I am also the same as Joelle Brian, It never been questioned by CAP
inspectors but since it's in the common checklist we have to follow that’s
why we have a policy with simple procedure and record, the procedure almost
the same as Brian procedure but some time we use the digital PH meter.
Best
I would recommend using Kristensen's sodium formate/formic acid mixture.
This is more gentle than formic acid alone and almost as rapid.
Barry
On Tue, Aug 5, 2014 at 12:01 PM, DiCarlo, Margaret
mdica...@kaleidahealth.org wrote:
I use 10% formic acid for large human bones but I don't think
Ditto with Brian Cooper.
Michael Ann Jones, HT (ASCP)
Histology Manager
Metropath
7444 W. Alaska Dr. #250
Lakewood, CO 80226
303.634.2511
mjo...@metropath.com
On 8/5/14, 1:07 PM, Cooper, Brian bcoo...@chla.usc.edu wrote:
I've never been asked by a CAP auditor either, but our internal
Hello All,
I have a company who needs: a source of basic services for
sectioning of GMA blocks containing biomaterial devices and subsequent
HE staining. The devices are cut for embedding to about 8mm in
length, and contain adhesives, thermoplastic membranes, various
scaffolds, and cells. Our
Does anyone know of a comparable clone to the Ventana p16 clone E6H4? I would
prefer it to be undiluted (concentrate) so that we can titrate out the antibody
ourselves. We need it to have publications that would back this up and/or
stained slide pictures I can show our pathologist.
Thanks
We pour our waste xylene/alcohol into a drum and the formalin waste in a
seperate drum for a waste service company to remove. Problem is space to
house 55 gal drums and we have more xylene/alc waste than formalin. Does
anyone neutralize formalin and dispose of it down the drain? If so can
Hi Bret
We are using 10% Formic Acid as well and checking the decalcifying end-point by
using the faxitron x-ray system. I work with bone cancer for 99% of the time
and Formic Acid is safer than any other one.
Thomas
-Original Message-
From: histonet-boun...@lists.utsouthwestern.edu
Maryann:
In spite of any seller's or user's opinion, I tried ALL available formalin
neutralizers available in the market up to 2002 and was able to detect, after
the so called neutralization, significant amounts of free formalin still
present.
Because of these results I decided to keep sending
Dear all,
For those of you using the SlideMate, can you give me a list of compatible
slides for these units?
Thanks!
Teri Johnson
Manager, Histology
Genomics Institute for
Novartis Research
Foundation
San Diego, CA
858-332-4752
___
Histonet mailing
Hello All,
Thank you to all who responded to my query about the RI company. I
have forwarded all your emails directly to the company. Who ever has
the pleasure to service the company, you have my gratitude.
Best
Hans B Snyder
Histologistics
60 Prescott Street
Worcester, MA 01605
508-308-7800
Teri,
We have found that these slides work the best:
Leica
Part # 3800090
SLIDE WHITE Xtra Thermal (Color should not matter, we tried several different
colors with good results)
Walter Benton HT(ASCP)QIHC
Histology Supervisor
Chesapeake Urology Associates
806 Landmark Drive, Suite 127
Glen
I use the EPIC slides from CWS, Have always used them on this printer but have
tried many other brands - these are the BEST.
Andrea Grantham, HT (ASCP)
Senior Research Specialist
University of Arizona
Cellular and Molecular Medicine
Histology Service Laboratory
P.O.Box 245044
Tucson, AZ 85724
It is an exclusive Ventana product - sold through MTM Laboratories I believe it
is.
Joyce Weems
Pathology Manager
678-843-7376 Phone
678-843-7831 Fax
joyce.we...@emoryhealthcare.org
www.saintjosephsatlanta.org
5665 Peachtree Dunwoody Road
Atlanta, GA 30342
This e-mail, including any
Before Ventana had p16, it was only available from MTM labs, if I recall
correctly the name. I am not sure if Ventana is the exclusive vendor now or
not. Good luck.
On Aug 6, 2014, at 3:13 PM, Burnett, Brandy bburn...@capecodhealth.org
wrote:
I am looking for one as well, I wasn't sure if
They bought the company!
Joyce Weems
Pathology Manager
678-843-7376 Phone
678-843-7831 Fax
joyce.we...@emoryhealthcare.org
www.saintjosephsatlanta.org
5665 Peachtree Dunwoody Road
Atlanta, GA 30342
This e-mail, including any attachments is the property of Saint Joseph's
Hospital and is
For many years now I have used this protocol in Bone
Marrow samples.
The cortical of the bone is still a problem, but it
can be solved with longer decal time.
If you need to preserve morphology and antigenicity
for Immunohistochemistry this is the best choice.
Three Days Bouin’s Fixative (
Dear all,
I was wondering if there's any one out there using the AP Module of the Cerner
Millennium LIS with their Advanced Barcode and Tracking (ABT) solution?
And also, if there's anyone out there using the AP Module of the Cerner
Millennium LIS interfaced with Leica's Cerebro Specimen
17 matches
Mail list logo