Hi Biplop,

CEP library internally must ensure order of the incoming events. It sorts
events upon Watermark arrival. At that time it sorts events with timestamp
< Watermark.

With BoundedOutOfOrdernessTimestampExtractor a Watermark with time* t* is
generated if there arrives event with timestamp *t + maxOutOfOrderness*.

Try adding event like: 12,b,70000,6 to your test set and some alerts should
be generated.

Z pozdrowieniami! / Cheers!

Dawid Wysakowicz

*Data/Software Engineer*

Skype: dawid_wys | Twitter: @OneMoreCoder

<http://getindata.com/>

2017-06-06 15:17 GMT+02:00 Biplob Biswas <revolutioni...@gmail.com>:

> Sorry to bombard with so many messages , but one last thing is the example
> would produce alert if the line specifying Event Time is commented out.
>
> More specifically, this one:
>
> env.setStreamTimeCharacteristic(TimeCharacteristic.EventTime);
>
>
> Only with event time, there is no alert.
>
> Thanks, Biplob
>
>
>
> --
> View this message in context: http://apache-flink-user-
> mailing-list-archive.2336050.n4.nabble.com/Queries-regarding-FlinkCEP-
> tp13454p13513.html
> Sent from the Apache Flink User Mailing List archive. mailing list archive
> at Nabble.com.
>

Reply via email to