On Saturday, 27 April 2019 15:58:57 UTC+2, Leon Shaner wrote:
>
> Hey, Ken,
>
> You've got two [Interceptor] sections, run together, using two different 
> IP addresses.
>
> So you should end up with the following for the [Interceptor] section, but 
> check that the IP is correct:
>
>
> ##############################################################################
>
> [Interceptor]
>     # This section is for the network traffic interceptor driver.
>
>     # The driver to use:
>     driver = user.interceptor
>
>     # Specify the hardware device to capture.  Options include:
>     #   acurite-bridge - acurite internet bridge, smarthub, or access
>     #   observer - fine offset WH2600/HP1000/HP1003, ambient WS2902
>     #   lw30x - oregon scientific LW301/LW302
>     #   lacrosse-bridge - lacrosse GW1000U/C84612 internet bridge
>     #   wu-client - any hardware that uses the weather underground protocol
>
>     driver = user.interceptor
>     device_type = acurite-bridge
>     mode = listen
>     iface = ens3
>     pcap_filter = src 192.168.2.10 and dst port 80
>
>     [[sensor_map]]
>         inTemp = temperature.8565.*  
>         inTemp = temperature.12520.* 
>         inTemp = temperature.2190.*  
>
>
> ##############################################################################
>
>
> Regards,
> Leon
> --
> Leon Shaner :: Dearborn, Michigan (iPhone)
>

Thanks Leon,

However, it didn't like that:
Apr 27 15:39:52 hostname weewx[20326]: engine: Error while parsing 
configuration file /etc/weewx/weewx.conf
Apr 27 15:39:52 hostname weewx[20326]: ****    Reason: 'Duplicate keyword 
name at line 79.'

Now I've got:
[Interceptor]
    driver = user.interceptor
    device_type = acurite-bridge
    mode = listen
    iface = ens3
    pcap_filter = src 192.168.180.0/22 and dst port 80
    [[sensor_map]]
        inTemp = temperature.*.*
        inHumidity = inHumidity.*.*
        barometer = barometer.*.*
        rxCheckPercent = rxCheckPercent.*.*
        txBatteryStatus = txBatteryStatus.*.*

        #inTemp = temperature.12387.* china room 1
        #inTemp = temperature.15283.* china room 2
        #inTemp = temperature.5422.* china room 3
        #inTemp = temperature.2266.* china room 4
        #inTemp = temperature.8565.* swiss room 1
        #inTemp = temperature.12520.* swiss room 2
        #inTemp = temperature.2190.* swiss room 3

But, looking at the my webpage, I'm only getting one value for inside 
temperature, so I'm guessing that I need to define each sensor with a 
different name other than inTemp

-- 
You received this message because you are subscribed to the Google Groups 
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to weewx-user+unsubscr...@googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

Reply via email to