Reusing old 3590 Tapes

2009-06-08 Thread Richman, Saul
Hello, Anyone with experience of re-using "old" tapes? Can we reuse physical 3590 Cartridges (High-Performance Model-B11) that have been stored for ca. 6 Years in Computer Room condition? Our (non-IBM) Engineer claims: "Old tapes that have been left in storage can damage the Drive heads in our

Re: Reusing old 3590 Tapes

2009-06-08 Thread R.S.
Richman, Saul pisze: Hello, Anyone with experience of re-using "old" tapes? Can we reuse physical 3590 Cartridges (High-Performance Model-B11) that have been stored for ca. 6 Years in Computer Room condition? Our (non-IBM) Engineer claims: "Old tapes that have been left in storage can damage

Re: IEFBR14

2009-06-08 Thread R.S.
Chase, John pisze: [...] Similar functionality might be handy in ADRDSSU wrt migrated datasets to be deleted: //STEP1 EXEC PGM=ADRDSSU[,parms] //OUTDD DD DUMMY // //SYSIN DD * DUMP DS(. . .) - PURGE - . . . I.e., if function = logical DUMP with PURGE, *AND* the output is DU

Any products to protect MVS software from cracking and reverse engineering?

2009-06-08 Thread shai hess
Any products to protect MVS software from cracking and reverse engineering? In these days I study about reverse engineering and cracking in PC and protection of your product from bad actions in your code. This area is very inters thing to learn. Tools like Ollydbg, IDA pro make the code in PC tot

Re: Any products to protect MVS software from cracking and reverse engineering?

2009-06-08 Thread Binyamin Dissen
On Mon, 8 Jun 2009 02:31:21 -0700 shai hess wrote: :>Any products to protect MVS software from cracking and reverse engineering? Not really. If one wanted to, one could stop the machine and do a standalone dump. That provides all storage in a way where it can be examined at leisure. You can tr

Re: IEFBR14 in z/OS R.11

2009-06-08 Thread Peter Relson
The complicating factor, in terms of "prior behavior", involves in some way a multi-step job and/or the REFDD JCL statement and, as mentioned, someone superseding the system's IEFBR14.. I believe the intent is to enable this support via a parmlib option. Peter Relson z/OS Core Technology Design

Re: SHOWzOS SHORT_PUTLINE

2009-06-08 Thread Klein, Kenneth
READY SHOWZOS PUTLINE GSF Utilities - SHOWzOS R7132009-06-05 11.18 SHOWMVS is running authorized >Operating System: z/OS 01.09.00 FMID: HBB7740CVTOSLVL: FF FF FF BF EF 70 00 00 DFSMS 1.9.0 Feature : FF 6F 77 7F A0 30 I don't k

Re: IEFBR14 in z/OS R.11

2009-06-08 Thread Chase, John
> -Original Message- > From: IBM Mainframe Discussion List On Behalf Of Martin Packer > > IDCAMS would be another one. (That was my reaction when I first heard of > this.) But note both of these are MUCH harder because that would require > reading of SYSIN - perhaps from data sets. They (

Re: SHOWzOS SHORT_PUTLINE

2009-06-08 Thread Roland Schiradin
Hi Ken, I'm the "owner" Please download version 7.18 from www.cbttape.org (http://www.cbttape.org/updates.htm) FILE#492 Roland > >READY > >SHOWZOS PUTLINE > >GSF Utilities - SHOWzOS R7132009-06-05 >11.18 >SHOWMVS is running authorized > >>Operating System: > >

Re: SHOWzOS SHORT_PUTLINE

2009-06-08 Thread Klein, Kenneth
Thanks, Roland. And it even runs as a batch job!! So cool. But under tso it still gets a soc4 and a soc7 in ispfinit. Do you want to see any dump information? Ken Klein Sr. Systems Programmer kenneth.kl...@kyfb.com 502-495-5000 x7011 -Original Message- From: IBM Mainframe Discussion

Re: The Great MVS Decommission Plan

2009-06-08 Thread Bill Fairchild
In the HTML version I didn't see any timeline for removing MVS from the computer science curriculum. Or have they already done that? Looks as if Bob Rannie and Mike Stack took their NIU retirement just in time. Bill Fairchild Software Developer Rocket Software Tel: +1.617.614.4503 * Mobile

Fw: IEFBR14 (was: EXEC Above the Bar)

2009-06-08 Thread Steven B Jones
It's true that IEFBR14 will now get special treatment for the purposes of batch allocation. I don't know if I would call that a "reserved word." We thought about the steplib case. If a programmer writes his own IEFBR14, he can expect the system to behave as if it were the "real" IEFBR14 shipp

Re: IEFBR14 (was: EXEC Above the Bar)

2009-06-08 Thread O'Brien, David W. (NIH/CIT) [C]
I for one look forward to jobs which now take hours taking just a few minutes once we get to 1.11. Dave O'Brien NIH Contractor From: IBM Mainframe Discussion List [ibm-m...@bama.ua.edu] On Behalf Of Steven B Jones [...@us.ibm.com] Sent: Monday, June 08, 2

Re: Help on IEBEDIT Utility

2009-06-08 Thread Subcribe Ibm-Main Anonymous
Here's a link to the manual: http://publibfp.boulder.ibm.com/cgi-bin/bookmgr/BOOKS/dgt1u104/5.0? SHELF=&DT=19990113105507 If your INCLUDE statement is the first statement before any steps of the job it won't pick it up. In that case, I added the following before the INCLUDE, and it picked up t

Re: Help on IEBEDIT Utility

2009-06-08 Thread Tony B.
Not true. I have many working examples of "include" statements that precede steps. The functionality depends on what the "include" contains. -Original Message- From: IBM Mainframe Discussion List [mailto:ibm-m...@bama.ua.edu] On Behalf Of Subcribe Ibm-Main Anonymous Sent: Monday, June

Re: IEFBR14 (was: EXEC Above the Bar)

2009-06-08 Thread Paul Gilmartin
On Mon, 8 Jun 2009 10:24:19 -0400, O'Brien, David W. (NIH/CIT) [C] wrote: >I for one look forward to jobs which now take hours taking just a few minutes >once we get to 1.11. > Hours? I'm surprised that while you were waiting hours for one of those jobs to complete you didn't take the opportunit

Re: IEFBR14 (was: EXEC Above the Bar)

2009-06-08 Thread O'Brien, David W. (NIH/CIT) [C]
Gil, No, those are user jobs. And no amount of prodding on my part will get an apps owner to change anything that returns rc=0. Dave O'Brien NIH Contractor From: IBM Mainframe Discussion List [ibm-m...@bama.ua.edu] On Behalf Of Paul Gilmartin [paulgboul.

Re: IEFBR14 (was: EXEC Above the Bar)

2009-06-08 Thread Gilbert Saint-Flour
On Monday 08 June 2009 16:20, Steven B Jones wrote: > It's true that IEFBR14 will now get special treatment for the purposes of > batch allocation.  I don't know if I would call that a "reserved word." > > We thought about the steplib case.  If a programmer writes his own > IEFBR14, he can expect

SDSF anomaly - z/OS migration from v1.7 to v1.9

2009-06-08 Thread Mike Myers
Hi: We are migrating to z/OS v1.9 and have gone from SDSF at HQX7720 to SDSF at HQX7740. Something has happened to the list of jobs that are viewable in the Held and Output queues under SDSF. Some jobs will not appear in either list (on z/OS v1.9 - SDSF at HQX7740) but will appear in the li

Re: IEFBR14 (was: EXEC Above the Bar)

2009-06-08 Thread Paul Gilmartin
On Mon, 8 Jun 2009 17:52:54 +0200, Gilbert Saint-Flour wrote: > >That reminds me of something I saw in the early 1980s, i.e. a home-written >utility called IEFBR14 which was designed to run in batch jobs to clean up >certain files, but I'm not sure what it really was doing. I also remember a I co

What is System Completion Code FD6?

2009-06-08 Thread Johnson Jr., Donald E
I have tried Google and Quick-Ref, and come up empty here. How can I track down what this means and how to fix it? Thanks! Don Johnson CA Sr. Support Engineer Email donald.john...@ca.com   This e-mail and any files transmitted with it are for the sole use of the intended recipient(s) and cont

Re: What is System Completion Code FD6?

2009-06-08 Thread Mark Jacobs
Johnson Jr., Donald E wrote: > I have tried Google and Quick-Ref, and come up empty here. How can I track > down what this means and how to fix it? > > Thanks! > > Don Johnson > CA > Sr. Support Engineer > Email donald.john...@ca.com > > This e-mail and any files transmitted with it are for the

Re: What is System Completion Code FD6?

2009-06-08 Thread Ed Finnell
In a message dated 6/8/2009 11:11:17 A.M. Central Daylight Time, donald.johnso...@ca.com writes: I have tried Google and Quick-Ref, and come up empty here. How can I track down what this means and how to fix it? >> >From Systems Codes: Explanation: The system detected an error while pro

Re: What is System Completion Code FD6?

2009-06-08 Thread Mark Zelden
On Mon, 8 Jun 2009 12:10:10 -0400, Johnson Jr., Donald E wrote: >I have tried Google and Quick-Ref, and come up empty here. How can I track down what this means and how to fix it? > >Thanks! > >Don Johnson >CA >Sr. Support Engineer >Email donald.john...@ca.com >  It is documented in the MVS Sys

Re: What is System Completion Code FD6?

2009-06-08 Thread Binyamin Dissen
On Mon, 8 Jun 2009 12:10:10 -0400 "Johnson Jr., Donald E" wrote: :>I have tried Google and Quick-Ref, and come up empty here. How can I track down what this means and how to fix it? Most Fxx abends mean that you issued an undefined SVC, in your case D6 = 221 which, if I recall correctly, is the

Re: What is System Completion Code FD6?

2009-06-08 Thread Steven Conway
In QuickRef, do Categories, then System Abend Codes. Select any of the system abend codes Fxx: Fnn Explanation: The system detected an error while processing a Supervisor Call (SVC) instruction. The last 2 digits of this completion code, nn, are the operand of the SVC instruction in hexadecima

Re: What is System Completion Code FD6?

2009-06-08 Thread Field, Alan C.
Look in the MVS System Codes document. Fnn are issued for errors detected in SVC nn (nn = X'D6' = 214) So you have an error from SVC 214. SVCs > 199 are typically USER SVCS. Figure out who provided this SVC and contact them for support. Alan -Original Message- From: IBM Mainframe Dis

Re: IEFBR14 (was: EXEC Above the Bar)

2009-06-08 Thread Pommier, Rex R.
Gil, I know that you're not in charge of the systems, but have you looked at the DFSMShsm patch that converts interactive recalls to no wait? PATCH .MCVT.+52 BITS(..1.) /* ALTER TAPE RECALLS TO NOT WAIT */ According to the diagnosis manual, When set to 1, intercept driven tape    reca

Re: What is System Completion Code FD6?

2009-06-08 Thread Wayne Driscoll
Look in MVS System Codes under Fnn. It usually indicates an invalid SVC instruction (X'D6' = 214 dec). Probably there is no SVC table entry that corresponds to USER SVC 214. === Wayne Driscoll OMEGAMON DB2 L3 Support/Development wdrisco(AT)us.ibm.com

*RESOLVED* What is System Completion Code FD6

2009-06-08 Thread Johnson Jr., Donald E
Thanks everyone for your help. This is truly a great group for responding so quickly! I also know now where to find this sort of error, as there were no other messages to point me to the SVC error. Thanks once again! Don Johnson CA Sr. Support Engineer Email donald.john...@ca.com This e-mail

Re: What is System Completion Code FD6?

2009-06-08 Thread Binyamin Dissen
On Mon, 8 Jun 2009 12:10:10 -0400 "Johnson Jr., Donald E" wrote: :>I have tried Google and Quick-Ref, and come up empty here. How can I track down what this means and how to fix it? Most Fxx abends mean that you issued an undefined SVC, in your case D6 = 214. Figure out what the program expects

Re: What is System Completion Code FD6?

2009-06-08 Thread Mark Zelden
On Mon, 8 Jun 2009 11:22:41 -0500, Mark Zelden wrote: >On Mon, 8 Jun 2009 12:10:10 -0400, Johnson Jr., Donald E > wrote: > >>I have tried Google and Quick-Ref, and come up empty here. How can I track >down what this means and how to fix it? >> >>Thanks! >> >>Don Johnson >>CA >>Sr. Support Enginee

Re: What is System Completion Code FD6?

2009-06-08 Thread Paul Gilmartin
On Mon, 8 Jun 2009 19:23:51 +0300, Binyamin Dissen wrote: > >Most Fxx abends mean that you issued an undefined SVC, in your case D6 = 221 >which, if I recall correctly, is the acf2 default SVC number. > In case majority rules, I'm voting for 214. -- gil ---

Re: SDSF anomaly - z/OS migration from v1.7 to v1.9

2009-06-08 Thread R.S.
Mike Myers pisze: Hi: We are migrating to z/OS v1.9 and have gone from SDSF at HQX7720 to SDSF at HQX7740. Something has happened to the list of jobs that are viewable in the Held and Output queues under SDSF. Some jobs will not appear in either list (on z/OS v1.9 - SDSF at HQX7740) but will

Re: SDSF anomaly - z/OS migration from v1.7 to v1.9

2009-06-08 Thread Mike Myers
Radislaw: Thanks for the reply. I read the referenced web-page and don't quite understand the relevance. Is this implying that the absence of a POS value will prevent a job from appearing in the Held or Output displays? That's what I'm getting. If that's so, then what do I need to do to f

Broken link on web ibmlink

2009-06-08 Thread Gibney, Dave
I wanted to make my futile objection to the end of the tn3270 access, but feedback in not 3270 anymore and: https://www-304.ibm.com/ibmlink/feedback/feedbackPage.jsp?lc=en&cc=US The website cannot display the page HTTP 500 Most likely causes: * The website is under main

Re: Broken link on web ibmlink

2009-06-08 Thread Thompson, Steve
-Original Message- From: IBM Mainframe Discussion List [mailto:ibm-m...@bama.ua.edu] On Behalf Of Gibney, Dave Sent: Monday, June 08, 2009 12:50 PM To: IBM-MAIN@bama.ua.edu Subject: Broken link on web ibmlink I wanted to make my futile objection to the end of the tn3270 access, but feedbac

Re: What is System Completion Code FD6?

2009-06-08 Thread Scott Rowe
.. and the winner is: Steve Conway! I'm surprised that this August bunch of Sysprogs couldn't handle the Hex -> decimal conversion ;-) >>> Steven Conway 6/8/2009 12:24 PM >>> In QuickRef, do Categories, then System Abend Codes. Select any of the system abend codes Fxx: Fnn Explanation: Th

Re: What is System Completion Code FD6?

2009-06-08 Thread Steven Conway
Scott says I won - do I get a prize? Steve Conway Lead Systems Programmer Information Systems & Services Division Computer & Network Operations Phone: (703) 450-3156 Fax:(703) 450-3197 -- For IBM-MAIN subscribe / sig

Re: What is System Completion Code FD6?

2009-06-08 Thread Thomas H Puddicombe
Yeah, we all faxed you a beer. Tom Puddicombe Mainframe Performance & Capacity Planning CSC 71 Deerfield Rd, Meriden, CT 06450 ITIS | (860) 428-3252 | tpudd...@csc.com | www.csc.com This is a PRIVATE message. If you are not the intended recipient, please delete without copying and kindly advise

Re: Broken link on web ibmlink

2009-06-08 Thread Gibney, Dave
Yah, that was fun. Unfortunately, Ibmlink 3270 seems broken today also, at least AST and XREF from SIS. Dave Gibney Information Technology Services Washington State University > -Original Message- > From: IBM Mainframe Discussion List [mailto:ibm-m...@bama.ua.edu] On > Behalf Of Thomps

Re: EXEC Above the Bar (Was Large Page Support)

2009-06-08 Thread John R. Ehrman (408-463-3543 T/543-)
CSECTs are restricted to 16MB only if you generate traditional OBJ object files, because its length and address fields are 3 bytes long. As Peter said, the total length in a single assembly will be less than 16M. *BUT* if you specify the NOTHREAD option you can have as many very larget CSECTs as y

Re: Broken link on web ibmlink

2009-06-08 Thread Gibney, Dave
> -Original Message- > From: IBM Mainframe Discussion List [mailto:ibm-m...@bama.ua.edu] On > Behalf Of Gibney, Dave > Sent: Monday, June 08, 2009 11:24 AM > To: IBM-MAIN@bama.ua.edu > Subject: Re: Broken link on web ibmlink > > > Yah, that was fun. Unfortunately, Ibmlink 3270 seems bro

Re: What is System Completion Code FD6?

2009-06-08 Thread Schwarz, Barry A
I thought it was an amazing coincidence that so many hex calculators ran out of batter power at the same time. I guess I'll cancel the order to buy stock in Duracell. -Original Message- From: Paul Gilmartin Sent: Monday, June 08, 2009 9:39 AM To: IBM-MAIN@bama.ua.edu Subject: Re: What i

Re: What is System Completion Code FD6?

2009-06-08 Thread Hardee, Charles H
They were probably using the Windoze Calculator on an Intel Based Pentium PC. You know how accurate those CPUs are... -Original Message- From: IBM Mainframe Discussion List [mailto:ibm-m...@bama.ua.edu] On Behalf Of Schwarz, Barry A Sent: Monday, June 08, 2009 1:52 PM To: IBM-MAIN@bama.ua.

Re: How to synch MVS catalog to RMM CDS

2009-06-08 Thread John Mattson
Thanks for the reply. Catsynch does exactly the OPPOSITE of what I need. See Below. What I am trying to do is update the UCAT from RMM. When the RMM CDS entry has status YES, I want to create a UCAT entry. Looks like I will have to continue to do this manually, read the CDS, check the UCAT, c

Re: How to synch MVS catalog to RMM CDS

2009-06-08 Thread Amerigo Baldassarri
There is a product from Mainstar that can audit the catalog(s) tape entries against Removable Media Manager (RMM) database and build the necessary entries for you. I enclose a link https://www.mainstar.com/products/hsmt/fa390ste/ -Original Message- From: IBM Mainframe Discussion List

Re: How to synch MVS catalog to RMM CDS

2009-06-08 Thread Klein, Kenneth
IBM bought them all up. I just installed Tivoli advanced catalog management, advanced auditing and advanced reporting. Looks pretty slick. It will generate jcl for you to run to fix problems with mismatches and missing components in your bcds, mcds, and ocds. Ken Klein Sr. Systems Programmer ke

Re: What is System Completion Code FD6?

2009-06-08 Thread Ed Finnell
In a message dated 6/8/2009 1:52:40 P.M. Central Daylight Time, barry.a.schw...@boeing.com writes: out of batter power at the same time. I guess I'll cancel the order to buy stock in Duracell. >> My FX451 still ticking after all these years. Think the only thing that's failed is the x'e'

Fw: Wait under CICS

2009-06-08 Thread Bill Klein
ILBOWAT0 should not be used under CICS (but unfortunately will work - if LE is in the LPA). HOWEVER, CEE3DLY is available. See: http://publibz.boulder.ibm.com/cgi-bin/bookmgr_OS390/BOOKS/CEEA3190/2.2.5.5. 1 "Edward Jaffe" wrote in message news:<4a2bb7f4.3040...@phoenixsoftware.com>... > And

Re: SHOWzOS SHORT_PUTLINE

2009-06-08 Thread Marty Penhorwood
Can anyone tell me why I am getting an old (dated 3/2/2006) version of SHOWZOS when I download file #492 from cbttape.org? How do I get 7.18? -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists.

Re: SHOWzOS SHORT_PUTLINE

2009-06-08 Thread Farley, Peter x23353
Go to the "latest updates" page instead of the regular DL page. HTH Peter > -Original Message- > From: IBM Mainframe Discussion List [mailto:ibm-m...@bama.ua.edu] On > Behalf Of Marty Penhorwood > Sent: Monday, June 08, 2009 4:55 PM > To: IBM-MAIN@bama.ua.edu > Subject: Re: SHOWzOS SHORT

Re: SHOWzOS SHORT_PUTLINE

2009-06-08 Thread Marty Penhorwood
Ah. . . I just knew I wasn't going completely nuts. Thanks so much for the prompt assistance. Marty -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-

TCPIP config on z/OS 1.7 ADCD

2009-06-08 Thread Mark Wilson
Hi, Ignoring the ³It¹s not supported² issues I have a problem with zOS 1.7 and TCPIP.. I need to re-build the image from a backup of our ADCD system on our z890 to perform a set of tests for a customer. I am having an issue configuring TCPIP and was looking for some words of wisdom. Our IP

RMM How to manually change CATALOG STATUS in CDS

2009-06-08 Thread John Mattson
Looking at output from DFRMM CATSYNCH VERIFY I have found the following 1) EDG2233E DFSMSrmm CDS CATALOG STATUS NO FOR DATA.SET.NAME VOLUME 008662 FILE 1 CONFLICTS WITH CATALOG STATUS YES In "most" of these cases I just need to change the catalog status value. However, In the CHANGEVOLUME comm

Re: TCPIP config on z/OS 1.7 ADCD

2009-06-08 Thread Pommier, Rex R.
Mark, Here's a subsection of my 1.7 TCPIP.PROFILE.TCPIP with your addresses plugged into it. I am not using OMPROUTE and I would guess you don't need it either. I am also assuming you have 1 OSA adapter that you're using for this. DEVICE GIGADEV1 MPCIPA LINK

Re: IEFBR14 (was: EXEC Above the Bar)

2009-06-08 Thread Greg Price
Gilbert Saint-Flour wrote: > I also remember a special version of such a utility that was called IEFBR15. My version of IEFBR15 just looped. :) Cheers, Greg -- For IBM-MAIN subscribe / signoff / archive access instructions, sen

Re: IEFBR14 (was: EXEC Above the Bar)

2009-06-08 Thread Ted MacNEIL
>My version of IEFBR15 just looped. Some shops used it as a low priority soaker to ensure capture ratios. I always thought of it as a waste of effort. Not CPU, because it only used cycles nobody else needed. Of course, with today's 4HRA it would become a cost item. - Too busy driving to stop for

Re: SHOWzOS SHORT_PUTLINE

2009-06-08 Thread Roland Schiradin
Hi Ken, yes please email me PSW and REGS offline after you upgrade to version 7.18. Roland -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INF

Re: What is System Completion Code FD6?

2009-06-08 Thread Robert A. Rosenberg
At 11:24 -0500 on 06/08/2009, Field, Alan C. wrote about Re: What is System Completion Code FD6?: Look in the MVS System Codes document. Fnn are issued for errors detected in SVC nn (nn = X'D6' = 214) So you have an error from SVC 214. SVCs > 199 are typically USER SVCS. Figure out who provi

Re: IEFBR14 (was: EXEC Above the Bar)

2009-06-08 Thread Robert A. Rosenberg
At 10:24 -0400 on 06/08/2009, O'Brien, David W. (NIH/CIT) [C] wrote about Re: IEFBR14 (was: EXEC Above the Bar): I for one look forward to jobs which now take hours taking just a few minutes once we get to 1.11. Dave O'Brien NIH Contractor Of course the delay is due to a programmer error wi

Re: Book on Poughkeepsie

2009-06-08 Thread William Donzelli
> I do not think there was a sorter for the 96 column family - I never > saw anything like that in the directories, let alone real life. As far > as I know, there was the MFCU and a standalone keypunch, and nothing > else. Sorry to open up this thread again, but I just learned that the offline 96

Re: IEFBR14 (was: EXEC Above the Bar)

2009-06-08 Thread Hunkeler Peter (KIUP 4)
>Of course the delay is due to a programmer error with the JCL ... which is a result of the fact that the operating system doesn't offer a way to "delete, if present, then allocate new" in one step, something like DISP=(RENEW,CATLG). This would have avoided many of the unconditional IEFBR14s

Re: IEFBR14 (was: EXEC Above the Bar)

2009-06-08 Thread Gilbert Saint-Flour
On Tuesday 09 June 2009 08:27, Hunkeler Peter , KIUP 4 wrote: >>Of course the delay is due to a programmer error with the JCL > > ... which is a result of the fact that the operating system > doesn't offer a way to "delete, if present, then allocate new" in > one step, something like DISP=(R