[Repeater-Builder] Micor Compa Exciter/PA

2005-02-04 Thread wn1b8
I recently picked up a Micor Compa-Station exciter/PA. I know its for 132-174 MHz. and I believe it to be a 100 watt PA deck, but I can't seem to find what the duty cycle is. The PA board part number is TLD5953A1093R. It has the 14 1/2 long Micor fins across the top of the module. The

Re: [Repeater-Builder] Micor Compa Exciter/PA

2005-02-04 Thread Eric Lemmon
Scott, I believe that your PA is a TLD1683, 100 watt intermittent duty unit for the 150.8-162 MHz band. It should have the TFD6112A Exciter Filter and the TFD6102A Harmonic Filter, both of which are designed for the 150.8-174 MHz band. If you intend to operate this station in the 2m band,

Re: [Repeater-Builder] Micor Compa Exciter/PA

2005-02-04 Thread Neil McKie
According to my Micor manual, the TLD5953A PA Board is installed in the TLD1693E Contunuous Duty Power Amplifier on the 150.8 - 162 MHz frequency range. Is this what you are looking for? Neil - WA6KLA wn1b8 wrote: I recently picked up a Micor Compa-Station exciter/PA. I know