Re: C-Tick mark

1997-01-15 Thread WOODS, RICHARD
Bill, we just received our official copy of the file that describes the C-tick mark. It is strickly a graphics file with no dimensional infomation whatsoever. Very disapointing! Richard Woods Sensormatic Electronics -- From: b...@lyons.demon.co.uk To: ch...@jna.com.au; glfra

Re: C-Tick mark

1997-01-15 Thread Dave Perlmutter/US/3Com
Cortland, I checked the CKC site as you recommended below. The "guidance" on the C-tick mark to which you refer is out-of-date. CKC's document is based on the July 1995 edition of the EMC Frameworks. The SMA made major amendments to the Framework in March 1996. One of

Re: C-Tick mark

1997-01-15 Thread Tony Fredriksson
3548 (the equivalent of EN 55022). Regards, tony_fredriks...@netpower.com -- From: Dave_Perlmutter/US/3Com%3COM To: Cortland.Richmond-CC Cc: emc-pstc; George Alspaugh Subject: Re: C-Tick mark List-Post: emc-pstc@listserv.ieee.org Date: Wednesday, January 15, 1997 12:00AM Cortland, I ch

Re: C-Tick mark

1997-01-15 Thread Chris Healy
Bill, I feel a bit like a PR rep. for Standards Australia and the SMA today. Both the C-tick and the RCM are available as software and hard copy format from Standards Australia. The catch is that you need to supply a copy of an authorization to use the mark from the relevant regulator. Foreign

Re[2]: C-Tick mark

1997-01-15 Thread Cortland . Richmond-CC
Thanks for the word, Dave. I will know not to rely on the printed material they supply, then. Sic transit tyrannosaurus, right? Cortland __ Reply Separator _ Subject: Re: C-Tick mark Author: Dave

C-Tick Mark and GTEM

1998-11-17 Thread rogerhsu
What are the EMC requirements for applying C-Tick Marking for Power Supply Unit for information technology equipment? Is it only Conducted and Radiated emissions? Has anybody ever used the GTEM emissions results as the official results to apply any of the EMC marks? (l

C-Tick Mark, For NZ Too?

1998-09-18 Thread eric . lifsey
Forgive my ignorance, but is the C-Tick Mark (Australia's EMC Framework) required for New Zealand too? Based on what I have available, the Framework is an Australian regulation, though the standards (prefaced AS/NZS) happen to be aligned (harmonized?) on a regional basis between th

RE: C-Tick Mark and GTEM

1998-11-17 Thread WOODS, RICHARD
: C-Tick Mark and GTEM What are the EMC requirements for applying C-Tick Marking for Power Supply Unit for information technology equipment? Is it only Conducted and Radiated emissions? Has anybody ever used the GTEM emissions results as the

Re: C-Tick Mark, For NZ Too?

1998-09-20 Thread Barry Esmore
Eric, NZ has EMC regulations, but It is not compulsory to mark the equipment. On 1 Jan 1999 they plan to harmonise with the Australian C-tick regs. This means that you will be able to use a single compliance folder and C-tick mark for both countries. Regards Barry Esmore > > Forg

Re: C-Tick Mark, For NZ Too?

1998-09-21 Thread Mark Briggs
At 05:12 PM 9/18/98 -0500, you wrote: >Forgive my ignorance, but is the C-Tick Mark (Australia's EMC Framework) required for >New Zealand too? > >Based on what I have available, the Framework is an Australian regulation, though the >standards (prefaced AS/NZS) happen to be alig