Hi,

There must be a bug in the version of sipXtapi that you're using.  Try
downloading previous versions of sipXtapi and see if you can unititialize
and remove lines successfully.

Regards,
Joseph

On 12/16/06, zamie zamie <[EMAIL PROTECTED]> wrote:

Hi,
Yes. I've tried to register both 301 and 302 separately. Both works fine.
Problem occurs when I started my softphone with 301 and when I tried to
change the setting to 302, nothing happened. As for now, if I want to change
my softphone from the current setting to a new one, I've to stop and re-run
my program.

I dont have any specific ideas on what are the causes since few ppl here
mentioned that changing the credentials without having to stop and re-run
the program should be not a problem.

The functions in sipxtapi that I'm using right now is sipxinitialize and
sipxuninitilize. Tried to use sipxreinitilize but it produces error.

Details:
Sip Server : Asterisk
Softphone : Self-developed softphone deploying sipxtapi.dll
Platform    : Windows
Programming Language : Visual C++

Please advise

Regards,
Zamielia

----- Original Message ----
From: Joseph Serafin Aguilar <[EMAIL PROTECTED]>
To: Scott Lawrence <[EMAIL PROTECTED]>
Cc: zamie zamie <[EMAIL PROTECTED]>; [email protected]
Sent: Saturday, December 16, 2006 4:22:46 AM
Subject: Re: [sipxtapi-dev] Logout function in SipXtapi

Hi,

Have you tried registering to 302 alone? Try registering to 302 alone
first. If this doesn't work, then probably the credentials for 302 haven't
been set up yet.

Regards,
Joseph

On 12/16/06, Scott Lawrence <[EMAIL PROTECTED]> wrote:
>
> On Thu, 2006-12-14 at 17:50 -0800, zamie zamie wrote:
> > I used the same method that I used to register 301 for 302.
> >
> > Being registered for 301 should have no effect on registering for 302.
> > -> If by any chance the 301 setting is not completely unregister, can
> > 302 be registered on the same softphone? As, after executing
> > uninitialize process, and trying to register new sip setting, i keep
> > on getting 401 error. I've check the settings (realm, password etc),
> > all are correct.
>
> There is no problem (using sipXpbx) with having the same phone register
> any number of identities.
>
>
> --
> Scott Lawrence  tel:+1-781-938-5306;ext=162 or sip:[EMAIL PROTECTED]
>   sipXpbx project coordinator - SIPfoundry
> http://www.sipfoundry.org/sipX
>   Chief Technology Officer    - Pingtel Corp. http://www.pingtel.com/
>
> _______________________________________________
> sipxtapi-dev mailing list
> [email protected]
> List Archive: http://list.sipfoundry.org/archive/sipxtapi-dev/
>



__________________________________________________
Do You Yahoo!?
Tired of spam? Yahoo! Mail has the best spam protection around
http://mail.yahoo.com

_______________________________________________