Re: Monitor Configuration Records

2008-01-04 Thread Rob van der Heij
On Jan 4, 2008 2:10 PM, Dixon, Patricia A [EMAIL PROTECTED] wrote: does that mean Domain 1/6 records will not be collected? Is there any other reason why 1/6 records would not be created? Sample configuration area too small -Rob

AW: z/VM 5.2 Absurd System shutdown - PJBR

2008-01-04 Thread Fritz, Wilhelm
Thanks for the clarification, Rob. I didn't know that. Willy -Ursprüngliche Nachricht- Von: The IBM z/VM Operating System [mailto:[EMAIL PROTECTED] Auftrag von Rob van der Heij Gesendet: Freitag, 4. Januar 2008 14:17 An: IBMVM@LISTSERV.UARK.EDU Betreff: Re: z/VM 5.2 Absurd System

Re: z/VM 5.2 Absurd System shutdown - PJBR

2008-01-04 Thread Stracka, James (GTI)
Starting at cylinder 0 is Okay. Not normally done but has been acceptable for over 20 years. We used to do that with SPOOL volumes back in the day when DASD was expensive. -Original Message- From: The IBM z/VM Operating System [mailto:[EMAIL PROTECTED] On Behalf Of Fritz, Wilhelm

z/VM 5.2 Absurd System shutdown - PJBR

2008-01-04 Thread Jose Raul Baron
Hi, list. We are experiencing some problems with unpredictable and so far inevitable system shutdowns for aparently unknown reasons. - We are running 4 SLES9 Linux images under z/VM 5.2 - If we keep only 3 images, this problem doesn't seem to appear. It has happened only with 4 images running

Re: z/VM 5.2 Absurd System shutdown - PJBR

2008-01-04 Thread David Boyes
xx:yy:zz HCPPAW415E Six continuous paging errors have occurred on DASD 02D5 volume 520PG1. (this message appears some 25-30 times per second) Did you recently add some page space to the system, or possibly overlapped some of your paging or spool space with a minidisk? This

Re: z/VM 5.2 Absurd System shutdown - PJBR

2008-01-04 Thread Rob van der Heij
On Jan 4, 2008 1:32 PM, David Boyes [EMAIL PROTECTED] wrote: Did you recently add some page space to the system, or possibly overlapped some of your paging or spool space with a minidisk? This message can be caused by forgetting to format the page space with ICKDSF, or if you've accidentally

Re: Monitor Configuration Records

2008-01-04 Thread Rob van der Heij
On Jan 4, 2008 3:31 PM, Dixon, Patricia A [EMAIL PROTECTED] wrote: If I see a 1/11 which tells me I have a complete set of configuration records, why am I not seeing the 1/6? I am also seeing other configuration records too, such as the 1/15 (user) and 1/8 (paging) in the monitor data I'm

Monitor Configuration Records

2008-01-04 Thread Dixon, Patricia A
Hello, When setting up the MONITOR profile to collect data, can certain configuration records (specifically the 1/06 Device) be disabled or be prevented from being created? If so, which other configuration records can be disabled? I checked the CP Commands and Utilities Reference, MONITOR

AW: z/VM 5.2 Absurd System shutdown - PJBR

2008-01-04 Thread Fritz, Wilhelm
Why does your paging device start on cyl 0?!?: -- PAGE AREAS == EXTENT EXTENT TOTAL PAGES HIGH% VOLID RDEV STARTEND PAGES IN USE PAGE USED

Re: Monitor Configuration Records

2008-01-04 Thread Dixon, Patricia A
Hi, If I see a 1/11 which tells me I have a complete set of configuration records, why am I not seeing the 1/6? I am also seeing other configuration records too, such as the 1/15 (user) and 1/8 (paging) in the monitor data I'm analyzing but no 1/6. Thanks, Pat -Original Message-

DB2/VSEVM V7.50 manuals

2008-01-04 Thread Roland P. Chung
Hi Listers, DB2/VSEVM V7.50 manuals are online at: http://www-306.ibm.com/software/data/db2/vse-vm/directory.html Regards, ...Roland

Re: z/VM 5.2 Absurd System shutdown - PJBR

2008-01-04 Thread Kris Buelens
2008/1/4, Rob van der Heij [EMAIL PROTECTED]: On Jan 4, 2008 1:32 PM, David Boyes [EMAIL PROTECTED] wrote . I believe DIRMAINT already blocks CP areas from allocation these days, even when you don't do $PAGE$ and $SPOL$ userids. But for those shops without, wibni CP would prevent lesser

Re: AW: z/VM 5.2 Absurd System shutdown - PJBR

2008-01-04 Thread Aria Bamdad
Cylinder zero is ok for other CP areas but NOT for TDISK. Don't define a TDSK area on cylinder zero. Aria. On Fri, 4 Jan 2008 14:29:15 +0100 Fritz, Wilhelm said: Thanks for the clarification, Rob. I didn't know that. Willy On Jan 4, 2008 2:09 PM, Fritz, Wilhelm [EMAIL PROTECTED] wrote: Why

Re: Alternate cylinders and new DASD

2008-01-04 Thread Stracka, James (GTI)
Probably not. If so, only for some very old formatted VM DASD. -Original Message- From: The IBM z/VM Operating System [mailto:[EMAIL PROTECTED] On Behalf Of Leland Lucius Sent: Friday, January 04, 2008 11:07 AM To: IBMVM@LISTSERV.UARK.EDU Subject: Alternate cylinders and new DASD We're