Pennsylvania allowed for this tax exemption in the past. They have
recently changed the law. We were saving 6% on IBM and BMC software.
This was significant savings for a 5000 MIP shop. We didn't have any
issues downloading our software, including z/OS electronically. Back
when I discovered
Assuming you have directors, why not have all 6 channels defined to both
storage frames.
-Original Message-
We are on a countdown to move from a 2105-800 Shark to a 2107-921
DS8100. The motor is a z/890 2066-0A4. We are a 7x24 online shop with
some tight SLA's. All of our slack for years
View the device entry in HCD to determine if they are defined as
LOCANY=YES.
-Original Message-
From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On
Behalf Of Howard Rifkind
Sent: Thursday, June 29, 2006 2:19 PM
To: IBM-MAIN@BAMA.UA.EDU
Subject: Re: LinkList Space issue?
I have 2 CHPIDs connected to the same switch and accessing like devices.
Does anyone know the difference between TYPE 4 and TYPE 5? I can't
figure out why one shows as a type 4 and the other as a type 5.
04 ESCON SWITCH OR POINT TO POINTCNC_?
05 ESCON SWITCHED POINT-TO-POINT CNC_S
We have a expired HSM backup that we need to use for a recovery. We
know the tape and the relative FBID. We have backups available of the
three CDS files. But, we don't want to shutdown HSM. Does anyone know
how I can restore this file.
Thanks in advance,
larry
Disclaimer: This e-mail
You don't specify whether it is a MOD-9 in the IOGEN.
-Original Message-
Does anyone know how I would identify a 3390-9 in the HCD/IOGEN ?
Disclaimer: This e-mail message is intended only for the personal use of
the recipient(s) named above. If you are not an intended recipient, you
Can someone explain how WLM works if someone submits a job using a WLM
jobclass, but they don't specify a scheduling environment? Is there a
default scheduling environment? The job does run.
Disclaimer: This e-mail message is intended only for the personal use of
the recipient(s) named above.
Just type DEL next to the cluster.
-Original Message-
I would like to delete an IODF work dataset which I'm using to learn and
I know it's a liniar vsam dataset.
How do you go about deleting such a dataset.
Thanks
Disclaimer: This e-mail message is intended only
When installing a stand alone cf, is it necessary to write the IOCDS to
the standalone CF. I seem to recall that at activation of a standalone
cf, the cf control code is loaded with the installed links brought
online. Can someone that has implemented a standalone cf verify the
process.
I will be running z/OS 1.4 in 31 bit on z900 machines with ICFs. Can I
have more than 2GB defined as central storage on my ICF, even if the
z/OS lpars are still running 31 bit mode.
Larry Kraus
RiteAid Corp
717-214-8511
Disclaimer: This e-mail message is intended only for the personal use
Just curious how many companies are using third party providers for
their mainframe maintenance? If you are using someone other than IBM,
is anyone using QSGI?
Disclaimer: This e-mail message is intended only for the personal use of
the recipient(s) named above. If you are not an intended
Several years back we converted from TPX to Macro4's product called
TUBES. It works great and is cheap.
-Original Message-
I'd really appreciate any feedback regarding the listed products (and
any I may have missed).
Our use is simply to be able to jump between 3270 sessions and to be
I don't know what you mean by is it supported. A couple of years ago,
we converted our 3400 stores from SNA to TCPIP. We still have the
majority of our network tasks isolated to our 2 CMC lpars. So I would
say the answer is Yes. The main reason is what was mentioned earlier.
It runs separate
The CMC 'works' with TCP/IP.
-Original Message-
From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On
Behalf Of Ted MacNEIL
Sent: Thursday, August 04, 2005 8:00 PM
To: IBM-MAIN@BAMA.UA.EDU
Subject: Re: TCP/IP and CMC?
CMC Host or Communications Management Configuration Host,
So when I look at my IBM software list, I have the following:
COBOL Full Function Product Number - 5655G53
VS COBOL II Comp Lib and Debug Product Number - 5668958
Should I be able to drop the Debug from the VS COBOL II product?
Yes, you can pay IBM $5,000 to $10,000 dollars to make it an R16, R26,
etc.
-Original Message-
Hi Listers,
We have an IBM 9672-R56 hardware. Is there any way we can downsize it
to a lower capacity so that we can use it for testing.
We understand that IBM has dropped marketing
We use Cybermation's Alchemist.
-Original Message-
Hi,
I would like to have opinions on Mainframe (OS/390 z/OS) software
packages for change control when putting applications into production,
such as SCLM and Endevor.
Could anyone give me any opinions on pros and cons of SCLM, Endevor,
17 matches