My neighbor bought a used 8.5 ONAN. It had been in standby-backup mode for all
its life close to the Pacific. Other than the usual costal crud buildup he had
to cleanup he had to replace exactly that - the voltage regulator & they are
getting harder to find.
His mechanic also switched the distr
I had a similar issue with an On an off grid genny earlier this year. The
customer had a local On an tech come out and they replaced the voltage
regulator board and cleared up the issue.They also said these regulator boards
for the older gennies were getting hard to find, so just another thing f
Hello,
I got called in to debug an old off grid system with a Kohler 8.5 RES
generator. Across L1-L2 is 120vac. From both L1 & L2 to common gnd/neutral is
60v. I verified the windings are connected for 120/240 operation(in series with
center tap for G/N). These voltages are the same on the genny