David, the 82335 drivers came with the complete SW package that I sent you. I don't know if the drivers and SW are running with any more recent or non MS versions than MS-DOS 6.0. But, it's as easy to find out as it gets. Back in the day the whole OS fitted on a floppy disk and 640k of memory, together with a 33 MHz 486 did the job.
Btw. a modern 2,000 MHz or something clocked PC with 4,000,000k of memory doesn't seem to work any faster... And, no, even if you get MS-DOS installed on it, you're not gonna have much fun. Adrian davidh schrieb: > > > Folks, > > I'm also working on getting the MSDOS version running. What is the > most recent version of DOS that people have found to work with the A > 01.01 version. > > Also, can anyone advise where the command drivers for the 82335 can be > found? > > Cheers, > > david > >> Hi Adrian, >> >> Got the spec lines working now, thanks! >> >> Yes, the DOS version. I was hoping for an updated user manual for >> that version as the manual describes the other software version, and >> maybe a slightly later sw version. Oh well. >> >> Thanks for you help! >> Said >> >> >> >> On Feb 17, 2012, at 5:06, Adrian >> <rfnuts-kvp5wt2u...@public.gmane.org> wrote: >> >>> Said, >>> >>> are you using the Opt. 311 (MS-DOS) software? >>> I don't know of any more recent versions. >>> >>> To answer your initial question: >>> You can not change anything on the diagram _after_ the measurement, >>> not even the title. >>> The spec lines will be visible only when you have defined them prior >>> to starting the measurement. >>> >>> Regards, >>> Adrian >>> >>> >>> saidjack-ydxpq3io...@public.gmane.org schrieb: >>>> Hello team, >>>> >>>> I am trying to get an HP 3048A system up and running, and I am having >>>> problems with enabling spec limit lines on the graph. >>>> >>>> I can enter the spec line data under the "manipulate results" then >>>> "spec >>>> lines" menu, but the lines I entered are not visible. There are the >>>> standard >>>> spec lines visible when I do the internal noise floor test, so I >>>> know this >>>> should work. >>>> >>>> Does anyone know how to enable these properly? The user manual >>>> doesn't talk >>>> about this, and it is written for an older version of the software >>>> anyway's. >>>> >>>> Also, I have software version A 01.01 from 1994, does anyone have >>>> any more >>>> recent software version? >>>> >>>> Thanks in advance, >>>> Said >>>> _______________________________________________ >>>> time-nuts mailing list -- time-nuts-jsktletq...@public.gmane.org >>>> To unsubscribe, go to >>>> https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts >>>> and follow the instructions there. >>>> >>> >>> >>> _______________________________________________ >>> time-nuts mailing list -- time-nuts-jsktletq...@public.gmane.org >>> To unsubscribe, go to >>> https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts >>> and follow the instructions there. >> > > > _______________________________________________ > time-nuts mailing list -- time-nuts@febo.com > To unsubscribe, go to > https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts > and follow the instructions there. > _______________________________________________ time-nuts mailing list -- time-nuts@febo.com To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.