On Tuesday, 12/28/2010 at 04:08 EST, George Henke/NYLIC
george_he...@newyorklife.com wrote
On Wed, 29 Dec 2010 01:40:01 -0500 Alan Altmark said:
On Tuesday, 12/28/2010 at 04:08 EST, George Henke/NYLIC
george_he...@newyorklife.com wrote:
Our Supersession boys swear it is not Superseesion.
Could it be the Coupling Facility Service Machine doing it?
George, the Coupling Facility is not
How do I stop DIAL from turning off the Extended Data Stream (EDS)
terminal attribute?
I have NSX32702 Logmode (NSX means Non-SNA EDS) before dialing my z/OS
guest.
The ISPF ENVIRON TERMSTAT Query on native z/OS shows:
ISPF TERMINAL CHARACTERISTICS
14 BIT ADDRESSING= ON
16 BIT
The SPECIALs use a Coupling Facility Service Machine:
SPECIAL 420 MSGP CFSRV04
SPECIAL 424 MSGP CFSRV01
SPECIAL 428 MSGP CFSRV05
USER CFSRV04 CFSRV04 256M 2G G
XAUTOLOG CFCONSOL SY79TEST SY80TEST
*LA= 02:31:12 EST Sunday 10/31/99 by AUTOLOG1
OPTION CFVM TODENABLE QUICKDSP
*ED= 99/10/31
A general rule of z/VM is that it will never change the type of a device, so
DIAL will not change the 3270 characteristics (even though after DIAL it
will appear as a local non SNA 3270)
After you DIAL to z/OS, your 3270 gets another address. You need to find
the definition of that address in
by: The IBM z/VM Operating System IBMVM@LISTSERV.UARK.EDU
12/28/2010 02:20 PM
Please respond to
The IBM z/VM Operating System IBMVM@LISTSERV.UARK.EDU
To
IBMVM@LISTSERV.UARK.EDU
cc
Subject
Re: Stopping DIAL From Stripping Extended Data Stream
A general rule of z/VM is that it will never
...@gmail.com
Sent by: The IBM z/VM Operating System IBMVM@LISTSERV.UARK.EDU
12/28/2010 02:20 PM
Please respond to
The IBM z/VM Operating System IBMVM@LISTSERV.UARK.EDU
To
IBMVM@LISTSERV.UARK.EDU
cc
Subject
Re: Stopping DIAL From Stripping Extended Data Stream
A general rule of z/VM
Operating System IBMVM@LISTSERV.UARK.EDU
12/28/2010 02:20 PM
Please respond to
The IBM z/VM Operating System IBMVM@LISTSERV.UARK.EDU
To
IBMVM@LISTSERV.UARK.EDU
cc
Subject
Re: Stopping DIAL From Stripping Extended Data Stream
A general rule of z/VM is that it will never change the type
...@newyorklife.com
Sent by: The IBM z/VM Operating System IBMVM@LISTSERV.UARK.EDU
12/28/2010 03:06 PM
Please respond to
The IBM z/VM Operating System IBMVM@LISTSERV.UARK.EDU
To
IBMVM@LISTSERV.UARK.EDU
cc
Subject
Re: Stopping DIAL From Stripping Extended Data Stream
Our Supersession boys swear
On Tuesday, 12/28/2010 at 04:08 EST, George Henke/NYLIC
george_he...@newyorklife.com wrote:
Our Supersession boys swear it is not Superseesion.
Could it be the Coupling Facility Service Machine doing it?
George, the Coupling Facility is not involved in managing 3270 data
streams.