"May I suggest that WSJT-X should be desensitized from these transient OmniRig fault reports by only responding if they persist for x seconds. "
I made a temporary change to my controller code to flag TS-590 data fail if either IF, or FA, or FB is not received for 500 ms. This configuration detected data loss for the OmniRig dialog closure event. The data seems to indicate that data was lost for about 500.3 ms (500+(25.910-25.626)). I cannot see why WSJT-X should fail for a data loss that short. 0:00:05.085 displaying L/C Set screen 0:00:25.626 Ken data not fresh 0:00:25.684 displaying Active Warnings screen 0:00:25.718 Kenwood Data Fail 0:00:25.719 Ken data not fresh 0:00:25.720 Ken data not fresh . . 0:00:25.815 Ken data not fresh 0:00:25.818 Ken data not fresh 0:00:25.821 New IF - IF00010136000 003700005020010000; 0:00:25.827 Ken data not fresh 0:00:25.829 Ken data not fresh 0:00:25.833 Ken data not fresh 0:00:25.835 Ken data not fresh 0:00:25.837 Ken data not fresh 0:00:25.840 Ken data not fresh 0:00:25.843 Ken data not fresh 0:00:25.847 Ken data not fresh 0:00:25.849 Ken data not fresh 0:00:25.852 Ken data not fresh 0:00:25.854 Ken data not fresh 0:00:25.858 Ken data not fresh 0:00:25.861 Ken data not fresh 0:00:25.865 Ken data not fresh 0:00:25.867 New FA - FA00010136000; 0:00:25.871 Ken data not fresh 0:00:25.873 Ken data not fresh 0:00:25.875 Ken data not fresh 0:00:25.878 Ken data not fresh 0:00:25.881 Ken data not fresh 0:00:25.884 Ken data not fresh 0:00:25.887 Ken data not fresh 0:00:25.890 Ken data not fresh 0:00:25.892 Ken data not fresh 0:00:25.896 Ken data not fresh 0:00:25.899 Ken data not fresh 0:00:25.903 Ken data not fresh 0:00:25.905 Ken data not fresh 0:00:25.908 Ken data not fresh 0:00:25.910 New FB - FB00010137000; 0:00:25.915 warning cleared 73, Andy, k3wyc
_______________________________________________ wsjt-devel mailing list wsjt-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/wsjt-devel