >
> >
> >
> >> As I am in p
think the ampacity can vary from different manufacturers but , does
anyone have some kind of guide concerning ampacity of small signal
cables ?
Best regards,
Kim Boll Jensen
Bolls Raadgivning
Denmark
<>
Hi all
I need a report form like those used in the CB scheme for EN
60601-1-1;2001 and for EN 60601-1 + A1, 2, 12, 13. I can't find anywhere
to buy it.
So could some one help me to get a copy or tell me where to buy them.
Best regards,
Kim Boll Jensen
Bolls Raadgivning
Denmark
<>
/frequency diagram over max. current the the
body can withstand without hazards ? (It is normally used for mains
leakage current protection).
Best regards,
Kim Boll Jensen
Bolls Raadgivning
Denmark
<>
Hi all
I have just got a PMM 8010 and 8030 but without software, I can only
download a WIN update from PMM not the whole software. Can some one help
me with a copy of the original software ?
Best regards,
Kim Boll Jensen
<>
part 15 and ICES 003. It uses timing signals of more that
9.000/10.000 cycles pr. second.
Best regards,
Kim Boll Jensen
Bolls Raadgivning
Denmark
<>
Hi All
Can some one update me with information on the following:
433 MHz SRD and Bluetooth product approval requirements in:
Japan
Korea
Taiwan
Singapore
I need information on both EMC, Radio and Safety.
Best regards,
Kim Boll Jensen
Bolls Raadgivning
<>
? mm
Best regards
Kim Boll Jensen
Bolls Raadgivning
Denmark
<>
ense under part 90 ?
Please help me !
Best regards,
Kim Boll Jensen
Bolls Raadgivning
Denmark
<>
.
Does this product fall under the R&TTE directive ?
According to my interpretation the definitions in art. 2 c) and d) say
that it has to be used for TX to be under this directive.
What do you think ?
Best regards,
Kim Boll Jensen
Bolls Raadgivning
Denmark
<>
Hi I'm sorry if I have confused things a little. But I visited this page:
http://europa.eu.int/comm/enterprise/rtte/implem.htm
And was so naive to think that when it says Adopted there was no national
deviations, sorry.
Best regards,
Kim Boll Jensen
Bolls
"Andre, Pierre-Marie"
Hi Bill
Both Littelfuse and Wickmann Werke have these fuses
Good Luck
Kim Boll Jensen
Bolls Raadgivning, Denmark
Bill Wilson skriver:
> HELP!!! I'm looking for a UL R/C, 250V in line fuseholder for 5X20mm
> &/or .25"X1.25" fuses. There are a lot of 32Volters out t
Hi
Does any one have the DENAN list of electrical equipment which is under
the approval scheme in Japan.
And also information to which standards equipment have to be tested
Best regards,
Kim Boll Jensen
Bolls Raadgivning
<>
Hi all
I have lost my contact with the TREG group, can some one please tell me
how to join again.
Best regards,
Kim Boll Jensen
<>
Hi all
What is the status for Japan concerning both EMC and Elec. safety is it
still voluntary to comply ?
What is the best place to seek information ?
Best regards,
Kim Boll Jensen
<>
Best regards,
Kim Boll Jensen
<>
.
Can some one help me or point me in the right direction.
Best regards,
Kim Boll Jensen
<>
machine, since the fire point is 12 deg. C as far as we can
find.
Have anyone some experience with spirit and know how to handle it ?
Best regards,
Kim Boll Jensen
<>
t use standards which have been outdated.
They told me that there wasn't any official interpretation within EU, so before
we gets too many questions like this I
hope that we can get an official statement.
Best regards,
Kim Boll Jensen
John Woodgate skriver:
> I read in !emc-pstc that Patrick
supports this
statement.
But what about R&TTE when new standards are harmonized where no
standards was before ?
Best regards,
Kim Boll Jensen
Bolls Raadgivning
<>
Hi all
Does anyone know of a marking on a safety interlock switch whitch is a
L in a circle.
I'm looking for a switch which are tested for 100.000 cycles and I
wander if the L marking was some thing like it (but I doubt).
Best regards,
Kim Boll Jensen
Bolls Raadgivning
<>
also put it into the marketing brochures.
Best regards,
Kim Boll Jensen
Bolls Raadgivning
"Bailey, Jeff" skriver:
> Hello group,
>
> I am in the process of defining a test plan for a product that fits nicely
> into the definition of ITE as stated in
> 3.1 of EN55022:1
Hi all
Does anyone know where I can get a list of the material classifications
used in IEC 950 table C.1 concerning temp. limits for motors. It is also
refereed to in UL3101-1/EN 61010-1.
Best regards,
Kim Boll Jensen
<>
ired now)
Best regards,
Kim Boll Jensen
Bolls Raadgivning
wmf...@aol.com skriver:
> Since EN 61326 is a fairly recent vintage, and only _just_ displaced my use
> of EN50082, a couple of re-test questions:
>
> 1) Standard product already tested and 'declared' before EN61326
Hi all
Does anyone know of requirements in Japan for a Class 3b laser product:
electrical safety
EMC
laser safety
Best regards,
Kim Boll Jensen
Bolls Raadgivning
<>
Hi all
Could somebody please send me the basic requirements for CISPR 11
emission limits I need to compare with CISPR 22 for a non radio product
under EN60601-2.
Best regards,
Kim Boll Jensen
Bolls Raadgivning
Consultancy in world wide approvals
<>
just add a label on the product with a text like this:
For evaluation purpose only ?
And what about EU, the manufacturer is located in EU ?
Best regards,
Kim Boll Jensen
Bolls Raadgivning
Consultant in type approvals
---
This message is from the IEEE E
mited only for industrial use.
The last solution is normally not good because who knows if customers are in
industrial or light industrial areas.
Best regards,
Kim Boll Jensen
Bolls Raadgivning
Consultancy in EMC & Safety approvals world wide
rehel...@mmm.com skriver:
> If you have ITE
Hi
Can som one help me. One of our costumers wants a Surge test according to
"TS0098/96 Part 1 issue Feb. 98". Where do I find this standard and what is
the data of the surge test, is it like an ITU or FCC surge puls ?
Best regards,
Kim Boll Jensen
Approval manager
Eicon Networ
t for that.
Can some one give me names of possible test houses so we don't have to
retest it all.
Best regards,
Kim Boll Jensen
Approval manager
Eicon Networks
Denmark
---
This message is from the IEEE EMC Society Product Safety
Technical Committe
Hi,
Some years ago I got one from a firm making ballbearing (SKF) they sell the
ball's seperately.
Best regards,
Kim Boll Jensen
i-data international
Denmark
jim_bac...@mail.monarch.com (Jim Bacher) on 21-03-2000 13:29:50
Please respond to jim_bac...@mail.monarch.com (Jim Bacher
Dear all,
Can someone help me ! I need the MIL-STD-461B and C version (I have D version)
can I download these versions form the internet ?
Best regards,
Kim Boll Jensen
-
This message is coming from the emc-pstc discussion list.
To cancel your subscription, send mail to majord
-- Forwarded by Kim Boll Jensen/INT on 2000-01-18 08:28
---
Helge Knudsen on 2000-01-17 19:11:53
Please respond to "hknud...@image.dk"
To: Kim Boll Jensen/INT
cc:
Subject: RE: EN 61000-4-2
I will just forward this answer since t
umber is 50 at each points (but
without any reference to any standard).
Do anynoe know what the right number is and where I can find it
Best regards,
Mr. Kim Boll Jensen
i-data international
Denmark
-
This message is coming from the emc-pstc discussion list.
To cancel your subscription,
In Denmark the Factories Inspectorate have some local guids for employees. So I
think you have to contact the Factories Inspectorate in your country.
Best regards,
Kim Boll Jensen
i-data, Denmark
roger.vi...@wwgsolutions.com on 99-12-22 15:12:34
Please respond to roger.vi
e and will not accept a CD only.
Can anyone help me in finding requirements for a paper version. (EN 60950 1.7.2
Safety Instructions; say "If it is necessary...")
Best regards,
Kim Boll Jensen
i-data international
Denmark
-
This message is coming from the emc-pstc discussion
ll or know.
Best regards,
Kim Boll Jensen
i-data international, Denmark
"Sandy Mazzola" on 99-12-01 23:25:32
Please respond to "Sandy Mazzola"
To: emc-p...@majordomo.ieee.org
cc:(bcc: Kim Boll Jensen/INT)
Subject: Question about EN55024
To All,
mance criterion A or B ?
IEC 1000-4-4 Burst; on DC power supply, what is the performance criterion A or B
?
Best regards,
Kim Boll Jensen
-
This message is coming from the emc-pstc discussion list.
To cancel your subscription, send mail to majord...@ieee.org
with the single line: "u
Yes Denmark is a full member of the EU and therefor CE marking is required.
Denamrk have national deviation to EN 60 950 as many of the other EU countries
have. You can find them in the CB bullitin.
Best regards,
Mr. Kim Boll Jensen
i-data, Denmark
b...@anritsu.com (Bailin Ma) on 99-09-28
Dear Mohajer and all
If you are using type K thermocouplers you will have to turn off power to the
component before measuring the temp. Since they are sensitive to magnetic
fields.
Best regards,
Mr. Kim Boll Jensen
i-data, Denmark
Kamran Mohajer on 99-08-24 23:50:26
Please respond to
Dear All,
Can anyone recommend a suplier of an antenna preamplifier for a TEM celle
connected to a spectrum analyzer, for measuring from 30MHz to 1GHz. I need
arround 10 - 20 dB gain
Best regards,
Mr. Kim Boll Jensen
i-data, Denmark
-
This message is coming from the emc-pstc
n the
invoice/customs papers or do we have to use form 740 ?
If I need to use form 740 does anyone help me with a EDB version (the one which
I can downloade from FCC is scanned and can not be edited).
Best regards,
Mr. Kim Boll Jensen
i-data, Denmark
-
This message is coming from th
x27;s
just nice to have to help users.
Best regards,
Mr. Kim Boll Jensen
i-data, Denmark
-
This message is coming from the emc-pstc discussion list.
To cancel your subscription, send mail to majord...@ieee.org
with the single line: "unsubscribe emc-pstc" (without the
quot
Hi groupe
I'm tryimg to find an inductor for load test of a LAN circuit (10/100Base
UTP). Do anyone know a manufacturer of 1% 220uH and 180uH inductors with
the following specifications:
Rparallel > 2Kohm, Rserial < 0.5 ohm and Cparallel = 12pF +-20%
Best regards,
Mr. Kim Bol Jensen
i-data, D
institute).
And furter UL is not a "must" for AC powered devices there are some
alternatives for the US market.
Best regards :-)
Mr. Kim Boll Jensen
i-data, Denmark
-
This message is coming from the emc-pstc discussion list.
To cancel your subscription, send mail to majord.
countries ?
-which authoryties requires this informations other than EU directives (and
FCC part 68)
Best regards,
Mr. Kim Boll Jensen
i-data, Denmark
-
This message is coming from the emc-pstc discussion list.
To cancel your subscription, send mail to majord...@ieee.org
the equipment is OK:
This equipment complies with the requirements in Part 15 of FCC Rules.
See manual
Where have UL got this text from and is it OK to use this short version ?
Best regards,
Mr. Kim Boll Jensen
i-data, Denmark
-
This message is coming from the emc-pstc
Boll Jensen
i-data, Denmark
-
This message is coming from the emc-pstc discussion list.
To cancel your subscription, send mail to majord...@ieee.org
with the single line: "unsubscribe emc-pstc" (without the
quotes). For help, send mail to ed.pr...@cubic.com,
j...@gwmail.monar
Dear group,
Can anyone help me with the layout of the EU telecom marking. Where can I
down load the X mark layout .
Best regards,
Kim Boll Jensen
i-data, Denmark
-
This message is coming from the emc-pstc discussion list.
To cancel your subscription, send mail to majord...@ieee.org
Can somebody tell me what I need to do for protecting an ISDN-S and -U
interface concerning transients on the line (both burst and surge).
Best regards,
Mr. Kim Boll Jensen
I-data, Denmark
-
This message is coming from the emc-pstc discussion list.
To cancel your subscription, send
Can somebody tell me what I need to do for protecting an ISDN-S and -U
interface concerning transients on the line (both burst and surge).
Best regards,
Mr. Kim Boll Jensen
I-data, Denmark
-
This message is coming from the emc-pstc discussion list.
To cancel your subscription, send