Howard Rifkind wrote:
Ulrich,
Can sFTP and FTP reside within the same z/OS partition and be used at the same time?
For instance, one person is FPT'ing a secure document using sFTP and another is using just plain old FTP for something else
You could use three different kinds of file
Anyone need some antique peripherals? We don't have space to keep them.
Details and photos at http://www.protechpts.com/misc/peripherals.html
Regards,
Bob Stark [ProTech - When you're serious about Systems Management]
Consulting, Software, and Training for OS/390, UNIX and Internet
A while ago we established RACF command protection for MQS commands. We
had/sometimes have the following phenomenon:
- A sysplex of several systems
- MQS is executing on system A
- LOGON(REQUIRED) for all MCS consoles
- The userids are authorized to the appropriate MQS commands
A command like DIS
Hi
Try to IPl a test z/OS 1.4 in a 1Gbyte real storage LPAR and got
IEA303W ABEND BD4 REASON DURING INITIALIZATION UNDER RIM IEAVNPA1
and a wait state.
--
For IBM-MAIN subscribe / signoff / archive access
I don't think it's prudent for younger people to focus on I.T. as a
life
long career.
You may be right. Of course, it's also a self-fulfilling prophecy. If
more Americans reject computer science American corporations will have
no choice but to go overseas for talent.
Bob Shannon
Hi,
If you check e-week you'll see that BOA and other banks were recently the
target of a theft ring. About 300,000 persons had their banking information
stolen because of computer systems being compromised.
I don't think CEO pay amount is the problem so much as their remuneration
being tied to
You have three variables to work with in software projects; 1. Fast, 2.
Cheap and 3. Good.
You only get to pick two of the variables because the third will be
sacrificed.
Paul Hanrahan
-Original Message-
From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On Behalf
Of jamesfs
Bob,
I'd call it a degenerative spiral at this point not a self fulfilling
prophecy. 50% of those who went through comp sci programs in California in
the last ten years are no longer in the business. The comp sci folks who
have given up on their desired career don't show up in government stats as
Hi,
Maybe this is a dum question, but here it goes:
I'm looking at ICETOOL for displaying SMF71 records and for the majority of
the fields it works OK. But...
Is there a way to process the floating fields (like the high-medium-low
impact central storage frames...) in ICETOOL or it is
Hello,
I'm going to add an initiator in a given class.
Actually, I have 60 defined initiators and PARTNUM in the INITDEF macro
is set to 60 too.
Must PARTNUM exactly match the number of defined initiators?
Can't it be larger?
And what could I monitor when I add new initiators?
Thanks a lot in
Hi there,
I was adding a new CHP to a device and reused an old CHP. I can't get the
new CHP working and when I list the CHP (d m=chp(B8)) I get:
CHPID B8: TYPE=04, DESC=ESCON SWITCHED OR POINT TO POINT, ONLINE
When looking at the other CHPs for the same device I get:
CHPID B0: TYPE=03,
In a message dated 5/29/2005 8:45:55 P.M. Central Daylight Time,
[EMAIL PROTECTED] writes:
Probably the biggest customer of this type is the US Government...
Unfortunately, it's difficult, say for a particular Army base running a
personnel system and maybe a few other local applications,
Ottar Moller wrote:
Hi there,
I was adding a new CHP to a device and reused an old CHP. I can't get the
new CHP working and when I list the CHP (d m=chp(B8)) I get:
CHPID B8: TYPE=04, DESC=ESCON SWITCHED OR POINT TO POINT, ONLINE
When looking at the other CHPs for the same device I get:
:)
-- From: Volker Bandke
Ex Cathedra?
-- From: Paul Gilmartin
Mr. Gilmore has stated,
http://bama.ua.edu/cgi-bin/wa?A2=ind0505L=ibm-mainD=1O=DP=199529
that he has verified that such a distinction is operational. He has not
chosen to share the details of the verification with the
Hello Ottar,
I think you maybe had got PATH errors when you configured CHPID B8 online.
Please supply messages resulting from the CF CHP(B8),ONLINE command,
including any path related messages.
Also please provide complete D M=CHP(B0,B8) report. The additional data
might provide the missing