Well I think I have the answer to my question.  The backlight on my controller 
times out after 15 minutes of no activity on the user interface and no changes 
in TS-590 data.  I was alerted to an anomaly when the back light unexpectedly 
turned on.  The data appears to show that WSJT-X made 2 frequency changes, 
presumably with  the intention of testing the rig interface:


2019-07-17 16:54:17 104:19:42.598  backlight off
2019-07-17 17:05:11 104:30:31.127  New IF - IF00018100055      
004100005020010000;
2019-07-17 17:05:11 104:30:31.131  backlight on
2019-07-17 17:05:11 104:30:31.138  New FA - FA00018100055;
2019-07-17 17:05:11 104:30:31.141  New RX freq=18100055
2019-07-17 17:05:11 104:30:31.142  split offset = 945
2019-07-17 17:05:11 104:30:31.447  New IF - IF00018100000      
004100005020010000;
2019-07-17 17:05:11 104:30:31.457  New FA - FA00018100000;
2019-07-17 17:05:11 104:30:31.459  New RX freq=18100000
2019-07-17 17:05:11 104:30:31.460  split offset = 1000

I would guess that this unnecessary test sometimes fails.

I am competent to monitor my rig's frequencies and take full responsibility if 
they are not what I intended.  Please give me the option to inhibit this check.

73,
Andy, k3wyc