Scott Serlin [EMAIL PROTECTED] wrote:
Let me try it. I've been trying to right-click the case statement and
not the while loop. This appears to be an oops on my part.
Cases don't have shift registers and so doesn't the event structure. You
only get tunnels and they are created automatically
I have some VI's that were writen with an old version of LabView(ver.
3.1).when I try to open them I get an error message that the file is
to old. How can I convert those file's for thay can be read with
version 6.1 of LabView.
Thank you and have a nice day
I was troubled by the reading/writing from parallel port on win2000
for a long time. I had made my programs work on win2000/OLD PC, but i
failed with the same programs on win2000/new PC. I tried with the
method from the forum, that is, install accessHW and other method from
my colleagues. Allways
Hi!
I need to insert in a VI something like the Tools palette, that can
be anabled or disabled via menu programmatically. The behavior should
be the same as the Window--Show Tools palette option in LabVIEW front
panel menu: the main VI continue running and performing his tasks, and
when a menu
Thanks Greg!
I have labview 7 express pro, but i dont find the application builder,
in the custom install i dont see it neither. Is application builder
into this cd?.
thanks.
The method you give us to make the serial working is fine , but when I
try to build my VI with application builder and then try to run the
exe it tells me that it cannot run the serial part ! so i cannot use
it whith exe .
Is there something to do before building the exe ?
Hi Shai,
Details of the conversion kit can be found here:-
http://digital.ni.com/public.nsf/3efedde4322fef19862567740067f3cc/429e45271cfd683786256d87006b1eef?OpenDocument
Hope this helps,
Nick
Hi,
On NT/2000/XP, you will not be able to use the serial port,
once it is assigned to a mouse.
On 95/98/Me, you can do this, but you will lose the mouse
for the remainder of your Windows session.
Mouse output is not very useful for tests anyway.
Get an (old) external modem for your first tests,
Hi Ben,
thanks for your answer and the interesting link. But I think I have
the direct inverted problem to yours: You had the problem that a dll
called from VB runs in a different memory space than LV, so you have
no direct access to your LV application. But my problem is that a dll
called from
Subramanian, Shankar, K [EMAIL PROTECTED] wrote:
Thanks for your reply. I think I will stack them avoiding the scrollbar as I
would not need all the buttons to be visible. But just curious to know, is
there any way of automating scrollbar depending on the window?
You don't work with the
[EMAIL PROTECTED] wrote:
when unflatting certain binary datas with Unflatten fromString (LV7) I
get an error msg window Nicht genügend Speicher zum Abschließen dieser
Operation (* not enough memory to close this operation). The error-output
of the vi is incorrect.
Does anybody know a workaround
Albert,
I'll stay with English so everyone on the list can follow...
You aked on Mon, 12 Jan 2004 16:04:03 +0100:
when unflatting certain binary datas with Unflatten fromString (LV7) I
get an error msg window Nicht genügend Speicher zum Abschließen dieser
Operation (* not enough memory to
Thank you for your comments to my problem.
You are right, I better should ad a versionnumber to my binary datas, to
read them back with correct type defininition.
But nevertheless I think, the unflatten from string vi must react
resonable when it gets a corrupted flattened string.
Obviously LV7
First Randomizer on internet with MONEY BACK GUARANTEE only $2 TO JOIN .
Visit: http://www.rockmyway.com/[EMAIL PROTECTED]
I've made $152.00 in 3 days so can you, Join me now and make some serious
Now I feel the propositions are right and I get a clear idea. Thank
you Nirmal Sharma, Dennis Knutson and Greg McKaskle.
HI... everybody,,,
I'd like to answer my question. Can u believe that I play around this
problem for 2 weeks. Then I design to use Matlab code in which it
works.
And at the end I realize that all of the problem only because of the
data file that I load (I use German window which in Germany use
I am interested in your final solution!
Please keep us updated.
Ben
I think your propositions are right. Now, I get a clear idea of the
qustion. Thank you.
It's integrated with LabVIEW. On the menu, go to ToolsBuild
Application or Shared Library
when I click it, the words (letters) on it can become bold, and when I
click it again, the words (letters) on it can be changed to be not
bold;
There are two things to worry about here. How do you get the visual
feedback you want, and how do you detect the action. Detecting the
action is
I believe that the specifics are that a DLL of the exact same version of
LV doesn't need to load the runtime into the LV dev environment. A DLL
built with a different version of LV will load the appropriate runtime,
since that is the version that the VIs must have.
So this doesn't help much
I'm looking for a VI that does the reverse job of the
Format Date/Time String, i.e. converts a string with a date
and a time, and with an time format-string input that describes
the format of the string, and gives a time stamp as output.
Anybody done this one ?
Martin
Here is an article from a recent Control Engineering newsletter...
SoftWire's patent infringement lawsuit against NI to proceed
Middleboro, MAMeasurement Computing Corp. and SoftWire Technology
Inc. recently announced that the U.S. District Court in Boston granted
on Nov. 5, 2003, the two firms'
Utilities is spelled differently.
RL -- I will make a note of this to look into the next time we revise
this manual.
If you have feedback on any National Instruments documentation, you
can send it to [EMAIL PROTECTED]
Thank you,
Kelly Holmes
National Instruments
I typically stay away from Dell PC's. I always have problems with
them..
I'm surprised to read that a new PC doesn't support Win-98. Have you
/ can you try Win-NT 4?
I can't understand why Win2K would be different with a newer PC. The
OS assigns the base address of the parallel port to a
So... I just change , to . and everything works fine.
with spline function in Matlab and spline in Labview itself.
Sorry it took so long to find the answer. For future reference, the
Tools Options dialog has an option to use the localized decimal in the
Front Panel page. This should make
copying shapes and stick them x times after knowing that one will
differemment modify the color of each shape, I have Imaq Vision
Builder
Thank you for your replies.
We have an embedded application with touch screen. The application is
designed with LV5.1 and runs under WindowsNT.
Currently we are porting the application to Linux. We want to hide the
cursor, just like we did for WindowsNT.
Is it also possible to change the cursor
Some of the newer PCs (some DELLs included) have the parallel port
disabled to free up some resources for other things in the system.
Check in the BIOS (during boot) and ensure that the parallel port is
enabled. Can you check the port with a parallel printer (or some other
device)?
Rob
Very simple; just wire the string to a scan from string function and
extract the month, day, year, hours, minutes and seconds as separate
numbers.
Now the date/time to seconds function takes a cluster of these numbers
and converts it to a timestamp so all you need is to bundle the
numbers into
If you use the serpdrv driver you must copy this file into the same
folder where your exe is located. This is and was neccessary with all
LV versions.
Waldemar
Thanks for ur good solution for my OS.., Greg McKaskle
Under labview, i read a file which contains to columns of data
(float64) and generate two 1 dimensional array which i want to add.
I want to add these two arrays in a CIN. I have no problem to compile
the CIN DLL. But i problem to work with array in a CIN. What is the
structure which is correspond
Hey Nick,
Please check out my response to your message in the Instrument
Connectivity/GPIB forum.
Scott
I tried your second suggestion, with setting threshold and then
inverting the array. It worked great, thanks for the help!
Hi
I tried to install the OpenG toolkit. But when i start it, it is missing
the Read BMP File.vi and some other vi's from the Graphics Sound
palette which is not included in the Base Version of LV 6.1. Has anyone
tried to fix and use it with the base version?
Frank
Hello:
I'm playing around and learning LabView. I bought a copy of LabView 6i
Student Edition and found that it didn't support the advanced data
acquisition instruments (I wanted to used the continuous data
acquisition example and it wouldn't work). Does anyone out there know
if the new Labview 7
Greetings,
There are a variety of documents on our website that contain
information about using the AMUX-64T with an MIO device. There are
also example programs that show how to acquire readings using an MIO
device with the AMUX-64T. I have linked to some of better documents
below as well as
OK,
After reading Greg's response and thinking a bit, I do have a (rather
cumbersome) work-around. Here goes;
LV does a wonderful job of keeping tarck of all those nasty little
details like what VI is really being called and are buffers allocatoed
correctly, etc, etc.
In your case, this is
Hello all,
I need your help! I'm adjusting, for someone else, a program built by
someone else! :-S,
first let me discribe the problem:
I have a Main VI with 5 subVI's in the Main menu (Main VI) a Bolean
turns a Case structure False or True(5 times for the 5 subVI's), in
this Case structure
Some times I am puzzled with 16Million color to code my subvi's ICONs.
I wonder if there is a Color-coding convention that I could use to
specify the right color for my subvi's. If someone has figured out a
way to do that please let me know.
Hello Albertz,
This definitely looks interesting.
As with any potential bug, I would recommend contacting National
Instruments tech support directly via email or phone (www.ni.com/ask)
so that they can document and take action on the problem.
Liz F
Yes, I used MAX. The GPIB card shows up there. So does the GPIB
instrument. I tried to test the interface with the communicate with
device button. The query just timed out. We un-installed the GPIB
card and then re-installed it. We un-installed all LV programs and
then re-installed LV6.1.
Greetings,
I am not that familiar with bioimpedance and tetrapolar probes, but I
do have experience with NI ELVIS. To me, it seems as if you are
looking for something with two current outputs and two voltage inputs.
If you have two constant current outputs to excite something (in your
case
I believe the Student Edition of 7 is fully functional. It adds a tag
in the lower left corner of the windows identifing it as the student
edition.
To be sure, you should call NI support and verify.
Ed
Two things you could try.
Drop a property node and set the VI Server Class to 'VI'. Then select
as the property either Front Panel WindowIs Frontmost and create a
false constant for the property or Front Panel WindowState and
create a constant and set it to Minimized.
Run this property node
Actually, the colors for icons are quite limited, the max. is 256
colors.
If you move around the color bars, watch the RGB indicator in the
palette. It is quite quantized.
Typically, I stay with a few simple colors. To make sure they are
exact, I do the 16 color icon (middle) first, then convert
I really like the idea of the tab indicator instead of stacking invisible
controls. Great idea! I learn something new everyday.
Kelly Bersch
Senior Technician
Anadigm
Telephone:480-344-5262
Email: [EMAIL PROTECTED]
http://www.Anadigm.com
Anadigm - The Programmable Analog
Shankar,
You wrote:
... Is there a way I can
open a subVI FP, at particular coordinates or something similar to that such
that it always shows Start and does an automatic scrolling?
And Kelly responded:
It looks like you can use a property node for the VI and select the property
Front Panel
I should have included the link to the original article. Here it is:
http://email.controleng.com/cgi-bin2/DM/y/efVG0GDREC0GXT0B6Ni0An
John Howard [EMAIL PROTECTED] 01/13/04 09:00AM
Here is an article from a recent Control Engineering newsletter...
SoftWire's patent infringement lawsuit
I created my VI on my laptop, and when I transfered and tried to open
the VI file from my local PC, it keeps giving me a dialog box asking
me to select the fileover and over and over again. Are there some
other hidden files that are associated w/ the VI? Or is it all rolled
into one?
Thanx for the answer.
I don't know the lib neither the stuctures of the user.lib directory.
I unpacked like this:
user.lib/
oglib_appcontrol-2.1-1/
oblib_array-2.0-1/...
In the toolspalette there are many question marks.
Now I downloaded OpenGoop. But the examples doesn't
I would like to see a dynamic controls palette that accumulates the Last
Used controls and functions. This is similar to Excels formula browser
interface which shows a list of the Last Used functions at the top. I
would be nice to make this somewhat customizable so I can load things into
by
There are no hidden VI's, but there may be some sub-vi's on your
laptop that are not on your desktop.
These could include any sub-vis you created on you laptop and any
extra LabVIEW toolkits or drivers (NI-DAQ) that you installed on the
laptop.
If it's toolkit or driver VIs that are missing,
I'm using LV 7.0 and when I try to use the 'Easy Text Report.VI' I get
this: Error -2147319779 occurred at library not registered. in font
styoe.vi-set report font.vi-easy text report.vi-untitled 1. This
error code is undefined. No one has provided a description for this
code, or you migh have
I am not familiar with BCH, however you can call C DLLs in LabVIEW as
well as Matlab.
So you could compile thier C code into a DLL and call it using the
Call Library Function Node. For more information on that refer to a
Ok, than I will try this.
Thx for the help
Frank,
I would recommend modifying your OpenG Package Installer. Simply
remove the missing VIs and output default values (null pictures).
Then you can use the package installer.
-Jim
Thank you, Ben and Greg, for your effort. But my solution for now is
not to use DLLs. I have only little time left for my project, so I
can't spend any time in this problem.
But to the idea with the wrapper VI: I don't believe that this would
help, because even the wrapper VI will run in the same
I should have mentioned in my post that I don't have easy access to a
C compliler. That's really where my problem lies.
thanks,
-dave
I have a XY graph with the X data spaced every 0.2 (0.00, 0.20, 0.40,
etc.). After I display the graph I use the curser to manually (by eye)
find the inflection point in the curve (ex. 1.46). I would like the
software to determine the inflection point on its own, but LabView
only sees the array of
I understand time limits!
I was not clear. I meant wrap a call libray function configure to
use the VI in the DLL.
My fault, please forgive.
Ben
How many digit precision do you get when running your vi?
The asterisks may only appear to indicate that you are in remote mode.
The precision shouldn't change. Have you tried displaying a reading
from a vi? Then press the Local button on the instrument (actually
the other feature of the Save
br
Hello,
To communicate with a CAN/DeviceNET bus you will need an interface
card in your PC. NI has such cards along with LabVIEW VIs:
http://sine.ni.com/apps/we/nioc.vp?cid=1329lang=US
http://sine.ni.com/apps/we/nioc.vp?cid=1311lang=US
To communicate with Modbus, you will NOT need any
Sorry, I meant bthreshold array.vi/b also from the array
palette. You migh need to multiply the array with (-1), depending on
the sign of the slope in the region of interest.
Michel (spelled like a French name, n'est pas):
I am not sure what you are trying to do. Perhaps an example would
make it more clear. Are you trying to jump to vi2 while inside vi1,
and then jump to vi1 while in vi2? If so, you would need buttons in
each vi to run the next vi. Or maybe you are
Re. my previous question.
I will be scanning 26 analogue channels at 7 khz into the PCI 6024E
using a SCXI 1000 with an 1100 temperature module and the voltage
signals going into the 1180 direct feedthrough.
I would like to acquire up to 3 seconds of data at 7 khz on all 26
channels. I then
Looks like Microsoft is trying to get into NI's space here.
SoftWire is a graphical programming extension for Microsoft Visual
Studio .NET
Maybe NI should got after MS and Softwire on antitrust as well. Let's
hope they all settle out of court. I'm just starting to get comfortable
with NI. I
For your ceiling value wire a DBL (or SGL) and enter Inf for the
value (without the quotes).
Tim
There is a DIGITs command that sets the resolution. After a reset, the
instrument is set for 4 digits I believe. You should be able to find
the command in the manual in the :Sense subsystem. I use
:SENS:FREQ:ARM:STOP:DIG 6 to set my counter for 6 digit resolution on
frequency measurements.
LabVIEW 7 has a calander control - drop a time stamp control on your
front panel (control palettenumerictime stamp), and then click the
button next to the control.
Thanks!
I see, the include option is for the true/false output.
I didn't think about using infinity...that's elegant enough for me.
- John
No, the LabVIEW Software was never installed on this PC before. This
is a Laptop PC, my own personal machine.
The book lists that it is in its 5th Printing with a date of October
2002.
I saw in some other threads, that this appears to be a somewhat common
problem. One of the Support Personnel
That looks like the menu for LabVIEW Full version and not
Professional. You're also missing the Compare and Source Code Controls
items. You might want to double check your license. Does your LV
install CD state Professional Development System? When you did the
install, did you choose a custom
This is an excellent suggestion. I've never been happy with making controls
invisible or hiding them off-screen. That strategy seems to violate the
whole point of data flow.
Johann Junginger.
-Original Message-
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]
Sent: Tuesday, January
Jack Hamilton [EMAIL PROTECTED] wrote:
I would like to see a dynamic controls palette that accumulates the Last
Used controls and functions. This is similar to Excels formula browser
interface which shows a list of the Last Used' functions at the top. I
would be nice to make this somewhat
Or, if you use the Queue functions a lot, just customize your palette
view to include the Queue menu on the top level of the palette.
At least you'll have less digging to do.
Ed
Edwin O. Dickens - Certified LabVIEW Developer
DISTek
I need to detect a plteau (or multiple plateaus) and output the index
of the first and last numbers of that plateau (similar to peak detect
program, except a plateau).
The issue is those little palettes clutter up the screen. I find myself
leaving the queue palette on screen, using it 2 or 3 times, then after
20 minutes I get sick of it being in the way and I close it.
Invariably, I seem need it again right after that!
Jason Dunham
SF Industrial Software,
I'm trying to run a perl script from the System Exec VI and keep getting an error code
of 2 (Out of memory). I can run the script just fine from a command prompt window. I
can start other things like Notepad from the System Exec VI without any errors. Any
ideas?
George
Dear,
I am Hajia Mariam Abacha, the widow of the late Gen. Sani Abacha, former Nigerian
Military Head of State who died mysteriously as a result of Cardiac Arrest. Since my
husband's death, my family is under restriction of movement and that notwithstanding,
we are being molested; policed and
I figured out what was wrong. I was calling perl incorrectly. Oops. It's still curious
that I got and Out of memory error. I guess LV couldn't figure out what else to call
it.
George
-Original Message-
From: Seifert, George
Sent: Tuesday, January 13, 2004 1:53 PM
To:
And the ability to get multiple functions at once! shift-click and get
the create, enqueue, dequeue, and destroy.
There's a feature in LV7.0 for the diagram (doesn't work on controls) that
you right click and you'll get the palette that the object came from. So if
you drop Enqueue from the
Under labview, i read a file which contains to columns of data
(float64) and generate two 1 dimensional array which i want to add.
I want to add these two arrays in a CIN. I have no problem to compile
the CIN DLL. But i problem to work with array in a CIN. What is the
structure which is
I would like to be able to add a point to a (overlayed multiplot)
graph using the mouse cursor to select a point. Additionally it would
be most useful to be able to select a data point in order to delete it
and/or replace witha new poistion by enterering x,y values or clicking
on the graph.
There are times when your max or labview gets corrupted
Format your PC and start installing windows/OS,and install labview
All the best
87 matches
Mail list logo