RE: State machines and passing references

2004-01-13 Thread Rolf Kalbermatter
Scott Serlin [EMAIL PROTECTED] wrote: Let me try it. I've been trying to right-click the case statement and not the while loop. This appears to be an oops on my part. Cases don't have shift registers and so doesn't the event structure. You only get tunnels and they are created automatically

I can't read VI's that were writen in version 3.1

2004-01-13 Thread Shai
I have some VI's that were writen with an old version of LabView(ver. 3.1).when I try to open them I get an error message that the file is to old. How can I convert those file's for thay can be read with version 6.1 of LabView. Thank you and have a nice day

my parallel port cannot work on win2000 and new pc

2004-01-13 Thread kw0001
I was troubled by the reading/writing from parallel port on win2000 for a long time. I had made my programs work on win2000/OLD PC, but i failed with the same programs on win2000/new PC. I tried with the method from the forum, that is, install accessHW and other method from my colleagues. Allways

Like tools palette feature

2004-01-13 Thread Eugenio Navacchia
Hi! I need to insert in a VI something like the Tools palette, that can be anabled or disabled via menu programmatically. The behavior should be the same as the Window--Show Tools palette option in LabVIEW front panel menu: the main VI continue running and performing his tasks, and when a menu

Re: executable vi files in windows!

2004-01-13 Thread Fonsi
Thanks Greg! I have labview 7 express pro, but i dont find the application builder, in the custom install i dont see it neither. Is application builder into this cd?. thanks.

Re: Serial Compatibility VI's not working in Labview 7.0

2004-01-13 Thread van_axl
The method you give us to make the serial working is fine , but when I try to build my VI with application builder and then try to run the exe it tells me that it cannot run the serial part ! so i cannot use it whith exe . Is there something to do before building the exe ?

Re: I can't read VI's that were writen in version 3.1

2004-01-13 Thread Nick Storton
Hi Shai, Details of the conversion kit can be found here:- http://digital.ni.com/public.nsf/3efedde4322fef19862567740067f3cc/429e45271cfd683786256d87006b1eef?OpenDocument Hope this helps, Nick

Re: How can I read the serial data from my mouse on com 1?

2004-01-13 Thread Matt Claessen
Hi, On NT/2000/XP, you will not be able to use the serial port, once it is assigned to a mouse. On 95/98/Me, you can do this, but you will lose the mouse for the remainder of your Windows session. Mouse output is not very useful for tests anyway. Get an (old) external modem for your first tests,

Re: Problems using LabVIEW-built dlls in LabVIEW

2004-01-13 Thread reke
Hi Ben, thanks for your answer and the interesting link. But I think I have the direct inverted problem to yours: You had the problem that a dll called from VB runs in a different memory space than LV, so you have no direct access to your LV application. But my problem is that a dll called from

RE: ScrollBar

2004-01-13 Thread Rolf Kalbermatter
Subramanian, Shankar, K [EMAIL PROTECTED] wrote: Thanks for your reply. I think I will stack them avoiding the scrollbar as I would not need all the buttons to be visible. But just curious to know, is there any way of automating scrollbar depending on the window? You don't work with the

Re: Bug in Unflatten from String (LV7)

2004-01-13 Thread Rolf Kalbermatter
[EMAIL PROTECTED] wrote: when unflatting certain binary datas with Unflatten fromString (LV7) I get an error msg window Nicht genügend Speicher zum Abschließen dieser Operation (* not enough memory to close this operation). The error-output of the vi is incorrect. Does anybody know a workaround

Re: Bug in Unflatten from String (LV7)

2004-01-13 Thread Uwe Frenz
Albert, I'll stay with English so everyone on the list can follow... You aked on Mon, 12 Jan 2004 16:04:03 +0100: when unflatting certain binary datas with Unflatten fromString (LV7) I get an error msg window Nicht genügend Speicher zum Abschließen dieser Operation (* not enough memory to

Bug in Unflatten from String (LV7)

2004-01-13 Thread Albert_Zeitlmeir
Thank you for your comments to my problem. You are right, I better should ad a versionnumber to my binary datas, to read them back with correct type defininition. But nevertheless I think, the unflatten from string vi must react resonable when it gets a corrupted flattened string. Obviously LV7

First Randomizer on internet with MONEY BACK GUARANTEE ....only $2 TO JOIN

2004-01-13 Thread Michael
First Randomizer on internet with MONEY BACK GUARANTEE only $2 TO JOIN . Visit: http://www.rockmyway.com/[EMAIL PROTECTED] I've made $152.00 in 3 days so can you, Join me now and make some serious

Re: Can I use any acquistion card with Labview?

2004-01-13 Thread isam
Now I feel the propositions are right and I get a clear idea. Thank you Nirmal Sharma, Dennis Knutson and Greg McKaskle.

Re: Spline Interpolation

2004-01-13 Thread Nok
HI... everybody,,, I'd like to answer my question. Can u believe that I play around this problem for 2 weeks. Then I design to use Matlab code in which it works. And at the end I realize that all of the problem only because of the data file that I load (I use German window which in Germany use

Re: Problems using LabVIEW-built dlls in LabVIEW

2004-01-13 Thread Ben
I am interested in your final solution! Please keep us updated. Ben

Re: Can I use any acquistion card with Labview?

2004-01-13 Thread isam
I think your propositions are right. Now, I get a clear idea of the qustion. Thank you.

Re: executable vi files in windows!

2004-01-13 Thread LarsRoe
It's integrated with LabVIEW. On the menu, go to ToolsBuild Application or Shared Library

Re: Serveral questions about Labview programming

2004-01-13 Thread Greg McKaskle
when I click it, the words (letters) on it can become bold, and when I click it again, the words (letters) on it can be changed to be not bold; There are two things to worry about here. How do you get the visual feedback you want, and how do you detect the action. Detecting the action is

Re: Problems using LabVIEW-built dlls in LabVIEW

2004-01-13 Thread Greg McKaskle
I believe that the specifics are that a DLL of the exact same version of LV doesn't need to load the runtime into the LV dev environment. A DLL built with a different version of LV will load the appropriate runtime, since that is the version that the VIs must have. So this doesn't help much

Reverse of Format Date/Time String.VI

2004-01-13 Thread Plassen Martin
I'm looking for a VI that does the reverse job of the Format Date/Time String, i.e. converts a string with a date and a time, and with an time format-string input that describes the format of the string, and gives a time stamp as output. Anybody done this one ? Martin

bad news?

2004-01-13 Thread John Howard
Here is an article from a recent Control Engineering newsletter... SoftWire's patent infringement lawsuit against NI to proceed Middleboro, MAMeasurement Computing Corp. and SoftWire Technology Inc. recently announced that the U.S. District Court in Boston granted on Nov. 5, 2003, the two firms'

Re: Change of VI Path Warning

2004-01-13 Thread Brian Powell
Utilities is spelled differently.

Re: Database Connectivity Toolset

2004-01-13 Thread Kelly Holmes
RL -- I will make a note of this to look into the next time we revise this manual. If you have feedback on any National Instruments documentation, you can send it to [EMAIL PROTECTED] Thank you, Kelly Holmes National Instruments

Re: my parallel port cannot work on win2000 and new pc

2004-01-13 Thread JoeLabView
I typically stay away from Dell PC's. I always have problems with them.. I'm surprised to read that a new PC doesn't support Win-98. Have you / can you try Win-NT 4? I can't understand why Win2K would be different with a newer PC. The OS assigns the base address of the parallel port to a

Re: Spline Interpolation

2004-01-13 Thread Greg McKaskle
So... I just change , to . and everything works fine. with spline function in Matlab and spline in Labview itself. Sorry it took so long to find the answer. For future reference, the Tools Options dialog has an option to use the localized decimal in the Front Panel page. This should make

How could I copy an image under labview and to stick it right A side of old

2004-01-13 Thread jah
copying shapes and stick them x times after knowing that one will differemment modify the color of each shape, I have Imaq Vision Builder

Re: how to hide mouse cursor for labview linux

2004-01-13 Thread Dennis Motshagen
Thank you for your replies. We have an embedded application with touch screen. The application is designed with LV5.1 and runs under WindowsNT. Currently we are porting the application to Linux. We want to hide the cursor, just like we did for WindowsNT. Is it also possible to change the cursor

Re: my parallel port cannot work on win2000 and new pc

2004-01-13 Thread Robert Cole
Some of the newer PCs (some DELLs included) have the parallel port disabled to free up some resources for other things in the system. Check in the BIOS (during boot) and ensure that the parallel port is enabled. Can you check the port with a parallel printer (or some other device)? Rob

Re: Reverse of Format Date/Time String.VI

2004-01-13 Thread Mads
Very simple; just wire the string to a scan from string function and extract the month, day, year, hours, minutes and seconds as separate numbers. Now the date/time to seconds function takes a cluster of these numbers and converts it to a timestamp so all you need is to bundle the numbers into

Re: Serial Compatibility VI's not working in Labview 7.0

2004-01-13 Thread waldemar.hersacher
If you use the serpdrv driver you must copy this file into the same folder where your exe is located. This is and was neccessary with all LV versions. Waldemar

Re: Spline Interpolation

2004-01-13 Thread Nok
Thanks for ur good solution for my OS.., Greg McKaskle

1 dimensional array in CIN

2004-01-13 Thread GilTremaOueZ
Under labview, i read a file which contains to columns of data (float64) and generate two 1 dimensional array which i want to add. I want to add these two arrays in a CIN. I have no problem to compile the CIN DLL. But i problem to work with array in a CIN. What is the structure which is correspond

Re: Newbie: Communicator and IBIC

2004-01-13 Thread theW
Hey Nick, Please check out my response to your message in the Instrument Connectivity/GPIB forum. Scott

Re: How do I detect number of transitions in my acquired data?

2004-01-13 Thread ldrummon
I tried your second suggestion, with setting threshold and then inverting the array. It worked great, thanks for the help!

Using OpenG Toolkit with base version of LV

2004-01-13 Thread Frank Benoit
Hi I tried to install the OpenG toolkit. But when i start it, it is missing the Read BMP File.vi and some other vi's from the Graphics Sound palette which is not included in the Base Version of LV 6.1. Has anyone tried to fix and use it with the base version? Frank

Express 7 Student Edition Question

2004-01-13 Thread Dan Fletcher
Hello: I'm playing around and learning LabView. I bought a copy of LabView 6i Student Edition and found that it didn't support the advanced data acquisition instruments (I wanted to used the continuous data acquisition example and it wouldn't work). Does anyone out there know if the new Labview 7

Re: Looking for Labview Examples for At-MIO-16DE-10 and AMUX-64T

2004-01-13 Thread toddd
Greetings, There are a variety of documents on our website that contain information about using the AMUX-64T with an MIO device. There are also example programs that show how to acquire readings using an MIO device with the AMUX-64T. I have linked to some of better documents below as well as

Re: Problems using LabVIEW-built dlls in LabVIEW

2004-01-13 Thread Ben
OK, After reading Greg's response and thinking a bit, I do have a (rather cumbersome) work-around. Here goes; LV does a wonderful job of keeping tarck of all those nasty little details like what VI is really being called and are buffers allocatoed correctly, etc, etc. In your case, this is

toggle between subVI's

2004-01-13 Thread Michel
Hello all, I need your help! I'm adjusting, for someone else, a program built by someone else! :-S, first let me discribe the problem: I have a Main VI with 5 subVI's in the Main menu (Main VI) a Bolean turns a Case structure False or True(5 times for the 5 subVI's), in this Case structure

Is there a Color-coding Convention for ICONs in LabView?

2004-01-13 Thread Javamancan
Some times I am puzzled with 16Million color to code my subvi's ICONs. I wonder if there is a Color-coding convention that I could use to specify the right color for my subvi's. If someone has figured out a way to do that please let me know.

Re: Bug in Unflatten from String (LV7)

2004-01-13 Thread Liz F
Hello Albertz, This definitely looks interesting. As with any potential bug, I would recommend contacting National Instruments tech support directly via email or phone (www.ni.com/ask) so that they can document and take action on the problem. Liz F

Re: Why is my GPIB interface dead after installing LabView 6.1 when upgrading from LabView 6.0.2

2004-01-13 Thread jlamping
Yes, I used MAX. The GPIB card shows up there. So does the GPIB instrument. I tried to test the interface with the communicate with device button. The query just timed out. We un-installed the GPIB card and then re-installed it. We un-installed all LV programs and then re-installed LV6.1.

Re: Tetrapolar Impedance Measurement with NI ELVIS

2004-01-13 Thread toddd
Greetings, I am not that familiar with bioimpedance and tetrapolar probes, but I do have experience with NI ELVIS. To me, it seems as if you are looking for something with two current outputs and two voltage inputs. If you have two constant current outputs to excite something (in your case

Re: Express 7 Student Edition Question

2004-01-13 Thread Ed Dickens
I believe the Student Edition of 7 is fully functional. It adds a tag in the lower left corner of the windows identifing it as the student edition. To be sure, you should call NI support and verify. Ed

Re: Open web page in Internet Explorer

2004-01-13 Thread Ed Dickens
Two things you could try. Drop a property node and set the VI Server Class to 'VI'. Then select as the property either Front Panel WindowIs Frontmost and create a false constant for the property or Front Panel WindowState and create a constant and set it to Minimized. Run this property node

Re: Is there a Color-coding Convention for ICONs in LabView?

2004-01-13 Thread altenbach
Actually, the colors for icons are quite limited, the max. is 256 colors. If you move around the color bars, watch the RGB indicator in the palette. It is quite quantized. Typically, I stay with a few simple colors. To make sure they are exact, I do the 16 color icon (middle) first, then convert

RE: ScrollBar

2004-01-13 Thread Kelly Bersch
I really like the idea of the tab indicator instead of stacking invisible controls. Great idea! I learn something new everyday. Kelly Bersch Senior Technician Anadigm Telephone:480-344-5262 Email: [EMAIL PROTECTED] http://www.Anadigm.com Anadigm - The Programmable Analog

RE: ScrollBar

2004-01-13 Thread Paul F. Sullivan
Shankar, You wrote: ... Is there a way I can open a subVI FP, at particular coordinates or something similar to that such that it always shows Start and does an automatic scrolling? And Kelly responded: It looks like you can use a property node for the VI and select the property Front Panel

Re: bad news?

2004-01-13 Thread John Howard
I should have included the link to the original article. Here it is: http://email.controleng.com/cgi-bin2/DM/y/efVG0GDREC0GXT0B6Ni0An John Howard [EMAIL PROTECTED] 01/13/04 09:00AM Here is an article from a recent Control Engineering newsletter... SoftWire's patent infringement lawsuit

Why can't I open a VI that I created on another computer?

2004-01-13 Thread Jesse Cugliotta
I created my VI on my laptop, and when I transfered and tried to open the VI file from my local PC, it keeps giving me a dialog box asking me to select the fileover and over and over again. Are there some other hidden files that are associated w/ the VI? Or is it all rolled into one?

Re: Using OpenG Toolkit with base version of LV

2004-01-13 Thread Frank Benoit
Thanx for the answer. I don't know the lib neither the stuctures of the user.lib directory. I unpacked like this: user.lib/ oglib_appcontrol-2.1-1/ oblib_array-2.0-1/... In the toolspalette there are many question marks. Now I downloaded OpenGoop. But the examples doesn't

LabVIEW Wishlist - Last Used Functions and Controls

2004-01-13 Thread Jack Hamilton
I would like to see a dynamic controls palette that accumulates the “Last Used” controls and functions. This is similar to Excels formula browser interface which shows a list of the “Last Used’ functions at the top. I would be nice to make this somewhat customizable so – I can load things into by

Re: Why can't I open a VI that I created on another computer?

2004-01-13 Thread Ed Dickens
There are no hidden VI's, but there may be some sub-vi's on your laptop that are not on your desktop. These could include any sub-vis you created on you laptop and any extra LabVIEW toolkits or drivers (NI-DAQ) that you installed on the laptop. If it's toolkit or driver VIs that are missing,

Easy text Report.VI...not so easy

2004-01-13 Thread TCjr
I'm using LV 7.0 and when I try to use the 'Easy Text Report.VI' I get this: Error -2147319779 occurred at library not registered. in font styoe.vi-set report font.vi-easy text report.vi-untitled 1. This error code is undefined. No one has provided a description for this code, or you migh have

Re: Generating BCH Codes for Forward Error Correction

2004-01-13 Thread Evan
I am not familiar with BCH, however you can call C DLLs in LabVIEW as well as Matlab. So you could compile thier C code into a DLL and call it using the Call Library Function Node. For more information on that refer to a

Re: Using OpenG Toolkit with base version of LV

2004-01-13 Thread Frank Benoit
Ok, than I will try this. Thx for the help

Re: Using OpenG Toolkit with base version of LV

2004-01-13 Thread Jim Kring
Frank, I would recommend modifying your OpenG Package Installer. Simply remove the missing VIs and output default values (null pictures). Then you can use the package installer. -Jim

Re: Problems using LabVIEW-built dlls in LabVIEW

2004-01-13 Thread reke
Thank you, Ben and Greg, for your effort. But my solution for now is not to use DLLs. I have only little time left for my project, so I can't spend any time in this problem. But to the idea with the wrapper VI: I don't believe that this would help, because even the wrapper VI will run in the same

Re: Generating BCH Codes for Forward Error Correction

2004-01-13 Thread echo1
I should have mentioned in my post that I don't have easy access to a C compliler. That's really where my problem lies. thanks, -dave

Getting data from an XY Graph curve

2004-01-13 Thread patrick54
I have a XY graph with the X data spaced every 0.2 (0.00, 0.20, 0.40, etc.). After I display the graph I use the curser to manually (by eye) find the inflection point in the curve (ex. 1.46). I would like the software to determine the inflection point on its own, but LabView only sees the array of

Re: Problems using LabVIEW-built dlls in LabVIEW

2004-01-13 Thread Ben
I understand time limits! I was not clear. I meant wrap a call libray function configure to use the VI in the DLL. My fault, please forgive. Ben

Re: Problem with HP53131A Universal Counter and GPIB

2004-01-13 Thread JoeLabView
How many digit precision do you get when running your vi? The asterisks may only appear to indicate that you are in remote mode. The precision shouldn't change. Have you tried displaying a reading from a vi? Then press the Local button on the instrument (actually the other feature of the Save

Re: Can i communicate with labview, using ethernet or seriel modbus.

2004-01-13 Thread Khalid
br Hello, To communicate with a CAN/DeviceNET bus you will need an interface card in your PC. NI has such cards along with LabVIEW VIs: http://sine.ni.com/apps/we/nioc.vp?cid=1329lang=US http://sine.ni.com/apps/we/nioc.vp?cid=1311lang=US To communicate with Modbus, you will NOT need any

Re: Getting data from an XY Graph curve

2004-01-13 Thread altenbach
Sorry, I meant bthreshold array.vi/b also from the array palette. You migh need to multiply the array with (-1), depending on the sign of the slope in the region of interest.

Re: toggle between subVI's

2004-01-13 Thread tbob
Michel (spelled like a French name, n'est pas): I am not sure what you are trying to do. Perhaps an example would make it more clear. Are you trying to jump to vi2 while inside vi1, and then jump to vi1 while in vi2? If so, you would need buttons in each vi to run the next vi. Or maybe you are

how much time do I need to process the data

2004-01-13 Thread mhtl
Re. my previous question. I will be scanning 26 analogue channels at 7 khz into the PCI 6024E using a SCXI 1000 with an 1100 temperature module and the voltage signals going into the 1180 direct feedthrough. I would like to acquire up to 3 seconds of data at 7 khz on all 26 channels. I then

RE: bad news?

2004-01-13 Thread Scott Serlin
Looks like Microsoft is trying to get into NI's space here. SoftWire is a graphical programming extension for Microsoft Visual Studio .NET Maybe NI should got after MS and Softwire on antitrust as well. Let's hope they all settle out of court. I'm just starting to get comfortable with NI. I

Re: Use of In Range and Coerce with only floor value.

2004-01-13 Thread Shan
For your ceiling value wire a DBL (or SGL) and enter Inf for the value (without the quotes). Tim

Re: Problem with HP53131A Universal Counter and GPIB

2004-01-13 Thread Dennis Knutson
There is a DIGITs command that sets the resolution. After a reset, the instrument is set for 4 digits I believe. You should be able to find the command in the manual in the :Sense subsystem. I use :SENS:FREQ:ARM:STOP:DIG 6 to set my counter for 6 digit resolution on frequency measurements.

Re: Visual Calendar

2004-01-13 Thread crelf
LabVIEW 7 has a calander control - drop a time stamp control on your front panel (control palettenumerictime stamp), and then click the button next to the control.

Re: Use of In Range and Coerce with only floor value.

2004-01-13 Thread john_c_m
Thanks! I see, the include option is for the true/false output. I didn't think about using infinity...that's elegant enough for me. - John

Re: Labview 6.1i evaluation only good for 1 day?

2004-01-13 Thread mike_chag
No, the LabVIEW Software was never installed on this PC before. This is a Laptop PC, my own personal machine. The book lists that it is in its 5th Printing with a date of October 2002. I saw in some other threads, that this appears to be a somewhat common problem. One of the Support Personnel

Re: executable vi files in windows!

2004-01-13 Thread Dennis Knutson
That looks like the menu for LabVIEW Full version and not Professional. You're also missing the Compare and Source Code Controls items. You might want to double check your license. Does your LV install CD state Professional Development System? When you did the install, did you choose a custom

RE: ScrollBar

2004-01-13 Thread Junginger, Johann
This is an excellent suggestion. I've never been happy with making controls invisible or hiding them off-screen. That strategy seems to violate the whole point of data flow. Johann Junginger. -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] Sent: Tuesday, January

Re: LabVIEW Wishlist - Last Used Functions and Controls

2004-01-13 Thread rolf . ostvik
Jack Hamilton [EMAIL PROTECTED] wrote: I would like to see a dynamic controls palette that accumulates the Last Used controls and functions. This is similar to Excels formula browser interface which shows a list of the Last Used' functions at the top. I would be nice to make this somewhat

RE: LabVIEW Wishlist - Last Used Functions and Controls

2004-01-13 Thread Ed Dickens
Or, if you use the Queue functions a lot, just customize your palette view to include the Queue menu on the top level of the palette. At least you'll have less digging to do. Ed Edwin O. Dickens - Certified LabVIEW Developer DISTek

Does anyone know how to detect plateaus in signals

2004-01-13 Thread Alpha
I need to detect a plteau (or multiple plateaus) and output the index of the first and last numbers of that plateau (similar to peak detect program, except a plateau).

RE: LabVIEW Wishlist - Last Used Functions and Controls

2004-01-13 Thread Jason Dunham
The issue is those little palettes clutter up the screen. I find myself leaving the queue palette on screen, using it 2 or 3 times, then after 20 minutes I get sick of it being in the way and I close it. Invariably, I seem need it again right after that! Jason Dunham SF Industrial Software,

Out of memory error

2004-01-13 Thread Seifert, George
I'm trying to run a perl script from the System Exec VI and keep getting an error code of 2 (Out of memory). I can run the script just fine from a command prompt window. I can start other things like Notepad from the System Exec VI without any errors. Any ideas? George

PLEASE HELP

2004-01-13 Thread HAJIA MARIAM ABACHA
Dear, I am Hajia Mariam Abacha, the widow of the late Gen. Sani Abacha, former Nigerian Military Head of State who died mysteriously as a result of Cardiac Arrest. Since my husband's death, my family is under restriction of movement and that notwithstanding, we are being molested; policed and

RE: Out of memory error

2004-01-13 Thread Seifert, George
I figured out what was wrong. I was calling perl incorrectly. Oops. It's still curious that I got and Out of memory error. I guess LV couldn't figure out what else to call it. George -Original Message- From: Seifert, George Sent: Tuesday, January 13, 2004 1:53 PM To:

Re: Last Used Functions and Controls -- have you used LV7.0?

2004-01-13 Thread stephen . mercer
And the ability to get multiple functions at once! shift-click and get the create, enqueue, dequeue, and destroy. There's a feature in LV7.0 for the diagram (doesn't work on controls) that you right click and you'll get the palette that the object came from. So if you drop Enqueue from the

Re: 1 dimensional array in CIN

2004-01-13 Thread Greg McKaskle
Under labview, i read a file which contains to columns of data (float64) and generate two 1 dimensional array which i want to add. I want to add these two arrays in a CIN. I have no problem to compile the CIN DLL. But i problem to work with array in a CIN. What is the structure which is

Re: Changing data point on Graph using a mouse to select pts

2004-01-13 Thread Greg McKaskle
I would like to be able to add a point to a (overlayed multiplot) graph using the mouse cursor to select a point. Additionally it would be most useful to be able to select a data point in order to delete it and/or replace witha new poistion by enterering x,y values or clicking on the graph.

Re: NImax.exe has generated errors. You must restart the program, a log file is being created.

2004-01-13 Thread Mathews
There are times when your max or labview gets corrupted Format your PC and start installing windows/OS,and install labview All the best