Hi restart the job it's ok and i do that , but i must cancel the job and submit a new one and i dont want the data from the state forget to mention that i use the parameter "-allowNonRestoredState"
my steps: 1. stop the job with savepoint 2. run the updated job ( update job graph) from savepoint expect it to run currently the result is the the job fail nick בתאריך יום ב׳, 4 בדצמ׳ 2023 ב-8:41 מאת Xuyang <xyzhong...@163.com>: > Hi, nick. > > > using savepoint i must cancel the job to be able run the new graph > > Do you mean that you need cancel and start the job using the new flink job > graph in 1.17.1, > and in the past, it was able to make the changes to the new operator > effective without restarting the job? > > I think in order for the new job graph to take effect, it is necessary to > restart the job. > > -- > Best! > Xuyang > > > At 2023-12-03 21:49:23, "nick toker" <nick.toker....@gmail.com> wrote: > > Hi > > when i add or remove an operator in the job graph , using savepoint i must > cancel the job to be able run the new graph > > e.g. by adding or removing operator (like new sink target) > it was working in the past > i using flink 1.17.1 > > 1. is it a known bug? if so when planned to be fix > > 2. do i need to do something to make it work? > > > nick > >