On 08/31/2010 01:24 PM, Bhupesh SHARMA wrote: > Hi Mark, > >> -----Original Message----- >> From: Marc Kleine-Budde [mailto:[email protected]] >> Sent: Tuesday, August 31, 2010 4:36 PM >> To: Bhupesh SHARMA >> Cc: Wolfgang Grandegger; [email protected] >> Subject: Re: [RFC PATCH 2/4 RESEND] Bosch CCAN driver >> >> Bhupesh SHARMA wrote: >>> >>>> -----Original Message----- >>>> From: Marc Kleine-Budde [mailto:[email protected]] >>>> Sent: Tuesday, August 31, 2010 4:12 PM >>>> To: Bhupesh SHARMA >>>> Cc: Wolfgang Grandegger; [email protected] >>>> Subject: Re: [RFC PATCH 2/4 RESEND] Bosch CCAN driver >>>> >>>> Bhupesh SHARMA wrote: >>>> >>>> [...] >>>> >>>>>>> +enum bosch_ccan_operating_mode { >>>>>>> + CCAN_NORMAL_MODE = 0, >>>>>>> + CCAN_BASIC_MODE, >>>>>>> + CCAN_LOOPBACK_MODE, >>>>>>> + CCAN_LOOPBACK_WITH_SILENT_MODE, >>>>>>> + CCAN_SILENT_MODE >>>>>>> +}; >>>>>> I do not see a need for another enumeration o the type. We already >>>>>> have the CAN_CTRLMODE_*. >>>>> Yes. But I don't see CAN_CTRLMODE_* capturing all the operating >> mode >>>> types supported by Bosch CCAN. >>>> >>>> which are missing? >>> >>> I guess CCAN_BASIC_MODE and CCAN_LOOPBACK_WITH_SILENT_MODE are >> missing. >>> Or am I missing something here. >> >> ccan's silent seems to map to socketcan's listen only. >> >> What's the difference between normal and basic mode? > > Correct, ccan's silent maps to socketcan's listen but what about 'loopback > with silent' mode supported by ccan.
(CAN_CTRLMODE_LOOPBACK | CAN_CTRLMODE_LISTENONLY) ? > Also the normal and basic modes differ. As per the Bosch CCAN User Manual: > Basic Mode: > The IF1 Registers are used as Transmit Buffer and the IF2 Registers are used > as Receive Buffer. > The transmission of the contents of the IF1 Registers is requested by writing > the Busy bit of the IF1 Command > Request Register to '1' and after the reception of a message the contents of > the shift register is stored into > the IF2 Registers, without any acceptance filtering. > > In Basic Mode the evaluation of all Message Object related control and status > bits and of the > control bits of the IFx Command Mask Registers is turned off. > > This is entirely different from the NORMAL mode. But you do not use the basic mode and it makes little sense to support it. Wolfgang. > > Regards, > Bhupesh > > _______________________________________________ > Socketcan-core mailing list > [email protected] > https://lists.berlios.de/mailman/listinfo/socketcan-core > > _______________________________________________ Socketcan-core mailing list [email protected] https://lists.berlios.de/mailman/listinfo/socketcan-core