Could it be due to incomplete deparaffinization?
Willem
Van: Vickroy, James via Histonet [histonet@lists.utsouthwestern.edu]
Verzonden: dinsdag 16 februari 2016 18:10
Aan: histonet@lists.utsouthwestern.edu
Onderwerp: [Histonet] Nuclear Bubbling
Struggli
Hello All,
Does anyone have experience staining the keratohyalin granules in skin with
different types of hematoxylins? I am currently looking at keratohyalin
granules and staining with Harris hematoxylin and there seems to be little
staining and not as prominent as I would have expected. Won
Greetings all,
Does anyone have a new employee check-off worksheet that they would be willing
to share for histotech's?Thanks in advance!
Elaine Hoffman
___
Histonet mailing list
Histonet@lists.utsouthwestern.edu
http://lists.utsouthwestern.edu/mailman/l
Hello,
I manage a small Pathology lab where we generate approx. 80-140 blocks for
Histo and 5-6 Cytology fluids a day. I have 2 Histotechs that swap doing
grossing monthly. I have 1 full time and 1 part time Cytotech and a Cyto
assistant. I am curious if there are any smaller labs out there that
NSH has an archived webinar: Nuclear Bubbling: It's About Time" created by
Peggy Wenk. The webinar talks about several causes of nuclear bubbling,
changes that can be made to reduce this problem, and, for really bad cases,
Peggy talks about how to dry the slide differently, reprocess tissue or
Jim,
Are you drying the slides in an oven before the heat stage on the Prisma? If
you use an oven, what is the temperature setting and for how long are slides
kept in? Carson and Hladik recommends 60 degrees for less than 1 hour.
You mentioned, recycled formalin, what is the pH of the formalin?
Hello Histopeeps!
Happy Hump Day! We are halfway to the weekend!
We GOT This!!
Since it's mid-week and my phone is ringing off the hook with new
opportunities I wanted to do a quick post to tell you about the positions
that I am working on and am MOST excited about.
Why am I excited about these po
Does anyone have a policy that they are willing to share regarding tech errors,
error prevention, etc?
How do you document, retrain, write up, and terminate employees for errors?
What is considered severe problems for termination, etc.
I know it is up to the manager, I want to know what othe
Good Day Everyone,
I am looking to obtain used Thermo Sequenza Immunostaining Racks (about 10 or
so). Does anyone have any that they would be willing to part with?
Please feel free to contact me directly.
Thanks in advance!
Carlos
Carlos Genty
Critical X Solutions, LLC
cge...@criticalxso