Hi Mark--

  Thanks for the good word.

Charles

On Sun, 03 Dec 2023 12:26:56 -0500,
Kelly, Mark wrote:
> 
> Hi Charles,
> 
> thats seems to do the trick - it is working now.
> 
> Thanks for all your help with this.
> 
> Best,
> 
> Mark
> 
> 
> 
> > On Dec 2, 2023, at 9:15 AM, Charles Schwieters <[email protected]> 
> > wrote:
> > 
> > 
> > Hi Mark--
> > 
> >> 
> >> I tried both approaches (1) wrefine_Zn.py & (2) wrefine_Zn_cs.py
> >> (below), but both give what might be the same error (with the errors
> >> at the bottom) 
> > 
> >> %CODBON-ERR: missing bond parameters %%%%%%%%%%%%%%%%%%%%%%%%%%
> >>  bond energy constant missing.
> >>  target bond length missing.
> >>  ATOM1: SEGId="    ",  RESId="401 ",  NAME="ZN+2",  CHEMical="ZN+2"
> >>  ATOM2: SEGId="    ",  RESId="6   ",  NAME="SG  ",  CHEMical="SH1E"
> > 
> > Sorry- the zinc finger parameter file works with the default Xplor-NIH
> > parameters. For water refinement, different chemical types are
> > required. Please take the attached file and place it in your
> > calculation directory.
> > 
> > <zn-finger-allhdg5.3.par>
> > Then, replace the line
> > 
> > protocol.initParams('extra/zn-finger.par')
> > 
> > with
> > 
> > protocol.initParams('zn-finger-allhdg5.3.par')
> > 
> > I have not tested this- please let me know of you have difficulties.
> > 
> > Charles
> 

########################################################################

To unsubscribe from the XPLOR-NIH list, click the following link:
http://list.nih.gov/cgi-bin/wa.exe?SUBED1=XPLOR-NIH&A=1