Re: [QE-users] Optimal pw command line for large systems and only Gamma point

2024-05-13 Thread Giuseppe Mattioli
Ciao Nicola You're right, I've mixed two different things too much with a misleading result. The first information was "use Gaussian smearing because in my experience makes scf more stable". The second was "if you use Gaussian smearing and scf_must_converge=.false., then you may reduce

Re: [QE-users] Optimal pw command line for large systems and only Gamma point

2024-05-13 Thread Nicola Marzari via users
On 13/05/2024 17:26, Giuseppe Mattioli wrote:     occupations= 'smearing'     smearing= 'cold'     degauss= 0.05 ! I know it's quite large, but necessary to stabilize the SCF at this preliminary stage (no geometry step done yet)     mixing_beta= 0.4 If you want to stabilize the scf it is

Re: [QE-users] Optimal pw command line for large systems and only Gamma point

2024-05-13 Thread Giuseppe Mattioli
Dear Antonio The actual time spent per scf cycle is about 33 minutes. This is not so bad. :-) The relevant parameters in the input file are the following: Some relevant parameters are not shown.     input_dft= 'pz'     ecutwfc= 25 Which kind of pseudopotential? You didn't set

Re: [QE-users] Optimal pw command line for large systems and only Gamma point

2024-05-13 Thread Antonio Cammarata via users
I did some tests. For 1000 Si atoms, I use 2010 bands because I need to get the band gap value; moreover, being a cluster, the surface states of the truncated bonds might close the gap, especially at the first steps of the geometry optimization, so it's better I use few empty bands. I managed

Re: [QE-users] Optimal pw command line for large systems and only Gamma point

2024-05-10 Thread Paolo Giannozzi
On 5/10/24 08:58, Antonio Cammarata via users wrote: pw.x -nk 1 -nt 1 -nb 1 -nd 768 -inp qe.in > qe.out too many processors for linear-algebra parallelization. 1000 Si atoms = 2000 bands (assuming an insulator with no spin polarization). Use a few tens of processors at most "some

Re: [QE-users] Optimal pw command line for large systems and only Gamma point

2024-05-10 Thread Giuseppe Mattioli
Dear Antonio Before struggling with parallelization setup, I see that Estimated total dynamical RAM >    1900.41 GB your calculation requires more or less up to 2TB RAM. I can't see your setup (e.g., the supercell containing your cluster) but I suggest that you ask yourself if there

[QE-users] Optimal pw command line for large systems and only Gamma point

2024-05-10 Thread Antonio Cammarata via users
Dear all, I have a silicon nanocluster with 1000 atoms with 1 1 1 k-mesh (only Gamma point). I cannot manage to run the calculation due to memory issue. I use a computational cluster with 128 core/node and 200 GB RAM per node. I am using PWSCF v.7.3. In the input I set ecutwfc= 29 and cg