(RADIATOR) Disallow e-mail account in LDAP server to login

2003-11-13 Thread deden purnamahadi
Dear all, We have an LDAP server, used by Radiator and email account. One user will have 1 access ID and 1 or more email account.All in the same LDAP server. Anyone has a sample of configuration of Radiator to allow only access ID to login but not email account ? Warmest regards Deden _

Re: (RADIATOR) LEAP, Cisco 1200 AP, and Bad Authenticator message

2003-11-13 Thread Mike McCauley
Hello John, Ooops, we accidentally left the example leap.cfg out of the distribution. It is now available in the patches area, and attached to this email. Sorry about that. The most likely cause of the error you are seeing is that the shared secrets between Radiator and your NAS are not the sa

(RADIATOR) LEAP, Cisco 1200 AP, and Bad Authenticator message

2003-11-13 Thread John Hoarty
I have Cisco 1200 APs and Panasonic Toughbook tablet PCs which are LEAP compatible. I get the Following error in my log file: *** Received from 10.192.10.26 port 1100 Code: Access-Request Identifier: 51 Authentic: <1>$<248>7<224>>O<202><157>h<232><9><243><199><213><252> Attributes:

Re: (RADIATOR) and Rodopi 5.3 or 5.4

2003-11-13 Thread Mike McCauley
Hello Ksenia, As Rodolfo says, we would expect Radiator AuthBy RODOPI to work with all recent versions of Rodopi. Although the doc does mention Logins and UsageOnlineHours, Radiator only uses Rodopi stored procedures to access the Rodopi database. Cheers. On Fri, 14 Nov 2003 03:10 am, Rodolf

Re: (RADIATOR) Input queue size

2003-11-13 Thread Hugh Irvine
Hello Vangelis - See my other mail on this topic, but I suggest you use different log files for different Radiator instances. regards Hugh On 13/11/2003, at 7:59 PM, Vangelis Kyriakakis wrote: Can all these Radiator instances use the same logfiles? Or they'll have problems racing for file lo

Re: (RADIATOR) integer disconnect causes

2003-11-13 Thread Hugh Irvine
Hello Bogdan - This should be fixed in the latest version Radiator 3.7.1. From the history file: â Improvements to storage of VALUE in dictionary allows decoding based on the attribute name rather than the number, which allows correct unpacking of attributes with synonyms, such as Ascend-Di

Re: (RADIATOR) Input queue size

2003-11-13 Thread Hugh Irvine
Hello Matthew - You are quite correct. Radiator does an "open-write-close" for every log event. In spite of this however I would not recommend having more than one Radiator instance writing to a log file as it becomes almost impossible to then understand what is going on. It is _much_ better t

Re: (RADIATOR) 802.1x PEAP Cisco XP LDAP

2003-11-13 Thread Hugh Irvine
Hello Jaskaran - There are several example configuration files in the "goodies" directory ("eap_*.cfg"). There has also been some discussion on the mailing list, so check the archive: www.open.com.au/archives/radiator regards Hugh On 14/11/2003, at 6:12 AM, jsingh wrote: Hi  We want to s

(RADIATOR) 802.1x PEAP Cisco XP LDAP

2003-11-13 Thread jsingh
Hi  We want to setup a wireless network with 802.1x that authenticates users to our LDAP server with Radiator using PEAP. Where can I find the documentation to set this up? Thanks   Jaskaran Singh University Systems & Security Fairleigh Dickinson University Teaneck, NJ 07666  

RE: (RADIATOR) Input queue size

2003-11-13 Thread Matthew Trout
All radiator log accesses e done lock-write-unlock, IIRC, so you should be fine. I'd suggest double-checking with either the docs, the source, or Hugh before putting it on a production system :) > -Original Message- > From: Vangelis Kyriakakis [mailto:[EMAIL PROTECTED] > Sent: 13 Novembe

Re: (RADIATOR) and Rodopi 5.3 or 5.4

2003-11-13 Thread Rodolfo Torrado López
Of course Ksenia... I'm using Rodopi 5.3 and Radiator 3.6   Let me show some parts of my config file:   ### #Hadler session# ###     SessionDatabase MYDATABSEDBSource    dbi:ODBC:MYDSN  DBUsername Login  DBAuth  password    RejectEmptyPassword

(RADIATOR) and Rodopi 5.3 or 5.4

2003-11-13 Thread Ksenia Marasanova
Hallo list, Radiator documentation claims that provides authentication and accounting with Rodopi (see http://www.open.com.au/radiator/ref.html#pgfId=369765). But the tablenames "Logins" and "UsageOnlineHours" mentioned in that chapter don't exist in the Rodopi 5.3 or 5.4 database. I think t

(RADIATOR) integer disconnect causes

2003-11-13 Thread Bogdan TARU
Hi everyone, I have a problem with a Cisco AS5300 and the disconnect causes. They appear as integers (Ascend-Disconnect-Cause = 45) in the log file, and they are inserted into the database as integers as well. The radiator is started with -dictionary-file pointing to the 'generic' d

Re: (RADIATOR) Input queue size

2003-11-13 Thread Vangelis Kyriakakis
Can all these Radiator instances use the same logfiles? Or they'll have problems racing for file locks? Vangelis Frank Danielson wrote: It's really not that hard. You run a number of Radiator instances, with each one having it's own connection to the LDAP, SQL, or whatever backend. The

Re: (RADIATOR) Cisco NAS dont sent password to radiator. Why? DEBUG: Check item user-password expression 'kkk' does not match '' in request

2003-11-13 Thread Sergei Keler
YES! But it works with some other Authby (external, unix) by didnt work with Authby FILE 8-() I have evaluation version DLed a month ago. Sergei N Keler IT-Manager General DataComm [EMAIL PROTECTED] [www.gdc.ru] [tel. +7(812)325-1085 (ext. 0723)] [fax +7(812)325-1086] "Claudio Lapidus" <[EMA