Damn near every tall tower I've done straight up the legs and zip tied
right onto the legs.

Grab shielded cabling and do it again, I bet you have water in the line.
Double check your connectors at the bottom for corrosion or water.


Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373

On Tue, Apr 21, 2015 at 3:05 PM, Eric Muehleisen <ericm...@gmail.com> wrote:

> A while back there was a thread about issues running CAT5 cables along the
> entire length of solid steel tower legs.
>
> We've run into a problem where we can't run 100baseT reliably on a couple
> APs. CRC errors will go away if we force the switch port to 10baseT.
> Interestingly enough, packet loss amplifies when it rains.
>
> Any help would be appreciated.
>
>
> --
> Sent via mobile
>

Reply via email to