Dear colleagues,
I am helping some people from the University of Frankfurt with their
Rietveld refinements, and usually their powder patterns are measured on
their own instrument and the refinements are excellent. This time,
however, they have to work with a powder pattern that was sent to them.
Jacco,
could you kindly tell us the composition of the sample and the technique
used to collect the data ?
Lubo
On Wed, 10 Feb 2010, Jacco van de Streek wrote:
Dear colleagues,
I am helping some people from the University of Frankfurt with their
Rietveld refinements, and usually their
Lubomir Smrcok wrote:
could you kindly tell us the composition of the sample and the technique
used to collect the data ?
The technique to collect the data is unfortunately not known to me, I'd
have to ask.
The composition is not a secret: it is an organic pigment, Pigment
Yellow 110, and its
Dear All,
Could anybody help me with a question I have related to preferred
orientation?
I have collected some spectra of a sample, on a D4 using flat plate
geometry, that I suspect is showing preferred orientation effects. I was
under the impression that a way of testing for this is to re-pack
1. Is absorption indeed the most likely cause of this problem or are
there other possibilities?
2. How do we model absorption in TOPAS? Which keyword do we use and what
are reasonable values for the parameters in the expression?
1. You will find discussions of negative B-factors in the
Hallo,
I have problem to use FINDIT software: after the starting windows,
sometimes it freeze. Is there anyone that know how resolve this problem?
Thank you
Davide
Prof. Davide Levy
DSMP Università degli Studi di Torino
tel. +390116705122
fax +390112365122
skype davidelevy
Dear people interested in the Rietveld method,
you may be interested in the Reynolds Cup
2010 will see the staging of the 5th Reynolds Cup competition in
quantitative mineralogy. The biennial Reynolds Cup was started in 2000
by Dougal McCarty, Jan Środoń, and Dennis Eberl in honour of Bob
I have problem to use FINDIT software: after the starting windows,
sometimes it freeze. Is there anyone that know how resolve this problem?
FINDIT runs the PC version of the ICSD database. My personal opinion :-)
is that you should switch to the WWW version on
http://icsd.fiz-karlsruhe.de/ You
Dear Alan,
isn't it a little bit unfair to list just the Pros but skip the Cons?
We used to have a FINDIT subscription several years ago. Sadly,
our purchasing department canceled the subscription when we
got institutional access to the WWW version.
If I remember correctly, FINDIT had far more
Dear Ross,
I presume on the flat sample you measured regular theta-2theta diagrams,
then only probed those planes parallel to the sample plane. In such a
situation, you do not probe correctly the texture, and all the models
you could envisage are just giving back parameters that have been
Dear Frank,
As I wrote, I was referring to my personal opinion and the new ICSD WWW
pages on http://icsd.fiz-karlsruhe.de/ which do allow consecutive
searches, combination of results and methods of searching for similar
structures, structure-types etc.
FIZ provides both WWW and FINDIT versions
Dear Alan,
so it seems I am using an Interface version which is too old.
I guess I should urge the responsibles to update it.
Thanks for the information.
Best wishes,
Frank
Alan Hewat wrote:
Dear Frank,
As I wrote, I was referring to my personal opinion and the new ICSD WWW
pages on
Is it possible the data was collected with variable slit aperture? You
could try to convert the data to fixed slit aperture intensities and see
what happens to the B values.
Regards,
Jeff Nicolich
W.R. Grace Co. - Conn.
62 Whittemore Ave, Cambridge, MA 02140
+1-617-498-3816