19:59 -0500
> To: "EMC-PST (E-mail)"
> Subject: HIRF Testing
>
>
> Group,
>
> I am looking for a HIRF Test facility to do a test to N8110.71 Table 2
> levels which go as high as 3000V/m. Does anyone know of a lab with the
> capability?
>
> I know TUV
I read in !emc-pstc that Donnelly, Thomas wrote
(in <594c7b223d72d511a4810008c786c1060251f...@srvr01.act-sys.net>) about
'HIRF Testing' on Thu, 4 Mar 2004:
>I am looking for a HIRF Test facility to do a test to N8110.71 Table 2
>levels which go as high as 3000V/m. Does any
>-Original Message-
>From: Donnelly, Thomas [mailto:tdonne...@act-sys.com]
>Sent: Thursday, March 04, 2004 5:20 AM
>To: EMC-PST (E-mail)
>Subject: HIRF Testing
>
>
>
>Group,
>
>I am looking for a HIRF Test facility to do a test to N8110.71 Table 2
>leve
Try
http://www.retlif.com/electro.htm
They may have what you need.
Mark Schmidt
From: Donnelly, Thomas [mailto:tdonne...@act-sys.com]
Sent: Thursday, March 04, 2004 8:20 AM
To: EMC-PST (E-mail)
Subject: HIRF Testing
Group,
I am looking for a HIRF Test facility to do a test to N8110.71
Group,
I am looking for a HIRF Test facility to do a test to N8110.71 Table 2
levels which go as high as 3000V/m. Does anyone know of a lab with the
capability?
I know TUV America has this capability but they don't seem to want to
respond to my requests for quote. I am very displeased with their
HI Susan,
we may be of help, what specifically do you want to know?
Derek Walton
Please note that the following are personal comments and not those of my
employer.
I am looking for information both on the environments (assume aircraft)
that justify the following levels and the methods for testing. I have been
asked to find EMI labs that can test to the following:
900M
7 matches
Mail list logo