We have migrated from v6.x to v7.7 and v7.8 now. OSPF seems to work fine 
interacting between the two versions, just have to copy over some settings 
appropriately is all.



From: AF <af-boun...@af.afmug.com> On Behalf Of Mark - Myakka Technologies
Sent: Thursday, April 20, 2023 9:03 AM
To: AnimalFarm Microwave Users Group <af@af.afmug.com>
Subject: Re: [AFMUG] BGP Question


Josh,



I will.  I think v7 will be able to handle BGP, OSPF and Filter rules just 
fine.  Learning the new configure of v7 should not be a huge issue.  The big 
thing I'm worried about is the OSPF interaction between the versions.



--

Best regards,

 Mark                            mailto:m...@mailmt.com



Myakka Communications

www.Myakka.com<https://www.Myakka.com>



------



Thursday, April 20, 2023, 10:52:37 AM, you wrote:


Let us know how that goes - I was just looking at the 2116 myself.

On Thu, Apr 20, 2023 at 10:40 AM Mark - Myakka Technologies 
<m...@mailmt.com<mailto:m...@mailmt.com>> wrote:

Mike,



I think I'll have to upgrade to v7 and a some 2216 units.  Guess it is time to 
try to integrate some v7 units into the v6 network and see what happens.





--

Best regards,

 Mark                            mailto:m...@mailmt.com



Myakka Communications

www.Myakka.com<https://www.Myakka.com>



------



Thursday, April 20, 2023, 10:10:32 AM, you wrote:


Years ago on ROX v6 on a 1036, it would take 5 - 10 minutes for /ip route print 
to reflect an upstream change and then another 5 - 10 minutes for the traffic 
to actually change directions.


-----
Mike Hammett
Intelligent Computing Solutions<http://www.ics-il.com/>

Midwest Internet Exchange

The Brothers WISP



<https://www.facebook.com/ICSIL>
________________________________
From: "Josh Luthman" <j...@imaginenetworksllc.com>
To: "AnimalFarm Microwave Users Group" <af@af.afmug.com>
Sent: Wednesday, April 19, 2023 12:25:14 PM
Subject: Re: [AFMUG] BGP Question
I want to say my old x86 would do full tables in 3 minutes...that's been a 
while.

I think the CCR1009/1036/1072 is a couple of minutes, I don't think it's 10-15 
though.

On Wed, Apr 19, 2023 at 11:20 AM Mark - Myakka Technologies <m...@mailmt.com> 
wrote:
Dennis,

Using mikrotik routers.

Two MaxxWave x86 i5 8 core 10 years old v6.47.9

One CCR1072 v6.47.9

Yes taking full tables.

Tried BFD  while back.  Didn't seem that my upstream was supporting it.  Never 
established a session.

Thinking I may need to start looking at new hardware and v7.  But before I go 
that route, what should I expect if I do get 3 brand new CCR2116-12G-4S+ 
running v7.


--
Best regards,
 Mark                            mailto:m...@mailmt.com

Myakka Communications
www.Myakka.com

------

Wednesday, April 19, 2023, 11:08:45 AM, you wrote:

DB> Really depends on a lot of things.

DB> 1.What router are you using?
DB> 2. Are you taking full tables from all of your upstreams?
DB> 3. Are you not using BFD ?
DB> 4.  What version of RouterOS are you using?

DB> V7 will be faster, 2216 will be faster than a 1036, your hold time is kinda 
long..


DB> Dennis Burgess, Mikrotik Certified Trainer
DB> MTCNA, MTCRE, MTCWE, MTCTCE, MTCINE, MTCSE, HE IPv6 Sage, Cambium ePMP 
Certified
DB> Author of "Learn RouterOS- Second Edition"
DB> Link Technologies, Inc -- Mikrotik & WISP Support Services
DB> Office: 314-735-0270  Website: http://www.linktechs.net
DB> Need to Automate MikroTik Backups:  https://cloud.linktechs.net
DB> Create Wireless Coverage's with www.towercoverage.com

DB> -----Original Message-----
DB> From: AF <af-boun...@af.afmug.com> On Behalf Of Mark - Myakka Technologies
DB> Sent: Wednesday, April 19, 2023 9:48 AM
DB> To: af@af.afmug.com
DB> Subject: [AFMUG] BGP Question

DB> We have two circuits coming into our NOC.  We peer with 3 different 
providers on each circuit.  If a circuit fails, BGP will do it's magic and 
traffic will start flowing though the surviving circuit.

DB> However, we seemed to get about 5 - 10 minutes of unstable Internet while 
this is happening.  Is this normal? If not, what can I do to speed up the 
process?  Is it a function of my routers having to rebuild routes?  Will new 
faster routers help?  Is it a function of timers?  Keep-Alive is 30s and hold 
is at 90s.  Should I investigate BFD?

DB> How fast could I expect to get this fail-over to work under best conditions?

DB> Thanks,
DB>  Mark                          mailto:m...@mailmt.com

DB> Myakka Communications
DB> 
https://imsva91-ctp.trendmicro.com:443/wis/clicktime/v1/query?url=www.Myakka.com&umid=08E7599C-F9B1-CC05-BF9C-94CA5B14AB1B&auth=079c058f437b7c6303d36c6513e5e8848d0c5ac4-1a5796e3447e2e1707012b957aa10dd6970458d5


DB> --
DB> AF mailing list
DB> AF@af.afmug.com
DB> http://af.afmug.com/mailman/listinfo/af_af.afmug.com



--
AF mailing list
AF@af.afmug.com
http://af.afmug.com/mailman/listinfo/af_af.afmug.com

--
AF mailing list
AF@af.afmug.com
http://af.afmug.com/mailman/listinfo/af_af.afmug.com

--
AF mailing list
AF@af.afmug.com
http://af.afmug.com/mailman/listinfo/af_af.afmug.com
-- 
AF mailing list
AF@af.afmug.com
http://af.afmug.com/mailman/listinfo/af_af.afmug.com

Reply via email to