In message
041420061600.25253.443FC718000D513562A52206824693CECE020A900A02@comc
ast.net, dated Fri, 14 Apr 2006, neve...@comcast.net writes
A relatively simple resistive network can be designed for measuring
common-mode voltage on Ethernet and many other high-speed interfaces
that utilize
A relatively simple resistive network can be designed for measuring
common-mode voltage on Ethernet and many other high-speed interfaces that
utilize differential-pair lines, which - with minor modifications - would be
perfectly suitable for this application. I have used it for about 10 years,
had
In message
of83d77521.a76d1666-on8525714f.004fc2d9-8525714f.00506...@pb.com,
dated Thu, 13 Apr 2006, jim.hulb...@pb.com writes
We have an ethernet port to which is connected a CAT5 cable. When this
cable is routed through an ISN per EN 55022 for conducted emissions
measurements, the port is
From: jim.hulb...@pb.com [ mailto:jim.hulb...@pb.com]
Sent: Thursday, April 13, 2006 7:38 AM
To: emc-p...@ieee.org
Subject: Conducted Emissions on Ethernet
We have an ethernet port to which
Jim,
I am not a test-house, so I don't have experience with various ISNs. However,
I have done a considerable amount of work in common-mode voltage and current
measurements, as well as investigating imbalance (i.e. mode conversion) in
differential-signaling, especially in the hi-speed
We have an ethernet port to which is connected a CAT5 cable. When this cable
is routed through an ISN per EN 55022 for conducted emissions measurements,
the port is unable to function. What experience have people had with ISNs in
this application, or what experience do people have with the