Is there a __simple__ way to change the name of a SYSPLEX?

2008-02-28 Thread McKown, John
I am reading, but have no real experience. I have a single member sysplex right now. I need to split it into two z/OS images, in a basic sysplex. Due to stupidity on my part, I named the sysplex the same as the sysname. I would now like to change the name of the sysplex to something like PROD1. I d

Re: Is there a __simple__ way to change the name of a SYSPLEX?

2008-02-28 Thread Staller, Allan
Never had to do this myself, but: Why not create the "second" image in the "new" sysplex and populate your CDS's in the "new" sysplex". Migrate work to the "second" image in the "new" sysplex and then put the "current" image into the "new" sysplex with an IPL. I would expect this to be a minimal

Re: Is there a __simple__ way to change the name of a SYSPLEX?

2008-02-28 Thread R.S.
Not, nice but IMHO feasible: leave the names unchanged. Create second system with new name. You will have SYSPROD and SYSPRO2 belongind to sysplex SYSPROD. -- Radoslaw Skorupka Lodz, Poland -- BRE Bank SA ul. Senatorska 18 00-950 Warszawa www.brebank.pl Sd Rejonowy dla m. st. Warszawy XII

Re: Is there a __simple__ way to change the name of a SYSPLEX?

2008-02-28 Thread McKown, John
> -Original Message- > From: IBM Mainframe Discussion List > [mailto:[EMAIL PROTECTED] On Behalf Of Staller, Allan > Sent: Thursday, February 28, 2008 1:06 PM > To: IBM-MAIN@BAMA.UA.EDU > Subject: Re: Is there a __simple__ way to change the name of > a SYSPLEX? &g

Re: Is there a __simple__ way to change the name of a SYSPLEX?

2008-02-28 Thread Mark Zelden
On Thu, 28 Feb 2008 12:47:41 -0600, McKown, John <[EMAIL PROTECTED]> wrote: >I am reading, but have no real experience. I have a single member >sysplex right now. I need to split it into two z/OS images, in a basic >sysplex. Due to stupidity on my part, I named the sysplex the same as >the sysname

Re: Is there a __simple__ way to change the name of a SYSPLEX?

2008-02-29 Thread Arthur Gutowski
>Here are the notes for exactly what I did: >1) Defined / formatted new XCF, WLM, and LOGR couple data sets using new data set and sysplex names >2) Extracted / Saved current WLM policy into a PDS prior to IPL >3) Deleted CICS logstreams (DASDONLY) prior to IPL. >4) Stopped RRS and deleted RRS log