On Thu, Jan 06, 2000 at 09:56:56AM -0800, David S. Miller wrote:
>    Date: Thu, 6 Jan 2000 12:39:08 -0500
>    From: Ben Collins <[EMAIL PROTECTED]>
> 
>    This is actually against the CVS. Basically what is there now only allows
>    for the SYM53C8XX driver to be configured. This patch is taken directly
>    from drivers/scsi/Config.in and allows for both or either one to be
>    configured (notably, the current way wouldn't allow my U30 to boot using
>    the SYM53C8XX driver).
> 
>    2.3.36 seems to have the same problem.
> 
> Using only the SYM53C8XX driver is on purpose.  The NCR53C8XX driver
> causes severe problems on newer AXi systems.
> 
> Can you explain why your Ultra30 does not work with the SYM53C8XX
> driver?  I'd like to fix that seperately.

It did not detect the scsi device. However, using the NCR driver works
fine, and to test it, all I did was s/SYM53C8XX/NCR53C8XX/ in the .config,
then compile.

-- 
 -----------=======-=-======-=========-----------=====------------=-=------