Hi

> On Apr 26, 2017, at 12:29 AM, Jerry Hancock <je...@hanler.com> wrote:
> 
> Do typical  frequency counters start their gate in phase with the incoming 
> signal?  I guess the 
> answer would be, "It depends."  I was just thinking about how I would program 
> the STM32F7 
> counter I am designing.

Since they don’t start (or stop) the gate in any specific relation to the input 
signal, the trick is to
make sure you don’t get an extra count when the gate opens or closes. This is 
right back to the
edge triggered vs level triggered issue. It also gets indirectly into the 
rechecking process in the
MCU. Some of the “edge trigger” stuff is done in odd ways ….(= got two of the 
same after rechecking
into a shift register …).

Bob


> 
> btw, Gilbert, a local time-nut, sold me a 5335 today so I will be able to 
> buiild one great one 
> out of the two I will have.
> 
> Jerry
> _______________________________________________
> time-nuts mailing list -- time-nuts@febo.com
> To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
> and follow the instructions there.

_______________________________________________
time-nuts mailing list -- time-nuts@febo.com
To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
and follow the instructions there.