Hi

restart the job it's ok and i do that , but i must cancel the job and
submit a new one and i dont want the data from the state
forget to  mention that i use the parameter "-allowNonRestoredState"


my steps:
1. stop the job with savepoint
2. run the updated job ( update job graph) from savepoint

expect it to run

currently the result is the the job fail

nick



‫בתאריך יום ב׳, 4 בדצמ׳ 2023 ב-8:41 מאת ‪Xuyang‬‏ <‪xyzhong...@163.com‬‏>:‬

> Hi, nick.
>
> > using savepoint i must cancel the job to be able run the new graph
>
> Do you mean that you need cancel and start the job using the new flink job
> graph in 1.17.1,
> and in the past, it was able to make the changes to the new operator
> effective without restarting the job?
>
> I think in order for the new job graph to take effect, it is necessary to
> restart the job.
>
> --
>     Best!
>     Xuyang
>
>
> At 2023-12-03 21:49:23, "nick toker" <nick.toker....@gmail.com> wrote:
>
> Hi
>
> when i add or remove an operator in the job graph , using savepoint i must
> cancel the job to be able run the new graph
>
> e.g. by adding or removing operator (like new sink target)
> it was working in the past
> i using flink 1.17.1
>
> 1. is it a known bug? if so when planned to be fix
>
> 2. do i need to do something to make it work?
>
>
> nick
>
>