On Saturday, 27 April 2019 15:58:57 UTC+2, Leon Shaner wrote: > > Hey, Ken, > > You've got two [Interceptor] sections, run together, using two different > IP addresses. > > So you should end up with the following for the [Interceptor] section, but > check that the IP is correct: > > > ############################################################################## > > [Interceptor] > # This section is for the network traffic interceptor driver. > > # The driver to use: > driver = user.interceptor > > # Specify the hardware device to capture. Options include: > # acurite-bridge - acurite internet bridge, smarthub, or access > # observer - fine offset WH2600/HP1000/HP1003, ambient WS2902 > # lw30x - oregon scientific LW301/LW302 > # lacrosse-bridge - lacrosse GW1000U/C84612 internet bridge > # wu-client - any hardware that uses the weather underground protocol > > driver = user.interceptor > device_type = acurite-bridge > mode = listen > iface = ens3 > pcap_filter = src 192.168.2.10 and dst port 80 > > [[sensor_map]] > inTemp = temperature.8565.* > inTemp = temperature.12520.* > inTemp = temperature.2190.* > > > ############################################################################## > > > Regards, > Leon > -- > Leon Shaner :: Dearborn, Michigan (iPhone) >
Thanks Leon, However, it didn't like that: Apr 27 15:39:52 hostname weewx[20326]: engine: Error while parsing configuration file /etc/weewx/weewx.conf Apr 27 15:39:52 hostname weewx[20326]: **** Reason: 'Duplicate keyword name at line 79.' Now I've got: [Interceptor] driver = user.interceptor device_type = acurite-bridge mode = listen iface = ens3 pcap_filter = src 192.168.180.0/22 and dst port 80 [[sensor_map]] inTemp = temperature.*.* inHumidity = inHumidity.*.* barometer = barometer.*.* rxCheckPercent = rxCheckPercent.*.* txBatteryStatus = txBatteryStatus.*.* #inTemp = temperature.12387.* china room 1 #inTemp = temperature.15283.* china room 2 #inTemp = temperature.5422.* china room 3 #inTemp = temperature.2266.* china room 4 #inTemp = temperature.8565.* swiss room 1 #inTemp = temperature.12520.* swiss room 2 #inTemp = temperature.2190.* swiss room 3 But, looking at the my webpage, I'm only getting one value for inside temperature, so I'm guessing that I need to define each sensor with a different name other than inTemp -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it, send an email to weewx-user+unsubscr...@googlegroups.com. For more options, visit https://groups.google.com/d/optout.