Re: Using CSVINFO

2007-12-17 Thread David Day
: Using CSVINFO It doesn't on my system. Bit is not set in the MODI data area returned. That is extremely unlikely, close to impossible. You likely have some other coding error. The information about it is an alias AKA minor is copied directly from the CDE (for active LPA) or LPDE (for PLPA

Re: Using CSVINFO

2007-12-05 Thread Walt Farrell
On Tue, 4 Dec 2007 16:37:52 -0600, David Day [EMAIL PROTECTED] wrote: TMMODI_ATTR2,MODI_MINOR IS THIS A MINOR ENTRY POINT BZGTLP0550NO ICM R4,15,MODI_5_PTRGET PTR TO MODI_5 DSECT BZGTLP0550NO MINOR ENTRY USING MODI_5,R4 MVC

Re: Using CSVINFO

2007-12-05 Thread David Day
, 2007 11:13 AM Subject: Re: Using CSVINFO It doesn't on my system. Bit is not set in the MODI data area returned. That is extremely unlikely, close to impossible. You likely have some other coding error. The information about it is an alias AKA minor is copied directly from the CDE (for active

Re: Using CSVINFO

2007-12-05 Thread Peter Relson
It doesn't on my system. Bit is not set in the MODI data area returned. That is extremely unlikely, close to impossible. You likely have some other coding error. The information about it is an alias AKA minor is copied directly from the CDE (for active LPA) or LPDE (for PLPA). It is not

Re: Using CSVINFO

2007-12-05 Thread David Day
in the MIPR entry. - Original Message - From: Walt Farrell [EMAIL PROTECTED] Newsgroups: bit.listserv.ibm-main To: IBM-MAIN@BAMA.UA.EDU Sent: Wednesday, December 05, 2007 9:48 AM Subject: Re: Using CSVINFO On Tue, 4 Dec 2007 16:37:52 -0600, David Day [EMAIL PROTECTED] wrote: TM

Using CSVINFO

2007-12-04 Thread David Day
Based upon a fairly recent discussion here on IBM-Main, I've changed my code to now use CSVINFO(as opposed to using LPDE's) to identify modules in the PLPA. The macro is coded CSVINFO FUNC=LPA,ENV=MVS. My MIPR routine is getting called with a MODI data for both alias and real load modules,

Re: Using CSVINFO

2007-12-04 Thread Robert Wright
David Day wrote: Based upon a fairly recent discussion here on IBM-Main, I've changed my code to now use CSVINFO(as opposed to using LPDE's) to identify modules in the PLPA. The macro is coded CSVINFO FUNC=LPA,ENV=MVS. My MIPR routine is getting called with a MODI data for both alias and

Re: Using CSVINFO

2007-12-04 Thread David Day
It doesn't on my system. Bit is not set in the MODI data area returned. - Original Message - From: Robert Wright [EMAIL PROTECTED] Newsgroups: bit.listserv.ibm-main To: IBM-MAIN@BAMA.UA.EDU Sent: Tuesday, December 04, 2007 2:34 PM Subject: Re: Using CSVINFO David Day wrote: Based

Re: Using CSVINFO

2007-12-04 Thread Robert Wright
David Day wrote: It doesn't on my system. Bit is not set in the MODI data area returned. - Original Message - From: Robert Wright [EMAIL PROTECTED] Newsgroups: bit.listserv.ibm-main To: IBM-MAIN@BAMA.UA.EDU Sent: Tuesday, December 04, 2007 2:34 PM Subject: Re: Using CSVINFO See

Re: Using CSVINFO

2007-12-04 Thread David Day
dsect. It's not working on my system. I've got a Flex machine, running z/OS 1.6. - Original Message - From: Robert Wright [EMAIL PROTECTED] Newsgroups: bit.listserv.ibm-main To: IBM-MAIN@BAMA.UA.EDU Sent: Tuesday, December 04, 2007 4:21 PM Subject: Re: Using CSVINFO David Day wrote