TE has nothing to do with ions..it means that are fewer or smaller
particles, too small for the pure red light wavelengths of a laser to "find".
The rise in conductivity indicates than some of the particles turned into
ions as only ions contribute to a meter registering anything at all.
BUT, there are TWO sorts of ions in there Ag [+] and OH [-] the anion.
If the yellow was due to oxidized ions and the H2O2 scavenged the Oxy off
that molecule, the result *should be* an O2 gas emulsion [murky for a while
till the gas bubbles are dissolved into the water] and a newly made silver
ion adding to conductivity.
If a particle [crystal ] was nucleated by a silver oxide molecule and the
H2O2 broke up that nucleus into gas emulsion and an ion, the particle would
fragment into smaller pieces.
Crystals prefer to form around a nucleus.
In a case where it's mostly just unprotected ions and the Hydroxl anions
such as with very fresh EIS, the addition of "some" H2O2 might scavenge
the Oxy off the Anion and make a Hydrogen AND Oxygen gas emulsion [white
murky] where "more" H2O2 might also oxidize silver ions along with the
emulsion previously made [brown murky]
Hot water will hold less dissolved gas than cold and more kinetic energy
should cause microscopic bubbles to merge, become big enough to be buoyant
and bubble off.
Question: Does bringing EIS made murky by H2O2 clear up to *not murky*
after being heated up....to colorless or brownish ? [depending on what
color it was ]
"Stabilized" EIS could be a result of Silver Ions loosely bonding with
the Oxygen atoms of water molecules over a period of time, hence protecting
them from the action of H2O2, leaving it to prefer reactions with whatever
Silver Oxides there may be and OH anions.
Yellow clears up, indicating it was due to suspended oxide
particles...and/or...particles of that size made on those Oxide particles.
An Oxide nucleated particle could display a color yellow from both pigment
and Rayleigh Light Scattering effect...or other colors just from light
scattering overwhelming the pigmentation to just add a darker hue to the
dominating color.
Given that H2O2 removes color from yellow, violet AND red EIS, that
indicates that both particle sizes are being reduced and the destruction of
Silver Oxide nuclei is happening to cause that reduction.
If a meter is registering on OH [-] Anions after the Silver Ions have
Hydrated with the water, that could explain why conductivity drops as the
EIS stabilizes without developing a much denser TE.
But if many of the silver ions find an anion before the ions hydrate, the
conductivity would also drop with the formation of Silver Hydroxide along
with the formation of a more dense TE.
In both cases, the meter would triggering on Anions as Ions go hide.
Anions are made in a 1 to 1 ratio with ions, so using a meter to get PPM of
"Silver" is like counting apples to see how many oranges there are in a
basket of pears.
It sorta works as they are all about the same size, but you aren't doing
anything like what you'd think you are.
Tracking PH changes should clear up some details. [I find details to be
really boring]
OH [-] rich water is the definition of Alkaline Water.
BTW Most water ionizers use salt or tap water minerals, making the
Alkaline effect due to the formation of Lye or other highly water soluble
metal Hydroxide, where-as *Silver Hydroxide* is not very soluble in water.
It would be a lot cheaper and easier to just drop a few Draino Crystals in
water and drink that.
On the Acid side of the ionizer, you'd have Hypochlorous Acid rather than
H3 Hydronium rich water you would get using pure water in the Ionizer, both
useful disinfectants and both Acidic, but not quite the same thing.
If you happen to have a brand new water ionizer, try using pure water and
silver electrodes..and see what you get.
Should be pure Silver Ions in water on one side [no flavor and reacts
violently with H2O2] and pure Hydronium water on the other. [bitter flavor
and no apparent reaction with H2O2]
..a whole 'nother can o worms, ey?
Soooo... what happens if you use Silver electrodes and EIS as the conductor
with a Zapper, rather than Copper that won't ionize as at low a voltage as
Silver will and salt water as the conductive interface liquid ?
Silver Iontoporosis? ..and Hypochlorous Acid and Lye made IN the blood out
of the salt in the blood, rather than both in the blood and on the skin.
And when those two meet making themselves back into salt, left over
Silver Ions in the blood?
Would salt rather be salt over Silver Chloride? I think so.
What then?
It would appear that Silver Ions stimulate the production of stem cells as
well as sterilizing whatever they are in, virtually eliminating scar tissue
and infections while wounded pieces and parts are healing.... FAST.
A Zapper run in such a manner could use the Alkaline effect of killing
cancer cells, the PH Neutralizing / near instant detoxifying chemo dosing
control AND germicide effect of Hypochlorous Acid, AND the stem cell
stimulating effect of Silver Ions guiding cell growth patterns along with
THEIR germ fighting properties...all TARGETED depending on how electrodes
are placed, with absolute control over how much/how fast at the twist of a
variable resistor dial.
KISS [Keep it simple, Stupid ]
If you can stick a thin needle right into the middle of a brain to
stimulate that part of the brain with an electrical pulse???.. you can
insert that sucker anywhere.
A Platinum, Titanium [or even Copper] with Silver tipped needle ????? Both
depth and position location control XYZ axis style.
Kill it with Lye, Neutralize the Lye back into salt...... heal it back
perfectly with Silver.
That's one commando on the inside and the enemy surrounded by troops and
the Stem Engineers relief forces on hand to fill in the craters and
reconstruct the town.
Gee, that's a H of a LOT of ELPING ANDS using nothing more than a little
silver, a discomfort calibrated dial and a Triple A battery.
Robert Becker didn't go far enough.....it's "The Body Electrochemical" be
it by magnetic inductance or a more controllable direct connection.
ode
At 02:43 PM 4/13/2010 +0100, you wrote:
It was sitting for 48 hours sol when I noticed it had gone yellow (the 2nd
batch) I put in one drop of H202 and thats when it went cloudy. It
cleared after adding another drop though, and the ppm went up from 8 to
10ppm. I've noticed that after another day sitting, that the tyndall is
now weaker. Is this because there are less ions now do you think? dee
--
The Silver List is a moderated forum for discussing Colloidal Silver.
Rules and Instructions: http://www.silverlist.org
Unsubscribe:
<mailto:[email protected]?subject=unsubscribe>
Archives:
http://www.mail-archive.com/[email protected]/maillist.html
Off-Topic discussions: <mailto:[email protected]>
List Owner: Mike Devour <mailto:[email protected]>