Re: [QE-users] Band gaps from SCF vs NSCF calculations

2019-08-28 Thread Nicola Marzari
Several possibilities - simplest is that the SCF calculation is done with a coarse mesh, and the top of the valence and/or the bottom of the conduction are not located at points on this mesh. [BTW, they do not need to be located, either, along the path you chose to plot the band strcture]

[QE-users] Band gaps from SCF vs NSCF calculations

2019-08-28 Thread MARIA CATERINA CEVALLOS BRENES
Dear QE developers and users: I was computing the band gaps from scf calculations as the difference between HOMO and LUMO energies. Nonetheless, when I perform the bands' calculation and plot the band structure I notice this band gap is a lot less than the one I computed initially (with scf).

Re: [QE-users] Best way to batch process xsf files

2019-08-28 Thread Matic
Hi Chris, I have been using XCrySDen for years now and I find it very convenient for most cases but sometimes I would like to just render a bunch of xsf files (molecular orbitals) by orienting the cell in a way, setting an Isovalue and then writing out raster images. You can save a

Re: [QE-users] Best way to batch process xsf files

2019-08-28 Thread Felix Mayr