How many cpe's on the ap?

Are you saying you tried 5.6.2 to 5.6.9 and a couple of betas on the AP?

Is the AP an XM version?

What firmware versions are on the CPE?

Don't suppose there is a ping watchdog on the AP.

On Tue, December 27, 2016 10:42 pm, Rory Conaway wrote:
> We tried 3 different PB400 nose cones, a NB19, and different versions of
> firmware from 5.6.2 to 5.6.9 and a couple of beta versions including v6.0
> beta 15 and as soon as the client connects to the AP, the PB400's and
> NB19's reboot.  We have used different cables, power supplies, etc...
> Putting on 6.0 right now but this is just weird.  We have also tried
> multiple IP addresses in case there was an IP conflict.   Any ideas are
> welcome.
>
> Rory Conaway * Triad Wireless * CEO
> 4226 S. 37th Street * Phoenix * AZ 85040
> 602-426-0542
> r...@triadwireless.net<mailto:r...@triadwireless.net>
> www.triadwireless.net<http://www.triadwireless.net/>
>
>
> "I led the league in go get 'em next time." - Bob
> Uecker<http://www.baseball-almanac.com/players/player.php?p=ueckebo01>
>
>
> _______________________________________________
> Ubnt_users mailing list
> Ubnt_users@wispa.org
> http://lists.wispa.org/mailman/listinfo/ubnt_users
>
>


_______________________________________________
Ubnt_users mailing list
Ubnt_users@wispa.org
http://lists.wispa.org/mailman/listinfo/ubnt_users

Reply via email to