The service StdWXCalculate sets where wind chill (and other derived types) comes from. If you set it to "prefer_hardware", it should come from the VP2, if it's available.
Also, please note that wind chill does not kick in unless the wind is over 3 mph, and the temperature is below 50F. The online documentation is for V4.1, but the semantics are the same for your version. See the section [[Calculations]] <http://www.weewx.com/docs/usersguide.htm#[[Calculations]]>. On Fri, Jul 24, 2020 at 11:03 AM brisguy foo <iamst...@gmail.com> wrote: > Hello all, > > I have been using weewx (3.9.2.1 with standard skin) successfully for > several months now and just noticed that the wind chill graph does not > reflect the values reported by my VP2. It always matches the outside temp > values. I have seen that weewx can calculate wind chill on its own, but > since the VP2 provides this data, I was expecting weewx to use it. Does it? > > Thanks > > -- > You received this message because you are subscribed to the Google Groups > "weewx-user" group. > To unsubscribe from this group and stop receiving emails from it, send an > email to weewx-user+unsubscr...@googlegroups.com. > To view this discussion on the web visit > https://groups.google.com/d/msgid/weewx-user/d3d9484a-e40d-457b-a2c3-42f891605a57o%40googlegroups.com > <https://groups.google.com/d/msgid/weewx-user/d3d9484a-e40d-457b-a2c3-42f891605a57o%40googlegroups.com?utm_medium=email&utm_source=footer> > . > -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it, send an email to weewx-user+unsubscr...@googlegroups.com. To view this discussion on the web visit https://groups.google.com/d/msgid/weewx-user/CAPq0zEDq1yfDfr83HUANs_PA-cAoY%2BTt5Ln8cohZb1AyiOLMWA%40mail.gmail.com.