Re: [j-nsp] sonet/sdh parameters

2007-06-07 Thread Guy Davies
You could also take a quick look at http://www.tek.com/Measurement/App_Notes/sdhprimer/anomalies.pdf which gives some useful info on SDH anomalies. Rgds, Guy On 07/06/07, Guy Davies <[EMAIL PROTECTED]> wrote: > hi, > > RS-BIP8 is the Regenerator Section B1 Byte to provide end-to-end > performanc

Re: [j-nsp] sonet/sdh parameters

2007-06-07 Thread Guy Davies
hi, RS-BIP8 is the Regenerator Section B1 Byte to provide end-to-end performance monitoring on a single regenerator section. MS-BIP24 is the Multiplex Section B2 Bytes to provide error monitoring on the multiplex section. MS-FEBE is the Multiplex Section Far End Block Error (aka Remote Error Ind

[j-nsp] sonet/sdh parameters

2007-06-06 Thread snort bsd
hi all: i have some questions regarding some parameters of sonet/sdh: 1) what is RS-BIP8 2) what is MS-BIP24 3) what is MS-FEBE i found an old post from marcin; he really explained the HP-FEBE and HP-BIP8 very well. it would be great if some can also give out sources for those parameters. thank