Re: panic: integer divide fault with vinum

1999-04-10 Thread Michael Reifenberger
On Sat, 10 Apr 1999, Greg Lehey wrote: ... In fact, it's not necessary. It happens any time you detach the last subdisk from a striped or RAID-5 plex. Ups... Correct. What happened to the stack traces? Don't bother, though, I've reproduced it here. Expect a fix in a couple of hours. Sorry,

panic: integer divide fault with vinum

1999-04-09 Thread Michael Reifenberger
Hi, next try. Please forgive if gets too stupid :-) # cat x drive d1 device /dev/da1d drive d2 device /dev/da2d volume raid plex org stripe 256k sd length 50m drive d1 sd length 50m drive d2 (please note again the misspelling of striped) # vinum create x 1: drive d1 device /dev/da1d ** 1

Re: panic: integer divide fault with vinum

1999-04-09 Thread Greg Lehey
On Friday, 9 April 1999 at 15:01:51 +0200, Michael Reifenberger wrote: Hi, next try. Please forgive if gets too stupid :-) # cat x drive d1 device /dev/da1d drive d2 device /dev/da2d volume raid plex org stripe 256k sd length 50m drive d1 sd length 50m drive d2 (please note again

Re: panic: integer divide fault with vinum

1999-04-09 Thread Michael Reifenberger
On Sat, 10 Apr 1999, Greg Lehey wrote: ... You need to configure it. Use disklabel -e. No, they where configured. I have one ' d: 17848151 63 vinum' slice per drive. The only fault where the misspelling of 'stripe' versus 'striped' in the configfile! ... Not much of anything,

Re: panic: integer divide fault with vinum

1999-04-09 Thread Greg Lehey
[Format recovered--see http://www.lemis.com/email/email-format.html] On Saturday, 10 April 1999 at 3:37:47 +0200, Michael Reifenberger wrote: On Sat, 10 Apr 1999, Greg Lehey wrote: ... You need to configure it. Use disklabel -e. No, they where configured. I have one ' d: 17848151 63

Re: panic: integer divide fault with vinum

1999-04-09 Thread Michael Reifenberger
On Sat, 10 Apr 1999, Greg Lehey wrote: ... It looks like you have them now, but you didn't then. Strange, I'm shure I haven't touched them. The only fault where the misspelling of 'stripe' versus 'striped' in the configfile! That's not what your error messages are trying to tell you.

Re: panic: integer divide fault with vinum

1999-04-09 Thread Greg Lehey
On Saturday, 10 April 1999 at 4:05:10 +0200, Michael Reifenberger wrote: On Sat, 10 Apr 1999, Greg Lehey wrote: The panic occurs only, if I first use the incorrect config file with 'stripe', then the corrected one with 'striped' and then detaching the plex and the subdisks. This point is