On 9/03/2021 6:45 am, Andrew Rowley wrote:
On 9/03/2021 12:42 am, Lionel B Dyck wrote:
It appears that on one of my z/OS 2.4 systems I don't have this ssh
issue but on another I do. The difference is that one has a
/etc/ssh/zos_ssh_config file and the one that fails does not.
Updating the
Brian Westerman wrote:
>Next, using CICS, DBV2 or IMS serverpac as a sample/example.
>There are a great many sites who do not have CICS or DB2 or
>IMS, I can name 30 just off the top of my head. How will
>they "practice"? How will they "learn the process now?"
>Are you penalizing them because
If all top-halfs are zero, it skips them.
On Wed, 10 Mar 2021 00:28:07 -0500 Tony Thigpen wrote:
:>I just noticed something I had not noticed before.
:>
:>I have a little test program that I am doing all sorts of things to see
:>how things work. So, of course, I am crashing it a lot. Sometimes
I just noticed something I had not noticed before.
I have a little test program that I am doing all sorts of things to see
how things work. So, of course, I am crashing it a lot. Sometimes even
on purpose using DC x'' instructions.
What I have noticed is that the log shows the registers
W dniu 09.03.2021 o 18:21, Paul Gilmartin pisze:
On Tue, 9 Mar 2021 12:42:34 +0100, Radoslaw Skorupka wrote:
Striped PS datasets (extended format PS) are managed by IEBGENER,
ICEGENER or IDCAMS as regular (non-striped) datasets. I mean user
perspective.
In other words, transparent to the
SET BDY(TARGET).
LIST PTFS
FORFMID(HTCZ110).
SET BDY(DLIB).
LIST PTFS
FORFMID(HTCZ110).
For running the mepl can that be run against the Query monitor load and NOT the
DB2 DSNLOAD?
thanks
Bill
--
For
I hope this isn't considered advertising if it's for a free product, but we'd
like to announce our new WWUNTERSE (no-charge) product.
Here at Watson & Walker we love SMF data. And judging by the volumes of it
that most z/OS sites generate, we are not the only ones. SMF can tell you just
Hi Marna, I will respond in a different order.
As for staying "current", yes, that would be a good idea, unfortunately, it's
unrealistic to decide it has to be that way. I would imagine a very large
number of sites are still running 2.1 and 2.2, in fact, I know that to be true.
Next,
Technically TSSO still works, but obviously there are parts that no longer are
needed.
Even though it's technically a slight competitor of our (far superior)
automation package, I still make sure to test it and make changes when
necessary, as have a handful of others, and it still works on
Please show the commands that you ran and the output that you received.
--
Shmuel (Seymour J.) Metz
http://mason.gmu.edu/~smetz3
From: IBM Mainframe Discussion List [IBM-MAIN@LISTSERV.UA.EDU] on behalf of
Bill Giannelli [billgianne...@gmail.com]
Sent:
If your CSI doesn't match your target and distribution libraries then you have
big problems. If they do match, then you can get the service applied from SMP
without looking at the libraries. Note that some service might not hit any load
libraries at all.
--
Shmuel (Seymour J.) Metz
On Mon, 8 Mar 2021 18:08:55 -0800, Tom Sims wrote:
>Any one out there running TSSO (CBT File 404) under zOS 2.3?
>
I was running it prior to the console restructure broke it circa 1.11 or
1.13(?). I think I heard that it had been updated to run on later releases
though.
Dana
Thank you Sri, that worked!
Peter
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of Sri
h Kolusu
Sent: Tuesday, March 9, 2021 12:56 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: SORT syntax question
> What is the correct syntax to find and replace all binary zeroes in
In the below output paste, the "*" indicating the syntax error is placed under
the comma at the end of the third line (after the first ENDPOS parameter and 2
closing parentheses).
This is Syncsort, not DFSORT, but the FINDREP syntax is (or anyway ought to be)
common between them.
> What is the correct syntax to find and replace all binary zeroes in
> positions 1-34 with spaces and replace all X'41' characters by
> spaces in positions 35-94 and do *both* FINDREP's only when position
> 13 is C'D'?
Peter,
You need two separate IFTHEN statements as you have different START
Could you post the error messages?
Lizette
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of
Farley, Peter x23353
Sent: Tuesday, March 9, 2021 10:48 AM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: SORT syntax question
This format of FINDREP's on an INREC command gets a
But -- if you want to bring the CSI up to the current ptf level - you need to
know what PTFs have been deployed to the subsystem - interrogating the load
library is the only way I know to do that - either mepl or AMBLIST
Chris Hoelscher
Lead Sys DBA
IBM Global Technical Services on assignmemt
This format of FINDREP's on an INREC command gets a syntax error:
IFTHEN=(WHEN=(13,1,CH,EQ,C'D'),
FINDREP=(INOUT=(X'00',C' '),
STARTPOS=01,ENDPOS=34)),
FINDREP=(INOUT=(X'41',C' '),
STARTPOS=35,ENDPOS=94)),
What is the correct syntax to find and replace all binary
Bill,
There is
https://community.ibm.com/community/user/imwuc/communities/community-home?CommunityKey=183ec850-4947-49c8-9a2e-8e7c7fc46c64
You can contact me off line, as I used to work in MQ development/support
regard
Colin
On Tue, 9 Mar 2021 at 14:55, Bill Giannelli wrote:
> Hello,
> We
On Tue, 9 Mar 2021 12:42:34 +0100, Radoslaw Skorupka wrote:
>
>Striped PS datasets (extended format PS) are managed by IEBGENER,
>ICEGENER or IDCAMS as regular (non-striped) datasets. I mean user
>perspective.
>
In other words, transparent to the utility or user program, with at
most changes to
Hi Chris,
thanks for your help!
Its the SMPe CSI I am concerned with not the actual load library.
Bill
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message:
Run a MEPL to see what the load modules indicate maintenance has been appled
//STEP9991 EXEC DSNUPROC,UID='ssid.MEPL',
//UTPROC='',SYSTEM='ssid'
DIAGNOSE DISPLAY MEPL
DIAGNOSE END
Chris Hoelscher
Lead Sys DBA
IBM Global
I have a SMPe CSI that shows products installed (5655-TC1 fmid HTCZ110) and
(5655-V42 fmid HCQC110). IBM Tools Customizer and IBM Query Monitor for DB2.
Yet when I try to run a report of sysmods in either my target or DLIB it show
no sysmods found. How do I remedy this? Do I reorder the
http://www.mqseries.net/phpBB2/index.php?
On Tue, Mar 9, 2021 at 09:55 Bill Giannelli wrote:
> Hello,
> We are trying to debug old MQ code.
> Can anyone point to some places to get MQ information? Is there a
> "IBM-Main" for MQ?
> We need to find the equivalent of the SQLCA area "Bind" command
Hello,
We are trying to debug old MQ code.
Can anyone point to some places to get MQ information? Is there a "IBM-Main"
for MQ?
We need to find the equivalent of the SQLCA area "Bind" command and a
programming guide..
thanks
Bill
ChannelConvert shell,exec -- is the default.
I do see this in the documentation:
/This option should not be used globally in zos_ssh_config since
changing conversion options for channel types (for example, "subystem"
or "exec") could cause sftp, scp, and other exec connections to fail.
The
W dniu 08.03.2021 o 18:42, Paul Gilmartin pisze:
On Mon, 8 Mar 2021 11:15:56 -0600, Nigel Morton wrote:
Have you considered using extended format sequential striped data sets?
Define using a data class with DSNTYPE set to require or request extended
format; control the number of stripes
27 matches